Rapid Guide Resist-SA TAG10 SA ver.1-1 rev. A
2
CONFIGURATION MASTER CODE / MASTER CARD
To start the configuration of the different parameters of the unit Resist SA or TAG10 SA, it is necessary to store first on the unit the master code or
the master card.
As the equipment is provided without master code/master card, the first operation necessary to make will be to store the code/card on the device.
Therefore you need to do as follows:
•
Verify that the 3 frontal led flash simultaneously.
•
Type the code (min. 6 max. 14 characters) than type E, or read the Master card.
•
If the operation has been executed in a correct way, only the amber led on the front panel will be activated
IMPORTANT: it is necessary to keep the memorised master code or master card in a safe place as it has to be used to execute all the variations of the
control unit configuration.
PROGRAMMING
The programming of all the parameters of Resist SA or TAG 10 SA can be obtained by choosing one of the eight menus available and by typing the
master code or reading the master card. The following table shows the characteristics of the 8 options that can be programmed
Menù
Kind of programming
Commands with Master Code
Commands with Master Card
1
Inputting new users
1 x Master Code E
1 + reading Master Card
2
Cancelling users
2 x Master Code E
2 + reading Master Card
3
Qualification of users
3 x Master Code E
3 + reading Master Card
4
Import data
4 x Master Code E
4 + reading Master Card
5
Export data
5 x Master Code E
5 + reading Master Card
6
Configuration input/output
6 x Master Code E
6 + reading Master Card
7
Configuration reader B
7 x Master Code E
7 + reading Master Card
8
Activation internal /external card reader
8 x Master Code E
8 + reading Master Card
IMPORTANT: the command enables to enter into the relevant menu, in which you can execute all the operations explained consecutively. It is
important to underline that x means button X while E means typing button E.
To get out of the programming mode, you have to type X for at least 4 seconds.
MENU 1 INPUTTING NEW USERS
To input the users in the control unit archive, you have to indicate for each user, the location number of the memory where the relevant code or card
will be stored. Available numbers are from 1 to 500 and, obviously, they can house a single data-item.
•
Enter the function with:
1 x Master Code
E
or with:
-1 then the Master Card reading
•
Type in the
location No.
followed by
x
, then the
user code
and then
E
, or followed by the
card reading.
For example, if you want to store code
2894 in location 23, the command will be:
23 x 2894 E
instead, if you want to store a proximity card in location 37, the command will be:
37 then the Card reading
•
Continue like this and input all the necessary codes/cards, then press key E for at least 4 seconds to exit programming, or read the master card.
NB: we advise you to take a note of the number of the locations and the relevant stored users, so that the code or card can be eliminated after card or
right of access has been lost. The user code must have min 4 and max 6 characters. .
MENU 2 CANCELLING USERS
To cancel users from the control unit archive, you must obviously know the memory location number where the relevant code or card was stored. If
you have the card to be cancelled, just read it after entering the mode.
•
Enter the function with:
2 x Master Code
E
or with:
2 then the Master Card reading
•
Type in the
location No.
of the code/card to be cancelled followed by
E
. If, for example, you wish to cancel the code/card of location 23, the
command will be:
23
•
Continue like this and cancel all the necessary codes/cards, then press key
E
for at least 4 seconds to exit programming, or read the master card.
MENU 3 QUALIFICATION OF USERS
This function enables you to change the access characteristics of a single user or of a group of users. The following can be indicated for every stored
code/card: the activation (output No.) which the control unit must execute, the direction (absent/present), if it is subjected to antipassback
•
Enter the function with:
3 x Master Code
E
or with:
3 then the Master Card reading
•
To execute the required modifications, you must first indicate the
location number
or the
range of locations
where the codes/cards are stored,
then the
command
which varies the characteristics. The following table expresses this concept, where
NNN
or
FFF
are the location number of
the code/card and
C
is the command that changes the parameters.:
Kind of typing
Description
NNN x C
Displays data of code/card stored at NNN location
NNN x FFF x C
Set data for code/card stored from NNN to FFF locations
1111 x C
Set data for all code/card stored
•
The list of available commands and their meaning is explained in the following table:
CommandC Description
Examples
5 Force
“Absent”
37 x 5 = User 37 Absent
6 Force
“Present”
115 x 6 = User 115 Present
7
Force subjected to “Antipassback”
21 x 7 = User 21 Subjected to Antipassback
8
Force not subjected to “Antipassback”
3 x 8 = User 3 Not subjected to Antipassback
11
10
01
00
For reading on A, both output 1 and output 2 are switched on
For reading on A, only output 1 is switched on
For reading on A, only output 2 is switched on
For reading on A, both output1 and output 2 are switched off
23 x 11 = User 23 switch on both outputs
48 x 10 = User 48 switch on output1
57 x 01 = User 57 switch on output2
21 x 00 = User 21 no switch on anything
1111
….
The command sets the enabling of the outputs, with the same
logic defined for reading on A; (see above box).
63 x 1111 = User 63 enables output 1 and output 2
whether reading is on A or B.