3.3  ELECTRIC CONNECTIONS

3.3  ELECTRICAL CONNECTIONS

3.3.1  RADIO VERSION

3.3.2  WIND VERSION

a

220 V ~

220 V ~

a

b

YELLOW-GREEN

BLUE

BROWN

PHASE

NEUTRAL WIRE

PUSH-BUTTON

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL 

ONLY:

 For this type of configuration, connect the blue and 

brown cables of the motor to the mains power supply and 

the yellow-green cable to earth. 

Do not connect the RED 

(or black) wire.

   Do not cut the red (or black) cable if it is not 

used, just insulate it

AUTOMATED SYSTEM CONTROLLED BOTH BY REMOTE 

CONTROL AND BY PUSH-BUTTON:

  For  this  type  of 

configuration, connect the motor as shown in the previous 

diagram, fig. 6.

  

The push-button has a step-by-step logic: 

each pressure exerted on the push-button 
sends a pulse to the motor (I.E.: FIRST PULSE UP 
- SECOND PULSE STOP - THIRD PULSE DOWN etc.). 
After a down or up command, the motor stays 
active until the relevant travel limit has been 
reached.

The series R tubular motor can be controlled both by the 

remote  control  and  by  a  push-button  with  step-by-step 

logic.

The series W tubular motor can be controlled both by the 

remote  control  and  by  a  push-button  with  step-by-step 

logic. In addition, a wind sensor (anemometer) can be 

connected to the motor: it commands the 

closure of the 

rolling shutter 

as soon as the wind has reached a speed 

higher than 20 Km/h. 

  

WHEN THE ANEMOMETER OPERATES, THE MOTOR 

DIRECTION OF ROTATION CORRESPONDS TO THAT 
CONTROLLED BY THE UP PUSH-BUTTON OF THE 
REMOTE CONTROL.      THE DOWN COMMAND IS 
INHIBITED FOR 16 min.

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL 

AND ANEMOMETER:

 For this type of configuration, connect 

the blue and the brown wire of the motor to the mains 

power, and the yellow-green wire to earth. Do not connect 

the red (or black) wire.

THE ANEMOMETER must be connected as shown in figure 7.

 

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL, 

PUSH-BUTTON AND ANEMOMETER:

  For  this  type  of 

configuration, connect the motor as shown in the diagram 

of figure 7.

Fig.6

Fig.7

YELLOW-GREEN

BLUE

BROWN

RED

(OR BLACK)

PUSH-BUTTON

WHITE

ANEMOMETER

  

The push-button has a step-by-step logic: 

each pressure exerted on the push-button 
sends a pulse to the motor (I.E.: FIRST PULSE UP 
- SECOND PULSE STOP - THIRD PULSE DOWN -etc.). 
After a down or up command, the motor stays 
active until the relevant travel limit has been 
reached.

   Do not cut the red (or black) cable if it is not 

used

.

RED

OR BLACK

PHASE

NEUTRAL WIRE

Содержание T-MODE TM R

Страница 1: ...T MODE TM R W 868 Mhz ...

Страница 2: ...force 7 The power mains of the automated system must be fitted with a multi pole power switch with a switch contact gap of at least 3 mm 8 The min installation height for the automated system is 2 5 m 9 Make sure that a differential switch with trip threshold of 0 03 A is fitted upstream of the system 10 11 Use only FAAC original parts for maintenance 12 The equipment handling must always be at si...

Страница 3: ... 16 45 570 IP44 15 17 15 20 4 17 230 50 180 0 8 16 45 670 IP44 25 17 20 20 4 17 230 50 250 1 1 16 45 670 IP44 30 17 30 20 4 17 230 50 250 1 1 28 45 670 IP44 35 12 35 20 4 12 230 50 250 1 1 28 45 670 IP44 45 12 45 20 4 12 230 50 270 1 2 28 45 670 IP44 50 12 50 20 4 12 230 50 300 1 5 28 45 670 IP44 T MODE TUBULAR MOTORS WITH RADIO AND WIND 433MHz a Tubular motor b Example of wheel adapter Accessory ...

Страница 4: ...th a drill Ø 3 mm on the roller Fig 3 ref b at the distance A previously measured on the tubular motor Fig 3 ref a 3 Fit the assembled tubular motor inside the roller from the side opposite the cap until the crown adapter is completely inside the roller Fig 4 ref a 4 Secure the wheel adapter to the roller with a tapping screw 4x10 fitted in the previously drilled hole as shown in figure 4 ref b 5 ...

Страница 5: ... control and by a push button with step by step logic In addition a wind sensor anemometer can be connected to the motor it commands the closure of the rolling shutter as soon as the wind has reached a speed higher than 20 Km h WHEN THE ANEMOMETER OPERATES THE MOTOR DIRECTION OF ROTATION CORRESPONDS TO THAT CONTROLLED BY THE UP PUSH BUTTON OF THE REMOTE CONTROL THE DOWN COMMAND IS INHIBITED FOR 16...

Страница 6: ...dy stored in the memory the motor moves for 1 second in both directions 2 Press the RISE key within 5 seconds and press the DESCENT Key within the next 5 seconds the motor moves in both directions for 1 second 3 Press the RISE push button of the NEW transmitter within 5 seconds If the new transmitter was correctly memory stored the motor moves in both directions for 1 second 4 If the memory storag...

Страница 7: ... minus sign to reduce it 5 3 ADJUSTMENT OF RISE TRAVEL LIMIT STOP RELEVANT TRAVEL LIMIT STOP RELEVANT TRAVEL LIMIT STOP 1 Hold down the rise push button 2 Using the adjustment tool Fig 1 ref e turn the screw of the travel limit stop corresponding to the roller s rise rotation direction Fig 12 ref a toward the plus sign to increase the travel of the roller shutter or toward the minus sign to reduce...

Страница 8: ...ebush Sydney Australia tel 61 2 87565644 www faac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440 www faac ch CHINA FAAC SHANGHAI Shanghai China tel 86 21 68182970 www faacgroup cn NORDIC REGIONS FAAC NORDIC AB Perstorp Sweden tel 46 435 779500 www faac se POLAND FAAC POLSKA SP ZO O Warszawa Polan...

Отзывы: