manualshive.com logo in svg
background image

 

 

 

Cellular Intercom 3G 

FAAC International Inc. 
Headquarter & East Coast Operations 
3160 Murrell Rd 
Rockledge, FL 32955 
Tel. 800 221 8278 
www.faacusa.com 

FAAC International Inc. 

West Coast Operations 

357 South Acacia Avenue 

Fullerton, CA 92831 

 

 

  

 

 

DO NOT GIVE TO HOME OWNER

.  

     FOR PROFESSIONAL USE ONLY       

 

3

G  

 
 

Содержание FCI4300

Страница 1: ...Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fullerton CA 92831 DO NOT GIV...

Страница 2: ...up and LEDS Installing the programmer APP for the first time Programming a brand new install Programming an existing install Programming main steps Additional Features Keypad codes Prox cards optional...

Страница 3: ...e gate door of the install site BEFORE installing this product Set up on a bench in workshop BEFORE going to site Program the unit in the comfort of your work bench and call technical support should y...

Страница 4: ...ll button Push button Speaker grill Cellular PCB Optional Prox Coil Optional Keypad module Optional Keypad Optional Prox reader module Surge Power Conditionin g Module Hinged front door Microphone Bui...

Страница 5: ...seneck re fit the module and connect a 14 gauge earth wire to the earth terminal 2 Earth Rod close as possible Maintain manufacturer s warranty by adhering to the guidelines shown Use 110v surge prote...

Страница 6: ...3Ah 12v dc max Power Module in Detail Earth Rod Connection Gate Position Limit switch optional 1A quick blow input fuse Exit Button To Call Button pre wired 12v dc 100mA button illumination 24v dc IN...

Страница 7: ...PROX Modules in Detail Slave OUT connections Wiring Relays Electric Gates 24v out GND Note The manufacturer is not responsible for wiring to third party devices Please consult an experienced security...

Страница 8: ...e while power on To next device Optional Keypad Optional Prox reader Optional Slave Keypad Optional Slave Prox Reader CAT5 30ft max 300ft if device powered separately To next device 45 chamfer OUT Pad...

Страница 9: ...for the first time If you are using an Apple or Android smart phone download and install the FAAC Cell Access Pro APP It will make programming much easier Note You may notice the app Cell Access on t...

Страница 10: ...10 Accept and allow all permissions Android version shown After you send the registration email go back to the app screen To register first time enter your name email and cell phone number...

Страница 11: ...mming an EXISTING Install Enter site or customer name and INTERCOM PHONE NUMBER If Engineers and user pass codes are at default then do not change these Once completed you are ready to begin programmi...

Страница 12: ...On iphone users will be taken to their SMS screen to confirm before sending the string The intercom should reply with a signal level between 1 31 1 12 Poor 13 20 Medium 21 31 Good For good performanc...

Страница 13: ...n the intercom Step 3 Activate Daily Activity This feature is needed for 2 reasons 1 To prevent some cellular carriers disconnecting the 4G LTE due to inactivity on the device 2 To keep time synchroni...

Страница 14: ...73telephonenumber To delete all numbers 9999 73 Step4 Programming Numbers for the intercom to call 1 Press the SINGLE home icon for a 1 button system or MULTI for a 10 button system 2 Simply enter ce...

Страница 15: ...on E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the days which access are to be granted SMS string for time restricted caller ID 9999 72 day day da...

Страница 16: ...tricted Code Stores up to 20 codes which can be restricted to pre set times and days of the week Relay 1 only Enter a 4 digit code Enter start time in 24hr format military style with no colon E g 8 30...

Страница 17: ...k during pre set times and days of the week Temporary Prox cards which auto expire in a pre se time Check stored Prox cards Intercom will reply with SMS message Temporary Code Stores up to 30 codes wh...

Страница 18: ...ys and times of the week Relay 1 only Enter start time in 24hr format military style with no colon E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the...

Страница 19: ...D to be deleted Deleting ALL cards 9999 64 Enter known card ID 10 digits xxxxxxxx Delete all stored cards and start again Auto Expiring Temp Cards Store up to 30 cards which auto expire within a certa...

Страница 20: ...losing gates use latching and unlatching commands to control open times 1234 1 day day day time USER passcode Command 1 trigger relay 1 2 latch relay 1 3 unlatch relay 1 4 trigger relay 2 5 latch rela...

Страница 21: ...button press outside of these times will be ignored by the intercom Quick enable disable button Set start and end time for button active times 24hr format no colon E g 8 30am 0830 Set the days in whi...

Страница 22: ...osition 1 4 Programming codes There are 2 main SMS programming pass codes on the intercom One for the installer default 9999 and the other for the user homeowner default 1234 It is advised to change t...

Страница 23: ...mber 9999 46XX X dialling time for second number 9999 47XX X dialling time for third number 9999 53XX X talking time in seconds 9999 max Volumes Adjust microphone and speaker volumes 1 9 default 5 If...

Страница 24: ...nt 22 Open Relay1 on Relay2 off open refers to state of the status input connection in the intercom Relay 1 and 2 will show ON if latched 1234 26 NORM xxxx PLAN xxxxx TEMP xxxxx 1234 25 NORM xxxx PLAN...

Страница 25: ...out numbers 9999 1XY Store dialling out numbers X button number 1 9 0 for button 10 Y number dialled 1 4 phone number N A 9999 1XY Delete a dial out number X button number Y number position 1 4 N A Vo...

Страница 26: ...99 58 Choose between making a scheduled call or scheduled SMS 1 SMS 2 call 1 9999 77 Delete the stored service number N A Caller ID features 9999 72number Store caller ID number Max 14 digits Only las...

Страница 27: ...ct 9999 87 number of days between SMS calibration SMS should be sent 0 no message sending N A Do Not Disturb push button de activated during set times 1234 21 ON ON activated OFF de activated OFF 9999...

Страница 28: ...time as per programming instructions Q The caller ID part does not work A Be sure to program the caller ID part under 72 feature If your number is a private or number withheld then it will not work E...

Страница 29: ...power supply directly to the unit Q The system was operating the gates fine but now it will not trigger the gates Frequently this is cause by the user accidentally latching the relay This latches the...

Страница 30: ...product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions m...

Страница 31: ...erference and 2 this device must accept any interference received including interference that may cause undesired operation Output power listed is ERP below 1GHz for Part 22 and EIRP above 1GHz for Pa...

Страница 32: ...32 Note For legal reasons telephone technical support is for registered and qualified product dealers only Home owners and end users should contact their local dealer for product technical support...

Отзывы: