Configuration level 
operation

This level is for configuring the regulator's basic functions.

To prevent interference by the end user, access 
is made even more complex.

Switching to configuration level:

!

Press button 

Arrow UP

 and 

Arrow DOWN

 

simultaneously for approx. 5 seconds.

!

The first parameter [C1] appears in the display.

!

Press button 

Arrow UP

 repeatedly until the last 

parameter [C99] at working level is reached.

!

Press button 

Arrow UP

 again and hold down until [Pb] 

appears in the display.

!

When [Pb] appears, hold down button 

Arrow UP

 and 

simultaneously press button 

Arrow DOWN

 for approx. 

3 seconds.

!

The display then shows the first parameter [P5] in the 
configuration level.

Meaning of parameters

Param. P5: Function K1 in event of sensor failure
Param. P6: Function K2 in event of sensor failure

The switching status of the relay contacts 
can be set for the event of a sensor failure.
0 = OFF in the event of failure
1 = ON in the event of failure

Parameter P10: Hyst. mode for target temperature T1
Parameter P11: Hyst. mode for target temperature T2

(with reference to the compressor relay)

0 = symmetrical
1 = one-sided

The hysteresis determines the 
value by which the temperature 
of the medium may deviate from 
the corresponding target tempe-
rature before the relay contact is 
activated. See diagram.

If the contact in question is for 
cooling, the hysteresis is always upwards. In the case of 
heating contacts it is below the target temperature (cooling 
or heating contact is set at configuration level).

In the "symmetrical" hysteresis mode, the value selected is 
distributed on both sides of the target temperature.

Param. P20: Limit for target temperature T1 downwards
Param. P21: Limit for target temperature T1 upwards
Param. P22: Limit for target temperature T2 downwards
Param. P23: Limit for target temperature T2 upwards

Setting of input limits for target temperatures at working and 
programming levels.

Range: -10 .. 99°C

one side

Hysteresis

symetrical

Hysteresis

Target-
temp.

Target-
temp.

K2 K1

P

C

P

R

STOP

SET

4°/8°

Operation overview for configuration level

P5

P6

P10

P11

P20

P21

P22

P23

P30

P31

P32

P33

P70

P71

P80

P81

Sensor failure
function K1

Hysteresis-
mode for T1

Limit for target-
temp. T1 downw.

Limit for Hyst. 1
downwards

Min. action time
Compr. K1

Min. pause time
Compr. K1

Switching
T1 to T2

Mode intermitt.
stirring

1

1

0

10

0

20

0,1

0,1

0

0

2

2

0

1

1

1

Press button

 and 

simultanously

Press

button

SET

Display

setting

Altering

setting

Factory

setting

To switch back to the working level:

Press for 5 seconds simultaneously

(Switches back automatically after 30 seconds.)

Switching to configuration level: see description

Sensor failure
function K2

Hysteresis-
mode for T2

Limit for target-
temp. T2 downw.

Limit for target-
temp. T1 upw.

Limit for target-
temp. T2 upw.

Limit for Hyst. 2
downwards

Limit for Hyst. 1
upwards

Limit for Hyst. 2
upwards

P99

Temperature
scale

or

SET

or

SET

0

Содержание Dari-Kool 720011

Страница 1: ...2016 Installation and Operation Manual Control for milk cooling tanks COMPACT KOOL ...

Страница 2: ...tion Page 9 Programming level operation Page 10 Configuration level operation Page 11 Intermediate stirring options during cooling Page 13 Continuous stirring in OFF mode Page 13 Setting the actual value correction Page 14 Fault indication on the display Page 14 General measures when using electronic control systems Page 15 Guarantee Page 17 Circuit diagramm without engineprotect XX 1 Page 18 Circ...

Страница 3: ...y pressing a button Cooling mode Press the 4 8 button the compressor and agitator operate automati cally In between cooling periods agitator and compressor LEDs off intermediate stirring can be activated Stirring mode If stirring mode is active temperature shown in display Short intermediate stirring Briefly press the Agitator button sho appears in the display and the agitator starts to operate Lo...

Страница 4: ...ice must not be installed in potentially explosive atmospheres The control cabinet for milk cooling tanks fulfils the EC requirements for electromagnetic compatibility EMC and the Low Voltage Directive LVD The safety components meet the VDE regulations Safety These operating instructions contain important technical and safety information Please read them carefully before installation and before wo...

Страница 5: ...f it is necessary to shorten or lengthen the sensor cable on installation or if a sensor other than the one supplied is to be fitted the actual value correction parameter must be adjusted accordingly See the section Setting the actual value correction on page 14 Observe the permitted temperature range to which the sensor is suited Elektrical connections Sensor cable PVC Silicon temperature range C...

Страница 6: ...witching contactor and motor protection switch 2 make contacts 16A AC 1 250 V 13 mm LED Display 3 digits 0 1 C 1 0 C two step controller 50 150 C 0 1 to 99 9 K free adjustable standard adjusting 0 7 K cooling see sketch IP 64 Screw terminals 20 to 70 C 0 to 50 C 75 no condensation Specifications subject to change without prior notice Sensor element Bush material Bush length Bush diameter Cable mat...

Страница 7: ... of the regulator are set As subsequent interventions by the end user after the parameters have been set can result in dangerous chan ges to functions which might not be immediately obvious access to the configuration level is even more complex Operation overview The milk is cooled to the selected target temperature 4 or 8 The adjusted target temperature is displayed by LED 4 or 8 The stirrer runs...

Страница 8: ...ckly Release button SET To store the changed parameter in the memory first release the arrow button and then button SET Switching back to working level possible from any parameter Press button Arrow UP and Arrow DOWN simultaneously for approx 5 seconds The current actual value appears in the display If at programming or configuration level no buttons are pressed for approx 1 minute the regulator s...

Страница 9: ...rds or downwards Button Agitator in cooling mode press for appr 1 sec SHORT intermediate stirring press for appr 3 sec LONG intermediate stirringSee also the section describing the intermediate stirring options page 13 Button Agitator in OFF mode continuous stirring Press the Agitator button together with button SET in cooling mode to adjust the current target temperature upwards Button STOP therm...

Страница 10: ...on after being turned off Parameter C50 Duration of SHORT intermittent stirring Duration min of stirring after short pressing of the intermittent stirring button Parameter C51 Duration of LONG intermittent stirring Duration min of stirring after longer pressing of the intermit tent stirring button Parameter C91 Sensor correction The sensor reading can be provided with a corrector which works cumul...

Страница 11: ...the hysteresis is always upwards In the case of heating contacts it is below the target temperature cooling or heating contact is set at configuration level In the symmetrical hysteresis mode the value selected is distributed on both sides of the target temperature Param P20 Limit for target temperature T1 downwards Param P21 Limit for target temperature T1 upwards Param P22 Limit for target tempe...

Страница 12: ...ng of minimum pause time for compressor relay contacts K1 in order to prevent repeated switching on and off Range 0 0 999 seconds Parameter P80 Switch from target temperatur T1 to T2 Setting of funktion switching target temperature 0 not possible 1 with button 2 do not use Parameter P81 Function intermittend stirring Setting of funktion start manual intermittend stirring See section Intermediate s...

Страница 13: ...ediately otherwise Intermediate stirring LONG will be activated Intermediate stirring LONG Press agitator button for approx 3 secs until Lon appears in the display The duration of SHORT or LONG stirring is fixed at settings level using parameters C50 and C51 Parameter P81 is set to 2 not used Parameter P81 is set to 3 On request the control can be set for continuous stirring i e the agitator can b...

Страница 14: ...r C91 Actual value correction must then be adjusted at programming level Memory fault Faulty regulator Remove the regulator and send it for repair Measurement range exceeded The maximum measurement range of the sensor has been exceeded LED Display F1 F2 F3 FFF The regulator is adjusted to the selected sensor in the factory When replacing a faulty sensor use only the same type In order to adjust th...

Страница 15: ...m However in practice this is possible only with difficulty as even a normal contactor without interference suppres sion produces interference pulses of up to 3 0 kV For this reason we recommend that the following principles be taken into account during installation Try to eliminate all sources of interference by carrying out interference suppression and minimising the interference level Radio int...

Страница 16: ... example be limited by using self induction diodes varistors or suppresser diodes The diagram on the left shows one possibility using a self induction diode AC voltage In the case of a c voltage interference suppression as described above is not possible Instead an RC combination must be used An RC filter must be connected as directly as possible to the inductance in order to ensure a short line I...

Страница 17: ...The use of zero voltage switches is also recommended The suggestions made represent only a few of the possible ways of protecting a microprocessor controlled regulator system from interfer ence The suggested measures have the advantage that they will increase the lifetime of the devices as lower induction voltages redu ced spark formation will also reduce contact burn f Every regulator is individu...

Страница 18: ... 0 1691 627200 Fax 44 0 1691 627222 Email sales fabdec com Fabdec GmbH Gerhardstrasse 5 45892 Gelsenkirchen Germany Tel 49 0 209 700 900 Fax 49 0 209 70090 20 Email germany fabdec com Fabdec LLC October Embankment 12 building 2 193091 Saint Petersburg Russia Tel 7 812 715 0102 or 7 921 977 5936 Email russia fabdec com ...

Отзывы: