48
E - INTENSIVE LEVEL 1 -
A quick press will
operate intensive speed level 1 for 6 minutes.
INTENSIVE LEVEL 2 -
A 2 - second press
will
operate intensive speed level 2 for 6 minutes.
At the end of the 6 minutes the hood returns
to the speed that was set before. If intensive
is set with the motor turned off, the hood will
turn off after 6 minutes.
BUTTON
FUNCTION
INDICATOR
Grease Filter Alarm
- If the speed two and
intensive buttons are lit, this means the
Grease Filter saturation alarm is activated
and the grease filters should be washed. The
alarm turns on after 100 hours of operation.
Charcoal Filter Alarm -
if the alarm is
activated, the speed two and intensive lights
will blink. This means the Charcoal filters
should be replaced AND the grease filters
should be washed. The charcoal filter alarm
turns on after 200 hours of operation.
Heat Sensor Information -
The hood is equipped with a
temperature sensor which, if the motor is off and the temperature
below the stove is high, activates the motor at maximum speed.
The condition is indicated by the blinking of Speed 1 and 2 LED’s
, Speed 3 LED is lit. This condition persists until the temperature
returns below the threshold. It is possible to exit this mode by
selecting one of the speeds.
Содержание BREV368SS600
Страница 6: ...6 RANGE HOOD DIMENSIONS BREVA30 30...
Страница 7: ...7 BREVA36 36...
Страница 8: ...8 BREVA48 48...
Страница 34: ...34 1 2 Attach the spacer F with a screw G Attach the cap M MOUNT THE SPACER ONLY FOR BREVA 30 G F M...
Страница 37: ...37 BREVA 48...
Страница 43: ...43 TOP DIMENSION BREVA36 TOP DIMENSION BREVA48...
Страница 44: ...44 1 2 Attach the Hood Body with 4 screws I from the bottom Lift the hood to the cabinet I...
Страница 59: ...59...
Страница 60: ...991 0636 908_02 210118 D00007291_01...