Rapid Guide Resist SA TAG 10 SA ver.1-1 Rev. A
Resist SA – TAG 10 SA
RESIST TPS SA
RESIST PS SA RESIST T SA TAG 10 SA
PRODUCT
RESIST-SA (or TAG10-SA) is an access control device able to archive Codes or Cards, in a completely independent manner. The unit can store n°1
Master Code (code or card) and n° 500 User codes (codes or cards). A Master Code must have at least 6 characters and a maximum of 14 characters,
the user codes must have at least 4 and max. 14 characters. If there is no keyboard, a Passive Cards Kit is needed: this kit contains 12 cards which
simulate the use of the keyboard..
IMPORTANT: The device is provided with activation outputs for valid codes and cards. For this reason, we advise you to install it every time in a
protected position . It is possible to connect to this unit a reader without the decision-making unit (max. distance 100 mt.) which can be used for the
gateway control.
CONNECTIONS ELECTRIC SPECIFICATIONS
•
power supply: 12 ÷ 24 Vdc - 12 ÷ 21 Vac
•
consumption at 12 Vdc: 180 mA (without outside
Reader or other loads connected)
•
consumption at 24 Vdc: 120 mA (without outside
Reader or other loads connected)
•
consumption at 12 Vac: 180 mA (without outside
Reader or other loads connected)
•
consumption at 21 Vac: 120 mA (without outside
Reader or other loads connected)
•
5 Vdc output for external reader: max 300 mA
(rated voltage 11.5 Vdc)
•
5 Vdc output for external reader: max 60 mA
•
Relay-1 and Relay-2 contacts: max 1 A at 24 Vdc
•
Buzzer-B output: "open-collector" type without
push-pull diode (max 70 mA at 12 Vdc)
•
Alarm exit: "open-collector" type without push-
pull diode (max 70 mA at 12 Vdc)
•
inputs Inp-1 and Inp-2: to be activated by
connecting to GND and using a 'clean contact'
(e.g.: a Relay)
NB: the power supply unit for the
management unit is not supplied.
MODE
The following options are available:
•
“
No-Master-Code
” mode; You are in this mode when you activate (or reset) the device with the Master-Code” not yet on. This is the status
when the machine is new or after cleaning (Total or MC only). This condition is marked by 3 led flashing at the same time.
•
“
Programming
” mode; there are various programming modes. You cannot change over from one to the other, but you must always return to the
“
Access Control
” mode and then select the new programming.. To enable this function, type in a code consisting
of two parts
separated by the
“
X
” key. : ”
Programming N°
” + “
X
” + “
Master-Code
” (or “
Programming N°
” + “
Master-Card
”). Such condition is indicated by
activation of the yellow led.
•
“
Access
Control
” mode ; You are in this mode when you activate (or reset) the device with the “Master-Code” already on. Openings by
validating the typed codes or cards read are permitted and one can also enter in one of the programming functions. The control unit normally
operates in this way. Such condition is indicated by activation of the red led. When a valid code or card is typed, a green led is activated; when
the typed card/code is not valid, a yellow led is activated for a moment.
+1
2V
GND
D1
-D
AT
D0
-C
LK
BUZ
Z
E
R
-B
+5
V
ING
1
ING
2
ALL
A
RM
E
IN-
A
C
-1
IN-
A
C
-2
RE
LE
1-
A
RE
LE
1-B
RE
LE
2-
A
RE
LE
2-B
LED 5V
RELE’
1
RELE’ 2
1 2 3 4 5 6
12 ÷ 24 Vdc
12 ÷ 21 Vac
Power supply
Input
1 2 3 4 5 6 7 8 9
M2
M1
Reader B terminal
(with 12Vdc power supply)
J6
J5
Ing-
Aux
J1
J6 is for the
"Mem-Exp"
expansion
board (available
as an
accessory)
Open-Collector
Buzzer
To exclude the
buzzer interrupt
the track on
PS2
CPU Board
Alarm output
Door Status
Door opener
Push-button
+5V output
+ G D C B
1 N
2 D
V
Tamper key