Faber BREVA PRO 11 Скачать руководство пользователя страница 4

4

ALL  WALL  AND  FLOOR  OPENINGS  WHERE  THE  Range Hood  IS  INSTALLED  MUST  

BE  SEALED.

This Range Hood requires at least 24" of clearance

 between the bottom of the Range Hood 

and the cooking surface or countertop. This hood has been approved by UL at this distance 
from the cooktop. 
This minimum clearance may be higher depending on local building codes. For gas cooktops 
and combination ranges, a minimum of 30" is recommended and may be required.
Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking 
surface or countertop. Consult the cooktop or range installation instructions given by the 
manufacturer before making any cutouts.
MOBILE HOME INSTALLATION The installation of this Range Hood must conform to the 
Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly 
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See 
Electrical Requirements"

• Venting system MUST terminate outside the home.
• 

DO NOT

 terminate the ductwork in an attic or other enclosed space.

• 

DO NOT

 use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.
• 

DO NOT

 obstruct the flow of combustion and ventilation air.

• Failure to follow venting requirements may result in a  fire.

   WARNING

!!!!

VENTING   REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either 
through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to pro-
vide efficient performance.  The size of the ductwork should be uniform.  Do not install two 
elbows together.  Use duct tape to seal all joints in the ductwork system.  Use caulking to seal 
exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air 
turbulence that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making 
cutouts.  Do not cut a joist or stud unless absolutely necessary.  If a joist or stud must be cut, 
then a supporting frame must be constructed. 

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside 
– Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, 
or garages. 

Cold Weather installations

An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic 
thermal break should be installed to minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal break. The break should be as close 
as possible to where the vent system enters the heated portion of the house.

3.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other 
hidden utilities.

4.

Ducted fans must always be vented to the outdoors.

Содержание BREVA PRO 11

Страница 1: ...BREV301SS600 BREV368SS600 Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien Instrucciones de instalaci n Informaci n de uso y cuidado BREVA PRO 11...

Страница 2: ...R ONLY FOR BREVA 30 17 Recirculation instructions 18 Mounting on the wall 19 Installation for Mounting Under the Cabinet 23 Connecting house power 25 Operating the controls 26 CFM adjustment 295CFM 29...

Страница 3: ...department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fa...

Страница 4: ...end either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimum to pro vide efficient performance The size of the ductwork should be uniform Do...

Страница 5: ...ear the field wiring compartment Electrical ground is required on this Range Hood If cold water pipe is interrupted by plastic nonmetallic gaskets or other materials DO NOT use for grounding DO NOT gr...

Страница 6: ...6 RANGE HOOD DIMENSIONS 36 30...

Страница 7: ...INSTALLATION HEIGHT REQUIREMENTS MIN 24 OVER ELECTRIC MIN 30 OVER GAS Min 24 Min 30 TOOLS NEEDED TOOL Tape Measure Pencil Electric Drill with 5 16 Drill Bit Phillips Screwdriver Metal sheers Work glov...

Страница 8: ...C Grease filters 2 E Damper 1 F Spacer 1 REF PART G Pozi Screws 1 8 x 3 8 5 I Pozi Screws Screws 3 16 x 1 15 16 4 L Pozi Screws Screws 3 16 x 1 3 4 4 N Wall brackets 2 M Cap 1 PARTS INCLUDED BREVA30...

Страница 9: ...B C ACCESSORIES AVAILABLE ACCESSORY SKU TELESCOPIC PRO CHIMNEY 30 TELEPRO30 TELESCOPIC BACKSPLASH 30 BACK30 DUCTLESS KIT 30 DUCTGRT304 CHARCOAL FILTER FILTER6 FIXED WIRING BOX WIREBOX2 REMOTE CONTROL...

Страница 10: ...se rails 2 C Grease filters 3 E Damper 1 REF PART G Pozi Screws 1 8 x 3 8 4 I Pozi Screws Screws 3 16 x 1 15 16 4 L Pozi Screws Screws 3 16 x 1 3 4 4 N Wall brackets 2 PARTS INCLUDED BREVA36 PARTS NEE...

Страница 11: ...B C ACCESSORIES AVAILABLE ACCESSORY SKU TELESCOPIC PRO CHIMNEY 36 TELEPRO36 TELESCOPIC BACKSPLASH 36 BACK36 DUCTLESS KIT 36 DUCTGRT364 CHARCOAL FILTER FILTER6 FIXED WIRING BOX WIREBOX2 REMOTE CONTROL...

Страница 12: ...12 VENTING METHOD REAR OR TOP VENTED Horizontal Vertical 8 8 Rear 8 Go to Pg 13 Go to Pg 14...

Страница 13: ...13 MOUNT THE DAMPER INTO THE HOOD 1 Attach the Damper E with 4 screws G Top position...

Страница 14: ...cting to the back Unscrew the 8 screws 4 on top 4 on the back and remove the two duct plates on the top and back of the hood Attach the plate removed previously on the top and now the open plate is on...

Страница 15: ...laps from the damper and attach the damper to the back of the hood with 4 screws Attach the closed metal plate to the top with 4 screws E 4 Remove the 4 screws inside the hood on the Motor support and...

Страница 16: ...16 IMPORTANT Attach the 4 previously removed screws to lock the motor in rear place 5...

Страница 17: ...17 1 2 Attach the spacer F with a screw G Attach the cap M MOUNT THE SPACER ONLY FOR BREVA 30 G F M...

Страница 18: ...h includes charcoal filters DUCTGRT364 2 Duct work must be installed to exhaust the rangehood back into the kitchen either at the top of the cabinet FIGURE 3A or at the face or side of the soffit FIGU...

Страница 19: ...ottom edge of the hood will be located as indicated in the figure that is a minimum of 24 30 above cooking surface Mark the wall where indicated at 17 7 16 above the horizontal line at the bottom of t...

Страница 20: ...20 3 4 E E Hang the hood body onto the wall brackets N Use a level to insure the hood is even on the wall use a screwdriver to adjust the brackets as shown Fully tighten the bracket once level N N...

Страница 21: ...5 16 holes at all the center points marked Insert the purchased Wall brackets in the holes Using the remaining screws to anchor the hood in the holes Attach 4 safety screws L to the back of hood into...

Страница 22: ...22 6 Attach the two grease rails B 8B 7 Attach the grease filters C by inserting the front of the filter into the hood and pushing forward Insert the back of the filter into the grease rail C 8B...

Страница 23: ...6 models and 150 lbs for 48 models When necessary the hood may be installed so that it is supported by the sof fit or cabinet The soffit should be constructed with 2 x4 s Use a level to draw the cookt...

Страница 24: ...m I 3 Mark the wall where indicated Drill directly into 5 16 holes at all the center points marked Insert the purchased Wall brackets in the holes Using the four screws to anchor the hood in the holes...

Страница 25: ...e electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper...

Страница 26: ...ress turns the motor on off at speed one C SPEED 2 A quick press turns the motor on at speed two All LED s flash twice alarm activated All LED s lit for 1 second alarm deactivated D SPEED 3 A quick pr...

Страница 27: ...hould be washed The alarm turns on after 100 hours of operation Charcoal Filter Alarm if the alarm is activated the speed two and intensive lights will blink This means the Charcoal filters should be...

Страница 28: ...with the IOT Faber system Then follow the instructions to add a new device and register your home wireless router If the procedure is not successfully completed within a few minutes stop the set up p...

Страница 29: ...grease filters near the rating label for inspection and on the front of your installation user manual 6 To confirm your setting for inspection T1 and T2 buttons will always operate the hood at the sam...

Страница 30: ...er 395 CFM label inside the hood behind the grease filters near the rating label for inspection and on the front of your installation user manual 6 To confirm your setting for inspection the intensive...

Страница 31: ...ud app is available on iOS devices using iOS 11 0 or later or Android devices using Android version 8 or later Visit the Apple App Store or Google Play Store for more information Your range hood will...

Страница 32: ...and should not be used to clean finished surfaces Stainless Steel finish cleaning instructions Clean exterior surfaces with a commercially available stainless steel cleaner The remote control replicat...

Страница 33: ...nit and at the same time pulling downward 2 Wash the filter without bending it leave it to dry thoroughly before replacing if the surface of the filter changes color over time this will have absolutel...

Страница 34: ...at the same time pulling downward 2 Remove the saturated Activated Charcoal Filters as indicated A 3 Fit the new Filters as indicated B 4 Replace taking care to ensure that the handle faces forwards C...

Страница 35: ...35 WIRING DIAGRAM UHDWLRQ GDWH 5 RUUDGR UHDWHG E RGH 0 9 1 9DF 5 1 2 6 7521 7516 250 5 1 5 7 9 7 5 5 0 9 02725 5 25 8 31 7 7 8 8 DEHU 7 8 7 7 5 5 5 25 5 5 5 5 5 5 5 5 9 7 5 25 8 25 8 7 5 5 5 25...

Страница 36: ...outside the United States Canada or Latin America including any non UL or C UL or non NOM approved Franke Faber range hoods are excluded from Warranty coverage Expenses for travel and transportation...

Страница 37: ...low All warranty claims must include the following for processing 1 Proof of purchase from Franke or Faber Authorized Retailer 2 Original purchaser s name address included city state zip email address...

Страница 38: ...991 0636 908_02 210118 D00007291_01...