950N
2
732773 - Rev. B
a
2
1
LOCK
J3
950 I/0
+
-
b
c
a
b
c
d
e
f
g
h
ENGLISH
FAULT
NUMBER
MEANING
LED STATUS:
a b c d e f g h
3
Attempt to force door open in progress
7
Emergency input active
8
Obstacle when opening detected three consecutive times. Reset requi-
red
9
Obstacle when closing detected three consecutive times. Reset required
10
Electric lock locked closed
12
No 24V= accessories power
13
failsafe test failed on closing
14
failsafe test failed on opening
15
Set-up prevented
18
Leaf stroke too long
20
Leaf stroke insufficient
22
Leaf too heavy
24
Motor failure
26
950 MPS board failure
28
Set-up cycle requested
29
Encoder failure
30
Motor drive on 950 MPS board failure
31
EEPROM failure
32
Master and slave communication error
KP controller and 950 I/0 board communication error
LED ON:
LED OFF:
Fig.2
Fig.3
3V CR1216
LITHIUM BATTERY
2x0.5 mm2
max 50m
Содержание KP CONTROLLER