23
11.3
Connection of MINIDEC, RP cards
Insert the MINIDEC or RP decoding card in the block connector
J5 (Fig. 7), with the components facing up (Fig. 7 shows the
connection of cards RP433DS).
For programming the decoding cards, consult the individual
instructions.
Mains power present and battery charged.
Mains power not supplied for not more
than 5 minutes, with battery charged.
When mains power returns, the LED stays
lighted steadily.
If mains power is still not supplied, the LED
goes off (SLEEP mode).
Mains power present and battery
discharged (
gate locked).
The LED continues to flash rapidly until the
battery has recharged sufficiently.
If mains power is not supplied, the LED goes
off (SLEEP mode).
No mains power supplied (SLEEP mode).
Steady light
Slow flashing
(lights every
second)
Rapid flashing
(lights every 250
msec)
Light OFF
Tab. 2
- Description of LED P status
12.1
Powering up the system
After making all the cable connections we described previously,
power up the system to enable diagnostics, check of inputs
status and programming.
12.
START-UP
When the LEDs light up, this indicates the inputs status as shown
in Tab. 3.
12.3 Status of inputs
The MASTER-B board has a function for checking the status of
inputs on the terminal board.
In all LEDS OFF status (LEDs both with letters and numbers), press
the P2 push-button.
12.2 Diagnostics
LED "P" (see Fig.7) - visible from outside the enclosure - performs
the diagnostics function. The LED has 4 statuses:
Note:
in the SLEEP mode, an OPEN pulse is sufficient to move
the gate (with charged battery)
Fig. 7
t
12.4 Programming
These are the basic settings of the MASTER-B board:
MASTER-B board
LEAF 1
Function logic:
A4
Pause times:
B1
Opening/closing delay:
C3
Static force:
D3
Speed:
E2
If you wish to execute customised programming (see par. from
12.4.1 to 12.4.6) and time-learning (see par.12.4.7 and 12.4.8)
follow the steps in the next pages.
LEDs
Lighted
Off
(closed contact)
(open contact)
A = Open A
Command active
Command inactive
B = Open B
Command active
Command inactive
C = Stop
Command inactive
Command active
D = Fsw op
Safety devices disengaged
Safety devices engaged
E = Fsw cl
Safety devices disengaged
Safety devices engaged
1 = SLAVE-B
SLAVE-B present
SLAVE-B absent
and active
or inactive
Tab. 3
- Description of inputs status LEDs
P1
P2
Notes
:
•
The status of LEDs with the gate closed at rest is shown in
bold
.
•
LED 1 is active only when the MASTER-B and SLAVE-B boards
communicate in systems with double-leaf gates and with
the SLAVE-B battery charged.
•
In the inputs status function, push-button P1 commands an
OPEN A.
When checks have finished, once again press push-button P2
to exit the inputs status function.