background image

Fabco Power 

 

 

Instruction Manual 

• 

Page 7 

  

 

 

PARTS BREAKDOWN 

HYDRO 350X5

0 hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  No. PART #  DESCRIPTION 

 

 

1  572262  Louvered Panel 

   

 

  2  572308  Frame For Stator 

   

 

  3  572182  Drive End Bell 

   

  3 a 572265  Screen 

   

  4  572235  Front Bearing 

   

  5  572184  Fan 

   

  6  572307  Rotor 

   

  8  572064  Rear Bearing 

 13  572186  User Terminal Board 

 15  572260  Cover 

 17  572195  Capacitor 25 mfd/w Tie Wraps 

 19  572189  Diodes 

   

 20  572615  Pump Mount 

 21  572066  Coupling 24mm 

   

 

 22  572067  Spider 

   

 23  572068  Coupling ½   

   

 24  572173  Motor w/Flow Control 

   

 25  572128  Rails 

   

 26  572154  Mounts 

 27  572206  Flow Control Cartridge 

 

 28  572261  Stud Cover 

 

PART #  OPTIONAL CONTROL PANEL

 

 29  572263  Rubber Cup 

  572227  Complete Control Panel 

 30  572272  Fan Ring 

  572161  Receptacle 120/240 Volt  

    572072  Seal For Hydraulic Motor 

  572093  Volt Meter 220 volt  

    572306  Generator Complete 

  572052  Volt Meter 120 volt  

     

 

   572161  Receptacle 120/240 Volt 

    572159  Voltage Indicating Light 

  572100  Waterproof Recpt. Cover 

    572365 Overload Protection Device ca-15       572226  GFI Outlet 120 Volt 

Содержание HYDRO 350X-50HZ

Страница 1: ...er Instruction Manual for Model HYDRO 350X 50HZ 2 WIRE Hydraulic Generator Manufacturing of Vehicle Mounted Generators Hydraulic Generators P O Box 582 Chester NY 10918 845 469 9151 Fax 845 469 7871 W...

Страница 2: ...120 240 MOTOR STARTING 300 SURGE VOLTAGE REGULATOR INHERENT OUTPUT 3500 WATTS CONTINUOUS AT 100 F OIL TEMPERATURE HYDRAULIC MOTOR GEAR TYPE WITH BUILT IN FLOW CONTROL FLOW CONTROL PRESSURE COMPENSATIO...

Страница 3: ...gh back pressure can be caused by spikes sent back through the return from other equipment on a common return line Another potential problem can develop if several pieces of equipment are connected to...

Страница 4: ...cal load on the generator By using this setting you will have approximately 50HZ cycles or 3000 RPM when you are running at full rated load One way this can be accomplished is by using a Photo Tachome...

Страница 5: ...at the load Drive motor speed control systems generally have a small drop in speed between no load and loaded conditions We therefore recommend setting no load speed 3 4 above nominal speed CHECKING V...

Страница 6: ...OV25 ERLOAD SELF RE SETTING GROUND SCREW ON GENERATOR FRAME USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS U2 V2 V1 W1 CONNECT NEUTRAL TO GROUND IF USING GFCI OUTLETS NEUTRAL WHITE 240 RED OR BLACK W...

Страница 7: ...572066 Coupling 24mm 22 572067 Spider 23 572068 Coupling 24 572173 Motor w Flow Control 25 572128 Rails 26 572154 Mounts 27 572206 Flow Control Cartridge 28 572261 Stud Cover PART OPTIONAL CONTROL PA...

Страница 8: ...lace LOW NO LOAD VOLTAGE 1 Speed too low 2 Faulty rotary diodes 3 Breakdown in windings 4 Capacitor with high capacity 1 Check and adjust RPM s 2 Check and replace 3 Check winding resistance as per ta...

Страница 9: ...INE FILTER 8 OIL COOLER 9 HYDRAULIC FLUID RESERVOIR Some units may be equipped with integral priority flow control refer to specific model number External case drain line may be required on some units...

Страница 10: ...Fabco Power Instruction Manual Page 10 BRUSHLESS GENERATOR WIRING...

Страница 11: ...Fabco Power Instruction Manual Page 11 HYDRAULIC MOTOR HOSE HOOK UP Fabco Power...

Страница 12: ...Fabco Power Instruction Manual Page 12...

Страница 13: ...Fabco Power Instruction Manual Page 13...

Отзывы: