Intermediate stirring
options during cooling
The control cabinet has a function allowing the agitator to be switched on
manually. This can be done is different ways.
Regardless of the option chosen, the corresponding LED always
indicates when the agitator is operating.
The function is set at configuration level using parameter [P81].
Parameter [P81] is set to 1:
"Intermediate stirring SHORT or LONG" can be switched on via the
regulator's foil keyboard. In this case:
!
Intermediate stirring SHORT =
Press agitator button for approx. 1 sec. until "Sho" appears in the
display. Release the button immediately, otherwise "Intermediate
stirring LONG" will be activated.
!
Intermediate stirring LONG =
Press agitator button for approx. 3 secs. until "Lon" appears in
the display.
The duration of SHORT or LONG stirring is fixed at settings level using
parameters [C50] and [C51].
Parameter [P81] is set to 2:
not used.
Parameter [P81] is set to 3:
On request the control can be set for "continuous stirring", i.e. the
agitator can be switched on and off by pressing a button.
When the agitator is switched on or off, the display briefly indicates "ON"
or "OFF".
a.
b.
c.
"Continuous stirring"
in OFF mode
In OFF mode, "continuous stirring" can be selected by pressing the
agitator button, and switched off again by pressing the "STOP" button.
During continuous stirring the agitator LED lights up, and a rotating bar is
shown in the display.