WARNINGS FOR THE INSTALLER

DECLARATION OF CONFORMITY

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Calari, 10  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

Operator mod. TM 45 radio    -      433Mhz

 

•  conforms to the essential requirements of the following EEC directives:

  

- 2006/95/EEC

 

  - 2004/108/EEC

 

  - 99/05/EEC

 

•  it thus conforms to the following harmonised standards:

 

  - EN 60335-1-95, EN60335-2- 97/10-2000.

 

  - EN 61000-3-2, EN61000-3-3, 

 

  - EN55014-1, EN55014-2

 
 

    

 
 

Bologna, 01/12/2012 

The Managing Director

 

   

A. Marcellan

1.  ATTENTION! To ensure the safety of people, it is important that 

you read all the following instructions. Incorrect installation or 
incorrect use of the product could cause serious harm to people. 
Keep these instructions for future reference.

2.  Carefully read the instructions

  before  beginning  to  install  the 

product.

3.  This  product  was  designed  and  manufactured  exclusively  for 

the purpose indicated in this documentation. Any other use, not 
expressly indicated here, could compromise the good condition/
operation of the product and/or be a source of danger.

4.  FAAC declines any responsibility for improper use or use other than 

that for which the automated system was intended.

5.  Disconnect  the  power  supply  before  any  operation  on  the 

system.

6.  The installation must be carried out by qualified technical personnel 

in conformity with the norms in force.

7.  The power mains of the automated system must be fitted with a 

multi-pole power switch with a switch-contact gap of at least 3 
mm.

8.  The min. installation height for the automated system is 2.5 m.
9.  Make sure that a differential switch with trip threshold of 0.03 A 

is fitted upstream of the system.

10. 
11.  Use only FAAC original parts for maintenance.
12.  The equipment handling must always be at sight.
13.  Do not allow children or adults to stay near the product while 

it is operating.

14.  Keep radio controls or other pulse generators out of reach of 

children, to prevent the automated system from being activated 
unintentionally.

15.  The  automated  system  cannot  be  repaired/adjusted  by  the 

end-user; these operations can only be carried out by qualified 
personnel.

16.  Anything  not  expressly  specified  in  these  instructions  is  not 

permitted.

17.  The setting of the travel stops must be made with the motor installed 

inside the tube (not at the bench).

18.  The equipment is not intended to be used by people (children included) 

without sufficient experience or knowledge, unless they are surveilled or 
instructed on the equipment use by a person responsible for the safety.

19.  Children  must  be  supervised  to  make  sure  they  do  not  play  with  the 

equipment.

20.  In case of outdoor installation install the designated cable H05RR-F with a 

min. carbon percentage of 2% and a min. section of 4 x 0.75 mm².

21.  In the version with radio control the installation of the step button for the 

manual operation in case of radio control problems is mandatory.

Содержание T-MODE TM R Series

Страница 1: ...T MODE TM R W 433 Mhz...

Страница 2: ...force 7 The power mains of the automated system must be fitted with a multi pole power switch with a switch contact gap of at least 3 mm 8 The min installation height for the automated system is 2 5 m...

Страница 3: ...16 45 570 IP44 15 17 15 20 4 17 230 50 180 0 8 16 45 670 IP44 25 17 20 20 4 17 230 50 250 1 1 16 45 670 IP44 30 17 30 20 4 17 230 50 250 1 1 28 45 670 IP44 35 12 35 20 4 12 230 50 250 1 1 28 45 670 IP...

Страница 4: ...h a drill 3 mm on the roller Fig 3 ref b at the distance A previously measured on the tubular motor Fig 3 ref a 3 Fit the assembled tubular motor inside the roller from the side opposite the cap until...

Страница 5: ...control and by a push button with step by step logic In addition a wind sensor anemometer can be connected to the motor it commands the closure of the rolling shutter as soon as the wind has reached a...

Страница 6: ...hs 1 Supply the motor with power 2 Within 15 seconds press the P programming push button then the DOWN push button of the transmitter 3 The motor performs two brief movements in both directions to con...

Страница 7: ...HER REMOTE CONTROLS 433Mhz 1 Supply power to the motor 2 On an already memory stored remote control press the PROGRAMMING push button for 2 seconds and within 5 seconds press the STOP push button 3 On...

Страница 8: ...out making the connection 2 Supply power to the motor after approx 10 seconds the motor operates in both directions for 1 second signalling that the memory has been completely deleted 3 Cut power agai...

Страница 9: ...the adjustment tool turn the screw of the travel limit stop corresponding to the roller s rise rotation direction Fig 12 ref a toward the plus sign to increase the travel of the roller shutter or towa...

Страница 10: ...mebush Sydney Australia tel 61 2 87565644 www faac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440...

Отзывы: