27
code
#
Code = Pin code 4-6 digit code.
9999
#
84
code
#
Delete code
–
Code=known code to be deleted.
N/A
9999
#
84
*
#
Delete all codes.
N/A
Notifications
9999
#
80
X
#
X=1 to disable. X=2 to enable.
N/A
9999
#
78
XXX
#
X=phone number to send notifications to. (*=delete
number)
N/A
9999
#
79
text
#
X=text to send to the receiving phone e.g. “gate opened”
N/A
Automatic Time Clock Trigger Times
1234
#
X
#
day,day,day
#
time
#
X=1,2.3 (trigger, latch, unlatch relay 1) 4,5,6 (relay 2)
Day = days of the week (mon,tue,wed,thur,fri,sat,sun)
Time = time of day (24 hr format, no colon. E.g. 8:30am =
0830)
N/A
1234
*
X
#
Delete ALL automatic trigger times.
N/A
Clock Sync - Auto Time Calibration after Power Fail
9999
#
86
XXX
#
X=telephone number of SIM inside the intercom.
N/A
9999
#
86
*
#
Delete the phone number.
N/A
Summer Daylight Auto Correct
9999
#
87
??
#
?? = number of days between SMS calibration SMS should
be sent. 0 = no message sending.
N/A
Do Not Disturb (push button de-activated during set times)
1234
#
21
#
ON
# ON = activated. OFF = de-activated.
OFF
9999
#
21
#
day,day,day
#
time1,time2
#
Enter all active days during which button should operate.
Enter start and end time button should operate
(24 hr format, no colon. E.G 8:30am = 0830)
N/A
Alternate Number to Call During Do Not Disturb Times.
9999
#
21X
????
#
X = button number (1-9. Enter 1 for 1 button system. Enter 0
for button 10)
???? = Alternative phone number to call out of hours.
Restore Defaults
9999
#
999
#
Send with passcode string to clear all programming.
N/A
Control by SMS
This intercom allows the user to send SMS commands to control the relays and check status as
follows…
1234#
1
# - Relay 1 momentary trigger.
1234#
2
# - Relay 1 latch ON or hold ON.
1234#
3
# - Relay 1 unlatch or switch OFF.
1234#
4
# - Relay 2 momentary trigger.
1234#
5
# - Relay 2 latch ON or hold ON.
1234#
6
# - Relay 2 unlatch or switch OFF.