5
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A
time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes
in accordance with the electrical rating of this unit as specified on the serial/rating plate
located inside the unit near the field wiring compartment.
• Electrical ground is required on this Range Hood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other
materials, DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral
or grounding circuit could result in electrical shock.
• Check with a qualified electrician if you are in doubt as to whether the Range
Hood is properly grounded.
• Failure to follow electrical requirements may result in a fire.
WARNING
!!!!
Содержание BREVA PRO 11
Страница 6: ...6 RANGE HOOD DIMENSIONS 36 30...
Страница 12: ...12 VENTING METHOD REAR OR TOP VENTED Horizontal Vertical 8 8 Rear 8 Go to Pg 13 Go to Pg 14...
Страница 13: ...13 MOUNT THE DAMPER INTO THE HOOD 1 Attach the Damper E with 4 screws G Top position...
Страница 16: ...16 IMPORTANT Attach the 4 previously removed screws to lock the motor in rear place 5...
Страница 17: ...17 1 2 Attach the spacer F with a screw G Attach the cap M MOUNT THE SPACER ONLY FOR BREVA 30 G F M...
Страница 38: ...991 0636 908_02 210118 D00007291_01...