manualshive.com logo in svg
background image

SEDE - HEADQUARTERS

FAAC S.p.A.

Via Calari, 10

40069 Zola Predosa (BO) - ITALY

Tel. +39 051 61724 - Fax +39 051 758518

www.faac.it - www.faacgroup.com

SUBSIDIARIES

AUSTRIA

FAAC GMBH

Salzburg - Austria

tel. +43 662 8533950

www.faac.at

FAAC TUBULAR MOTORS

tel. +49 30 56796645

[email protected]

www.faac.at

AUSTRALIA

FAAC AUSTRALIA PTY LTD

Homebush, Sydney - Australia

tel. +61 2 87565644

www.faac.com.au

BENELUX

FAAC BENELUX NV/SA

Brugge - Belgium

tel. +32 50 320202

www.faacbenelux.com

FAAC TUBULAR MOTORS

tel. +31 475 406014

[email protected]

www.faacbenelux.com

CHINA

FAAC SHANGHAI

Shanghai - China

tel. +86 21 68182970

www.faacgroup.cn

FRANCE

FAAC FRANCE

Saint Priest, Lyon - France

tel. +33 4 72218700

www.faac.fr

FAAC FRANCE - AGENCE PARIS

Massy, Paris - France

tel. +33 1 69191620

www.faac.fr

FAAC FRANCE - DEPARTEMENT 

VOLETS

Saint Denis de Pile - Bordeaux - France

tel. +33 5 57551890

www.faac.fr

ASSISTENZA IN ITALIA

SEDE

tel. +39 051 6172501

www.faac.it/ita/assistenza

FIRENZE

tel. +39 055 301194

[email protected]

GERMANY

FAAC GMBH

Freilassing - Germany

tel. +49 8654 49810

www.faac.de

FAAC TUBULAR MOTORS

tel. +49 30 5679 6645

[email protected]

www.faac.de

INDIA

FAAC INDIA PVT. LTD

Noida, Delhi - India

tel. +91 120 3934100/4199 

www.faacindia.com

IRELAND

NATIONAL AUTOMATION LIMITED

Boyle,Co. Roscommon - Ireland

tel. +353 071 9663893 

www.faac.ie

MIDDLE EAST

FAAC MIDDLE EAST FZE

Dubai Silicon Oasis free zone

tel. +971 4 372 4187

www.faac.ae

NORDIC REGIONS

FAAC NORDIC AB

Perstorp - Sweden

tel. +46 435 779500

www.faac.se

POLAND

FAAC POLSKA SP.ZO.O

Warszawa - Poland

tel. +48 22 8141422

www.faac.pl

RUSSIA

FAAC RUSSIA LLC

Moscow - Russia

tel. +7 495 646 24 29

www.faac.ru

MILANO

tel +39 02 66011163

[email protected]

PADOVA

tel +39 049 8700541

[email protected]

ROMA

tel +39 06 41206137

[email protected]

TORINO

tel +39 011 6813997

[email protected]

SPAIN

CLEM, S.A.U.

S. S. de los Reyes, Madrid - Spain

tel. +34 091 358 1110

www.faac.

SWITZERLAND

FAAC AG

Altdorf - Switzerland

tel. +41 41 8713440

www.faac.ch

TURKEY

FAAC OTOMATİK GEÇİS SİSTEMLERİ

SAN. VE TİC. LTD. ŞTİ.

Çağlayan, Kağıthane, İstanbul - Turkey

tel.+90 (0)212 – 3431311

www.faac.com.tr

UNITED KINGDOM

FAAC UK LTD.

Basingstoke, Hampshire - UK

tel. +44 1256 318100

www.faac.co.uk

U.S.A.

FAAC INTERNATIONAL INC

Rockledge, Florida - U.S.A.

tel. +1 904 4488952

www.faacusa.com

FAAC INTERNATIONAL INC

Fullerton, California - U.S.A.

tel. +1 714 446 9800

www.faacusa.com

732773- Rev. B

Содержание KP CONTROLLER

Страница 1: ...KP CONTROLLER q q OK ...

Страница 2: ...LLER must be connected to the 950 I O board using a 2 x 0 5 mm2 max 50 m cable Fig 2 If the two LOCK terminals are connected to each other as shown in Fig 2 all programmer keys are inhibited 4 DIAGNOSTICS The KP CONTROLLER even without display features a diagnostic function which in case of fault interrupts every 2 sec normal visualisation of the operating mode and si gnals for 1 sec the fault con...

Страница 3: ...d 10 Electric lock locked closed 12 No 24V accessories power 13 failsafe test failed on closing 14 failsafe test failed on opening 15 Set up prevented 18 Leaf stroke too long 20 Leaf stroke insufficient 22 Leaf too heavy 24 Motor failure 26 950 MPS board failure 28 Set up cycle requested 29 Encoder failure 30 Motor drive on 950 MPS board failure 31 EEPROM failure 32 Master and slave communication ...

Страница 4: ...th the motor powered e NIGHT The door closes The internal and external radars are disabled The key control Key causes opening and closing after the night pause time standard 7 sec For partial opening in this mode before selecting Night mode activate Partial opening mode 6 SPECIAL FUNCTIONS 6 1 SET UP Set up is the door initialisation function during which parameter self learning is performed It is...

Страница 5: ...setting parameters Use thep or q keys to select the submenu or parameter and OK to confirm An asterisk on the display indicates the currently active setting To exit programming select exit at each level as an alternative after approximately 2 minutes the display will automatically return to standard visualisation Following are the flow charts and notes describing the various menus and programming ...

Страница 6: ...ING SETUP 80 PAUSE TIME 7 SEC EXIT 2 SEC OBSTACLE DETECTION CLOSING STANDARD CLOSING NO STANDARD ITALIANO ENGLISH DEUTSCH FRANCAIS ESPANOL LANGUAGE Diagram 2 Language selection The language choice can vary depending on the programming country Diagram 3 Setup ...

Страница 7: ...950N 6 732773 Rev B ENGLISH Diagram 4 Lock OFF ALWAYS ONE WAY NIGHT NIGHT ON LOCK KIT LOCK EXIT Diagram 5 Diagnostics RESET DIAGNOSTICS 950 v NR of CYCLES XXXX FAULT nr fault description ...

Страница 8: ... 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 MOTION PARAMETERS CLOSING SPEED OPENING SPEED MAINTAIN SETTINGS OFF ON 8 8 EXIT IN OUT SETUP OTHER EXIT CHANGE PASSWORD incorrect code correct code Diagram 6 Motion parameters ...

Страница 9: ...am 7 In Out Setup PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code MOTION PARAMETERS IN OUT SETUP OTHER EXIT CHANGE PASSWORD EMERG OPENS CLOSES OUT OP CL NO FAULT OUT NO NC EXIT NC NO NC ...

Страница 10: ...ORD 0000 MOTION PARAMETERS IN OUT SETUP OTHER EXIT CHANGE PASSWORD STAND SETUP STANDARD NO STANDARD INTERLOCK MASTER SLAVE NO MEMORY WITH MEMORY EXIT NEW PASSWORD 0000 restore standard configuration MASTER SLAVE ON OFF ON OFF 2 LEAVES PROG TEST ON OFF NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 incorrect code correct code ...

Страница 11: ... 00 SUN 00 00 00 00 00 CLOCK SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 Diagram 9 Clock Diagram 10 Timer TIMER ON OFF ...

Страница 12: ...D 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 ...

Страница 13: ...d if the cause of the previously signalled fault has been eliminated it restores normal operation 5 ADVANCED MENU PASSWORD To access the advanced menu the 4 digit password is required default 0000 1 MOTION PARAMETERS Diagram 6 1 1 CLOSING SPEED Sets the door speed during closing Standard value level 8 Adjustment from 0 to 10 1 2 OPENING SPEED Sets the door speed during opening Standard value level...

Страница 14: ...o NIGHT mode 8 PROGRAMMING TIMER Diagram 11 Makes it possible to create up to 5 different time bands for each day of the week setting the band start time and give each time band an operative function When the KP CONTROLLER internal clock reaches the start of a time band the associated operative function is automatically set and the door stays in that condition until the following time band is trig...

Страница 15: ... of door 2 If interlock with memory is selected it is not necessary to wait for the door to be closed completely to activate the sensor on the second one 6 Door 2 opens 7 The person exits 8 Door 2 closes after the night pause time Operation is similar when coming from the opposite direction 8 1 2 INTERLOCK WITHOUT INTERNAL SENSORS buttons This application is recommended when the reduced distance b...

Страница 16: ... automated systems causes immediate reversal of both The partial opening function makes it possible to control total opening only of the master The operating functions must be set only on the master automated system or on the KP Controller connected to it 1 Connect the 950I O board of the two automated systems as shown in fig 8 2 Connect all the sensors and pulse transmitters only to the master 3 ...

Страница 17: ......

Страница 18: ...6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 353 071 9663893 www faac ie MIDDLE EAST FAAC MIDDLE EAST FZE Dubai Silicon Oasis free zone tel 971 4 372 4187 www faac ae NORDIC REGIONS FAAC NORDIC AB Perstorp Sweden tel 46 435 779500 www faac se POLAND ...

Отзывы: