background image

Operation Manual

 

IO Link Master - PROFINET

NC-MP-4A4B-12DLA/AL1403

Before starting work read these instructions.

This manual contains proprietary information. No part of this 

publication may be reproduced, transcribed or transmitted 

in any form without the written consent of the publisher. 

Every effort has been made to ensure that the information 

contained in this manual is accurate. All rights reserved.

Summary of Contents for NC-MP-4A4B-12DLA/AL1403

Page 1: ...structions This manual contains proprietary information No part of this publication may be reproduced transcribed or transmitted in any form without the written consent of the publisher Every effort has been made to ensure that the information contained in this manual is accurate All rights reserved ...

Page 2: ... 4 Function 8 4 1 Parameter setting 8 4 2 Visual indication 8 4 3 PROFINET 8 4 4 IO Link 9 4 4 1 IO Link supply 9 4 4 2 Digital inputs 9 4 4 3 Digital outputs 9 4 5 Voltage output 9 5 Mounting 10 5 1 Installing the device 10 6 Electrical connection 11 6 1 Notes 11 6 2 Connect PROFINET ports 12 6 3 IO Link Ports verbinden 13 6 4 Ground the device 14 6 5 Connect the device 15 7 Operating and display...

Page 3: ...oot the device 30 9 1 15 Configure IO Link devices 31 9 2 PROFINET 32 9 2 1 Install GSD Files 32 9 2 2 Integrate the IO Link master in the project 33 9 2 3 Configure the IO Link master 34 9 2 4 Configure IO Link ports 37 9 2 5 Configure IO Link devices 39 9 2 6 Read and write process data 39 9 2 7 Read I M datasets 40 9 2 8 Detect diagnostics and alarms 40 10 Operation 41 10 1 Use web based manage...

Page 4: ...et is the property of the ODVA Open DeviceNet Vendor Association USA www odva org EtherNet IP is the property of the ODVA EtherCAT is a registered trade mark and patented technology licensed by Beckhoff Automation GmbH Germany IO Link is the property of the PROFIBUS User Organization Germany www io link com ISOBUS is the property of the AEF Agricultural Industry Electronics Foundation e V Deutschl...

Page 5: ... 1 4 Modification history Important note Non compliance can result in malfunction or interference Information Supplementary note Request for action Reaction result see abc Cross reference 123 Decimal number 0x123 Hexadecimal number 0b010 Binary number Designation of pushbuttons buttons or indications WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTI...

Page 6: ...ls on the device 6 Tampering with the unit 6 2 1 General The plant manufacturer is responsible for the safety of the plant in which the device is installed If the device is used in a way that is not intended by the manufacturer the protection supported by the device may be impaired Non observance of the instructions operation which is not in accordance with use as prescribed below wrong installati...

Page 7: ...onic files are provided by ifm The IO Link master serves as a gateway between intelligent IO Link devices and the PROFINET network The device is designed for use without a control cabinet in the plant construction The device may not be used beyond the limits of the technical data Technical data S 53 3 1 Permitted use 3 2 Prohibited use 3 Intended use Content Permitted use 7 Prohibited use 7 ...

Page 8: ...owing visual indicators Status and error indication of the gateway of the PROFINET connection and of the system Status display of the voltage supply Status and activity display of the Ethernet connection Status error and short circuit overload indication of the IO Link ports The device offers the following ProfiNet functions PROFINET RT Device Conformance Class C 2 port switch for access to the PR...

Page 9: ...he current intensity of the supply voltage US of the ports X5 X8 can be set Every supply provides short circuit monitoring The device ensures fire protection for connected IO Link devices by providing an energy limited circuit at the ports according to IEC61010 1 and Class 2 to UL1310 The device has 4 additional digital inputs type 2 according to EN 61131 2 The digital inputs are on pin 2 of the p...

Page 10: ...s AL1403 All firmware and electronic files are provided by ifm 5 Mounting Content Installing the device 10 5 1 Installing the device Disconnect power before installation Please observe the maximum tightening torque Use a plane mounting surface for installation Fix the unit to the mounting surface using 2 M5 mounting screws and washers Tightening torque 1 8 Nm ...

Page 11: ...protective caps Provide cables with a strain relief depending on the mounting conditions to avoid ex cessive strain on the installation points and the M12 connections Ensure correct fit and proper assembly of the M12 connecting parts If these instruc tions are not complied with the specified protection rating cannot be guaranteed For UL applications To connect the IO Link master and the IO Link de...

Page 12: ...To connect the devices use M12 connectors with protection rating IP 65 IP 66 IP 67 or higher Accessories S 51 Cover the unused sockets with M12 protective caps art no E73004 Tightening torque 0 6 0 8 Nm 13 NC MP 4A4B 12DLA 6 2 Connect PROFINET ports Connect the device via the M12 socket XF1 and or XF2 with the PROFINET network e g PROFINET PLC additional PROFINET device Tightening torque 0 6 0 8 N...

Page 13: ...le connectors Risk of fire Impairment of electrical safety Malfunctions To connect IO Link Class A devices to Class B ports use 3 pole connectors only Detailed information IO Link planning directive www io link com 14 CAUTION Connection of IO Link Class A devices Class with Class B ports with 4 5 pole connectors Risk of fire Impairment of electrical safety Malfunctions To connect IO Link Class A d...

Page 14: ... the protection of the device against electrical interference and to ensure the safe function of the device the housing must be connected to the GND of the installation using the shortest possible route 15 NC MP 4A4B 12DLA 6 4 Ground the device The FE potential is connected to the following points of the device Upper mounting lug of the housing Ports XD1 and XD2 Pin 5 FE Ports XF1 and XF2 To ensur...

Page 15: ...N Exceeding the maximum input current of 12 A Fire hazard Select IU and IA of the power supplies US and UA taking into account the derating characteristics of the NC MP 4A4B 12DLA AL1403 Derating behavior S 54 16 NC MP 4A4B 12DLA 6 5 Connect the device Disconnect power Connect the device via M12 socket X31 to US and UA supplying 24 V DC each 20 30 V SELV PELV according to IEC 61010 1 secondary cir...

Page 16: ...ltage supply XD1 XD2 Voltage supply S 19 4 Status LEDs IOL and UA DO of the IO Link Class B ports X1 X4 IO Link Ports Class B S 19 5 Status LEDs IOL and DI of the IO Link Port Class A X5 X8 IO Link Ports Class A S 20 7 Operating and display elements Content Overview 16 LED indicators 17 Status LEDs RDY BF and SF Status LEDs S 18 Status LEDs LNK and ACT of the PROFINET interfaces 1 XF1 and 2 XF2 Et...

Page 17: ...the status of the Ethernet connection 7 2 LED indicators 7 2 1 Status LEDs 7 2 2 Ethernet ports Status LED Description RDY green on Status OK flashes 5 Hz Status Error flashes 200 ms on 800 ms off Status Firmware update is running off Status Gateway not running or gateway booting BF red on Bus error flashes 1 Hz No connection to the PROFINET controller off error free SF red on Error in gateway At ...

Page 18: ...pin 4 C Q ON green flashing 1 Hz Port configured asIO Link no IO Link device found Flashing with 2 Hz Port configured asIO Link Status PREOPERATE on Port configured asIO Link Status OPERATE red Flashing with 2 Hz Port configuration error or short circuit overload on US on Transmission error UA DO yellow Off Digital output Pin 2 UA OFF on Digital output Pin 2 UA ON green Off IO Link type A supply P...

Page 19: ... files are provided by ifm 8 1 Parameter setting options The device can be configured with the following options Software LR DEVICE LR DEVICE S 23 PROFINET projecting software PROFINET S 35 When the supply voltages have been switched on the NC MP 4A4B 12DLA AL1403 starts with the factory settings The LEDs signal the current operating status of the device and the ports LED indicators S 18 8 Setup ...

Page 20: ...24 Fieldbus Configure IP settings 24 IO Link ports Activate data transfer to LR AGENT or LR SMARTOBSERVER 25 IO Link ports Set the operating mode Pin 2 UA 25 IO Link Ports restrict current intensity 26 IO Link ports Set the operating mode Pin 4 27 IO Link ports Set the device validation and data storage 28 IO Link Ports Set fails safe values 29 Info Show device information 29 Firmware Reset device...

Page 21: ... 21 VPN connection The parameters of the IO Link master and the connected sensors and actuators can be set before installation and set up or during operation Online parameter setting Further information about offline parameter setting Operating instructions LR DEVICE An active VPN connection blocks the access of the parameter setting software LR DEVICE to the PROFINET interface of the NC MP 4A4B 1...

Page 22: ...er documentation LR DEVICE Establish Ethernet connection between PC and Port XF1 or XF2 2 Start LR DEVICE and update the device library Start LR DEVICE Update the device library The device library contains the IO Link device description file of the IO Link master 3 Look for IO Link master Im LR DEVICE Scan the network for devices LR DEVICE searches the network for IO Link masters and IO Link devic...

Page 23: ...devices PROFINET IoT PROFINET and IoT Core have read and write access rights to parameters and process data PROFINET and IoT Core have read access rights to events alarms PROFINET IoT read only PROFINET has read and write access rights to parameters and process data PROFINET has read access rights to events alarms IoT Core only has read access rights to parameters process data and events alarms Io...

Page 24: ...SERVER Factory setting 255 255 255 255 Port LR Agent or SMARTOBSERVER Port number that is used to send process data to LR AGENT or LR SMARTOBSERVER 0 65535 Factory setting 35100 Interval LR Agent or SMARTOBSERVER Cycle time for the transfer of the process data to LR AGENT or LR SMARTOBSERVER value in milliseconds Off no transfer 500 2147483647 500 ms 2147483647 ms Application Tag Source identifier...

Page 25: ... Output Digital switching output To transfer process data the interface to the LR AGENT or LR SMARTOBSERVER has to be correctly configured IoT Configure the interface to LR AGENT or LR SMARTOBSERVER S 27 Save changed values on the device Save changed values on the device The user can decide separately for each IO Link port whether the process data of the connected IO Link devices should be transfe...

Page 26: ...sity For the IO Link ports X1 X4 the following features can be set Max current intensity of the supply voltage US Max current intensity of the supply voltage UA For the IO Link ports X5 X8 the following features can be set Max current intensity of the supply voltage US Name Description Possible values Current Limit Pin2 UA Max current intensity of the supply voltage UA on the port value in milliam...

Page 27: ...C Q of the IO Link port IO Link IO Link data transfer via pin 4 C Q of the IO Link port Save changed values on the device Parameter only available if Mode IO Link Parameter only visible if the IO Link device is connected to the IO Link port Name Description Possible values Mode Pin4 US Operating mode of the pin 4 of the port Disabled no data transmission DI digital input DO digital output IO Link ...

Page 28: ...ce with factory settings 9 1 10 IO Link ports Set the device validation and data storage The options only apply if the IO Link port is in the operating mode IO Link For options Type compatible V1 1 device with Backup Restore and Type compatible V1 1 device with Restore If the vendor ID and device ID are changed in the online mode the data memory will be deleted and a new backup of the parameter va...

Page 29: ...IO Link master Select Info menu The menu page shows the current settings Name Description Possible values Fail safe digital out Fail safe value of the output for operating mode Digital Output DO Reset OFF Old old value Set ON Fail safe IO Link Fail safe value of the output for operating mode IO Link Off no Fail safe Reset Fail safe OFF Old Fail safe old value Pattern Fail safe byte pattern Save ch...

Page 30: ...hen the IO Link master is reset all parameters are set to the factory settings To reset the device to factory settings Select Firmware menu The menu page shows the current settings Click on Factory Reset to reset the device LR DEVICE sets the device to the factory settings When rebooting the device all settings are kept To restart the NC MP 4A4B 12DLA AL1403 Select Firmware menu The menu page show...

Page 31: ...access rights to the IO Link master IoT Configure access rights S 26 1 Select IO Link master Start LR DEVICE Update IODD file library OR Import IODD file of the IO Link device manually Scan network for devices LR DEVICE detects IO Link master 2 Add IO Link device Under ONLINE Click on the required IO Link master LR DEVICE automatically detects the IO Link devices connected to the IO Link master e ...

Page 32: ...OFINET parameter setting software Use the help function of the PROFINET projection software On the field bus side the device can be configured with the following options PROFINET projection software STEP 7 version 5 5 SP 4 or higher PROFINET projection software TIA portal IMI Norgren provides a GSD file to map the IO Link masters of the AL14 device family in the PROFINET projecting software The us...

Page 33: ...the project The IO Link master is loaded with a default configuration into the project The IO Link master is part of the project To integrate the IO Link master in the infrastructure the IP settings of the fieldbus interface must be configured correspondingly In the Devices networks view Double click on the IO Link master The overview Device overview of the IO Link master Select the slot 0 X1 PN I...

Page 34: ...ll appear as AL1403 All firmware and electronic files are provided by ifm 9 2 3 Configure the IO Link master Content IO Link Master Set operating mode 35 IO Link Master Set the module parameters 36 Access to the configuration of the IO Link master via the following slots Slot Description 1 Profile of the IO Link master 1 IOLM proxy IOLM Proyx module ...

Page 35: ... Master Proxy 8P Standard IO Link Master IOLM Proxy 1 byte of cyclic input data digital inputs 1 byte of cyclic output data digital outputs IOLD proxy per port max 33 bytes of cyclical process data digital inputs IO Link inputs PQI max 32 bytes of cyclical process data IO Link outputs Mix Mode Energy Monitoring 8 ports IO Link Master Proxy 8P EnMo Standard IO Link master with active energy monitor...

Page 36: ...de S 38 The device catalogue is open in the project Double click on NC MP 4A4B 12DLA AL1403 The window Device overview shows the slot configuration of the NC MP 4A4B 12DLA AL1403 Select slot 1 IOLM proxy The window Properties General shows properties of the IO Link master Select the Module parameters menu The window shows available parameters of the IOLM proxy module Change the parameter values Sa...

Page 37: ...ion of the operating mode and process data Slot Description 1 X1 B Port Configuration of port X1 1 X2 B Port Configuration of port X2 1 X3 B Port Configuration of port X3 1 X4 B Port Configuration of port X4 1 X5 A Port Configuration of port X5 1 X6 A Port Configuration of port X6 1 X7 A Port Configuration of port X7 1 X8 A Port Configuration of port X8 Access to the configuration of the IO Link p...

Page 38: ...e Pull Plug X X X Port Mode X X X Validation Data Storage X X X Vendor ID VID X X X Device ID DID X X X Port Cycle Time X X X The different IOLD proxy modules have specific parameter sets IO Link Ports Parameter setting X Parameter available Details about the parameters of the IOLD proxy modules Parameters of the IOLD proxy modules S 65 To set the parameters of an IOLD proxy module The operating m...

Page 39: ...ALL FB1 Acyclic access to the parameters of an IO Link device obsolete IO_LINK_DEVICE FB5001 Depending on the selected IO Link master profile the digital process data of the ports operating modes digital input digital output will be mapped to different address ranges Mix Mode each digital process value pin 4 receives a separate address IO Mode Digital process data of the ports pin 4 are transferre...

Page 40: ...on software by means of the following functions 9 2 7 Read I M datasets 9 2 8 Detect diagnostics and alarms Symbol function block Description Notes GET_IM_DATA Function block for reading the I M datasets of a device GET_IM_DATA only supports the reading of the I M0 dataset Input parameters IM_TYPE 0 RDREC Function block for acyclic reading of datasets Input parameters I M0 Index 0xAFF0 I M1 Index ...

Page 41: ...enerates a website with the following data Status information of the ports Diagnostic information of the device Version information of the installed firmware components To access the web interface of the IO Link master Connect the IO Link master via port XF1 or XF2 with the laptop PC Optional Check the IP settings of the PROFINET interface Start web browser In the address field of the web browser ...

Page 42: ... ifm 11 Maintenance repair and disposal 11 1 Cleaning process Content Cleaning process 42 Update the firmware 43 Exchanging the IO Link device 44 The operation of the unit is maintenance free Dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations when it is no longer used Clean the surface of the unit when necessary Do not use any caustic clea...

Page 43: ...appears Select the firmware file bin and click on Open in order to adopt the file Click on Submit to start the firmware update Firmware is being loaded to the device After successful storage the success message is displayed 3 Reboot the IO Link master Click on Restart device now to restart the device The RDY status LED flashes rapidly Firmware is updating Follow the instructions in the browser The...

Page 44: ...the old IO Link device Create the following parameter of the IO Link port Device validation and data storage Type compatible V1 1 device with Restore Save the changes on the device The IO Link master saves the parameter values of the connected IO Link device in the data memory 2 Exchange IO Link device Disconnect the old IO Link device from the IO Link master Connect the new IO Link device with th...

Page 45: ...nic interfaces this device will appear as AL1403 All firmware and electronic files are provided by ifm 12 Factory Settings Parameter Factory setting IP address 0 0 0 0 Subnet mask 0 0 0 0 IP gateway address 0 0 0 0 Host name blank Data Storage empty In the factory settings the device has the following parameter settings ...

Page 46: ... 12DLA AL1403 This device is powered by ifm In all electronic interfaces this device will appear as AL1403 All firmware and electronic files are provided by ifm 13 Accessories List of accessories of NC MP 4A4B 12DLA AL1403 www Norgren com Product page Accessories ...

Page 47: ...e provided by ifm 14 Appendix 14 1 Technical data Content Technical data 47 PROFINET 47 Content Application 47 Electrical data 48 Inputs outputs 50 Inputs 50 Outputs 50 Interfaces 51 Environmental conditions 51 Approvals tests 51 Mechanical data 51 Electrical connection 52 14 1 1 Application Application Application I O modules for field applications Daisy chain function Voltage supply Fieldbus int...

Page 48: ...ply V 20 30 DC UA Sensor supply US Total current rating A 3 6 Current rating per port A 2 configurable 0 2 factory setting 0 45 Actuator supply UA Total current rating A 8 Current rating per port A 2 configurable 0 2 factory setting 2 Derating behavior UA to ports X1 X4 Temperature C Amperage I A Port XD1 US to ports X1 X8 Derating without daisy chain 1 2 NC MP 4A4B 12DLA 14 12 10 8 8 8 8 8 8 8 7 ...

Page 49: ... 50 60 30 20 10 0 10 20 30 40 50 60 Temperature C Temperature C 1 XD1 UA to port X1 X4 2 XD1 US to port X1 X8 3 XD2 UAdaisychain 4 XD2 USdaisychain Example Temperature IUA IUS IUAdaiyschain IUSdaisychain 30 C 8 A 3 6 A 8 A 12 A Amperage I A Port XD1 Amperage I A Port XD2 55 NC MP 4A4B 12DLA Derating with daisy chain 30 20 10 0 10 20 30 40 50 60 30 20 10 0 10 20 30 40 50 60 Temperature C Temperatur...

Page 50: ...uts 24 configurable Number of inputs and outputs Number of digital inputs 12 Number of outputs 12 Inputs Number of digital inputs 12 IO Link Port Class A 4 x 2 IO Link Port Class B 4 x 1 Switching level high V 11 30 Switching level low V 0 5 Digital inputs protected against short circuits yes Outputs Number of digital outputs 12 IO Link Port Class A 4 x 1 IO Link Port Class B 4 x 2 Short circuit p...

Page 51: ...Materials Housing PA socket brass nickel plated Approvals tests EMC EN 61000 6 2 EN 61000 6 4 Shock resistance DIN EN 60068 2 27 Vibration resistance DIN EN 60068 2 64 2009 04 DIN EN 60068 2 6 2008 10 Interfaces Communication interface Ethernet IO Link Ethernet Max current load per output mA 2000 Transmission standard 10Base T 100Base TX Transmission rate MBit s 10 100 Protocol PROFINET IO Factory...

Page 52: ...M12 Wiring 1 Sensor supply US L 2 Actuator supply UA L DO 3 Sensor supply US L 4 C Q IO Link 5 Actuator supply UA L Process connection of Ports Class A X5 X8 Connector M12 Wiring 1 Sensor supply US L 2 DI 3 Sensor supply US L 4 C Q IO Link 5 59 14 1 10 Electrical connection Voltage supply IN XD1 Connector M12 L coded Wiring 1 24 V DC US 2 GND UA 3 GND US 4 24 V DC UA 5 FE Voltage supply OUT XD2 Co...

Page 53: ...ntent Device structure 53 Parameter data 54 Cyclic data 60 Acyclic data 66 Slot Subslot Label Description 0 0x8000 X1 Parameter PROFINET IO 0x8001 X1 P1 Parameter Port XF1 0x8002 X1 P2 Parameter Port XF2 1 0x1 IOLM proxy IOLM proxy module S 61 Parameters of the IOLM proxy modules S 62 0x2 X1 B Port IOLD proxy modules S 63 Parameters of the IOLD proxy modules S 65 0x3 X2 B Port 0x4 X3 B Port 0x5 X4...

Page 54: ...y ifm 14 2 2 Parameter data IOLM proxy module Content IOLM proxy module 54 Parameters of the IOLM proxy modules 55 IOLD proxy modules 56 Parameters of the IOLD proxy modules 58 Module IO Link Master Proxy Description 8 Ports IO Link Master Proxy 8P Standard IO Link Master 8 Ports IO Link Master Proxy 8P EnMo IO Link master with energy monitoring 8 Ports IO Mode IO Link Master Proxy 8P IO Mode IO L...

Page 55: ...process data and events alarms PROFINET only PROFINET has read and write access rights to parameters and process data PROFINET has read access rights to events alarms LR DEVICE has no access rights parameters process data events alarms web interface firmware update keep setting previous setting is valid Mode Pin2 Actuator Supply UA Operating mode of the supply voltage UA on pin 2 of the IO Link po...

Page 56: ...nk 16 I 1 O Byte PQI IO Link 16 bytes input data and 1 byte output data and PQI IO Link 16 I 16 O Byte PQI IO Link 16 bytes input data and 16 bytes output data and PQI IO Link 32 I 1 O Byte PQI IO Link 32 bytes input data and 1 byte output data and PQI IO Link 32 I 32 O Byte PQI IO Link 32 bytes input data and 32 bytes output data and PQI IO Link 1 I Byte PQI IO Link 1 bytes input data and PQI IO ...

Page 57: ...6 bytes input data and 1 byte output data and PQI IO Link 16 I 16 O Byte PQI IO Link 16 bytes input data and 16 bytes output data and PQI IO Link 32 I 1 O Byte PQI IO Link 32 bytes input data and 1 byte output data and PQI IO Link 32 I 32 O Byte PQI IO Link 32 bytes input data and 32 bytes output data and PQI IO Link 1 I Byte PQI IO Link 1 bytes input data and PQI IO Link 2 I Byte PQI IO Link 2 by...

Page 58: ... output Validation Data Storage Supported IO Link standard and behavior of the NC MP 4A4B 12DLA AL1403 when connecting new IO Link devices to the IO Link port no Device check and clear no verification of the vendor ID and device ID no data storage type compatible Device V1 0 IO Link device is compatible with the V1 0 IO Link standard Verification whether it is an IO Link device of the same type va...

Page 59: ... on the IO Link port As fast as possible The device automatically sets the fastest possible cycle time 2 0 ms 2 milliseconds 4 0 ms 4 milliseconds 8 0 ms 8 milliseconds 16 0 ms 16 milliseconds 32 0 ms 32 milliseconds 64 0 ms 64 milliseconds 128 0 ms 128 milliseconds Vendor ID ID of the manufacturer that is to be validated 0 65535 ID of the manufacturer of the IO Link device Norgren 310 Device ID I...

Page 60: ... Digital Input Pin 4 Port X3 Digital Input Pin 4 Port X2 Digital Input Pin 4 Port X1 Digital Input Pin 4 Byte offset Contents Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 n res res res res Port X4 Digital Output Pin 2 Port X3 Digital Output Pin 2 Port X2 Digital Output Pin 2 Port X1 Digital Output Pin 2 n 1 Port X8 Digital Output Pin 4 Port X7 Digital Output Pin 4 Port X6 Digital Output Pin 4 P...

Page 61: ...t X8 Status Actuator Port Port X7 Status Actuator Port Port X6 Status Actuator Port Port X5 Status Actuator Port Port X4 Status Actuator Port Port X3 Status Actuator Port Port X2 Status Actuator Port Port X1 Status Actuator Port Byte offset Contents Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 n Port X8 Digital Input Pin 2 Port X7 Digital Input Pin 2 Port X6 Digital Input Pin 2 Port X5 Digital ...

Page 62: ...X3 Status Sensor Port Port X2 Status Sensor Port Port X1 Status Sensor Port n 20 Port X1 Sensor Current mA MSB n 21 Port X1 Sensor Current mA LSB n 22 Port X2 Sensor Current mA MSB n 23 Port X2 Sensor Current mA LSB n 24 Port X3 Sensor Current mA MSB n 25 Port X3 Sensor Current mA LSB n 26 Port X4 Sensor Current mA MSB n 27 Port X4 Sensor Current mA LSB n 28 Port X5 Sensor Current mA MSB n 29 Port...

Page 63: ...bytes 0x0000 0xFFFF Port Xn Status Actuator Port Status of the supply voltage UA of the port 1 bit 0x0 no error 0x1 error Port Xn Actuator Current mA Current intensity value of the supply voltage UA on pin 2 of the Xn port value in mA 2 bytes 0x0000 0xFFFF Port Xm Status Sensor Port Status of the supply voltage US of the port 1 bit 0x0 no error 0x1 error Port Xm Sensor Current mA Current intensity...

Page 64: ...ll firmware and electronic files are provided by ifm Port modules I O Mode Byte Contents 0 IO Link input data n bytes n Port Qualifier Information Mapping Port Qualifier Information PQI S 72 Byte Contents 0 IO Link output data m bytes Input data Output data Legend n Number of bytes on input data n 0 1 2 4 8 16 32 Legend m Number of bytes on output data m 0 1 2 4 8 16 32 ...

Page 65: ...eter update detected 0x1 IO Link device parameter detected SubstDev 1 bit 0x0 No exchange IO Link device detected identical serial number 0x1 Exchange IO Link device detected different serial number PortActive 1 bit 0x0 Disable the port via the port function 0x1 Port enabled DevComm 1 bit 0x0 no IO Link device available 0x1 IO Link device detected IO Link device in PREOPERATE or OPERATE mode DevEr...

Page 66: ...ion of the device r 2 Software revision prefix Prefix of the software revision of the device V R P U or T r 1 Software Revision Software revision numbers separated by blanks e g x y z in Vx y z r 3 Revision Counter Revision counter is incremented with each parameter change r 2 Profile ID ID of sub module profile Slot 0 0x0000 r 2 Profile Specific Type additional value for profile ID 0 if not used ...

Page 67: ...ware revision Hardware revision of the device r 2 Software revision prefix Prefix of the software revision of the device V R P U or T r 1 SOFTWARE_REVISION Software revision numbers separated by blanks e g x y z in Vx y z r 3 REVISION_COUNTER Revision counter is incremented with each parameter change r 2 Profile ID ID of the sub module profile Slot 1 0x4E01 IOLink r 2 Profile Specific Type additio...

Page 68: ...pply Diagnostics 0x21 EVNT_CODE_P_POWER Error in the power supply of the IO Link master Diagnostics 0x28 EVNT_CODE_DSREADY_NOACTION Data storage completed but no action since CRC was correct Alarm 0x29 DS_FAULT_IDENT Sensor does not match the content of the data memory Alarm 0x2A DS_FAULT_SIZE Sensor parameters too large for data memory Alarm 0x2B DS_FAULT_UPLOAD Error during data memory transmiss...

Page 69: ...bus Configure IP settings 24 Firmware Reboot the device 30 Reset device to factory settings 30 First access with LR DEVICE to the IO Link master 22 Function 8 G General 6 Ground the device 14 I I M datasets 66 I M0 Slot 0 66 I M0 Slot 1 67 I M1 Slot 0 66 I M2 Slot 0 66 I M3 Slot 0 67 Info Show device information 29 Inputs 50 Inputs outputs 50 Install GSD Files 32 Installing the device 10 Integrate...

Page 70: ...ion history 5 Mounting 10 N Notes 11 O Offline parameter setting 21 Online parameter setting 21 Operating and display elements 16 Operation 41 Outputs 50 Overview 16 P Parameter data 54 Parameter setting 8 Parameter setting options 19 Parameters of the IOLD proxy modules 58 Parameters of the IOLM proxy modules 55 Permitted use 7 Port modules I O Mode 56 Mix Mode 57 Preliminary note 4 PROFINET 8 32...

Page 71: ...ster 071 01 21 IO Link Master PROFINET NC MP 4A4B 12DLA AL1403 This device is powered by ifm In all electronic interfaces this device will appear as AL1403 All firmware and electronic files are provided by ifm Notes ...

Page 72: ...ren Buschjost FAS Herion Kloehn Maxseal and Thompson Valves are registered trademarks of Norgren companies Due to our policy of continuous development Norgren reserve the right to change specifications without prior notice OM_IO Link Master en 01 21 Selected Images used under license from Shutterstock com Disposal of this product is regulated by the EU WEEE Directive for waste electrical and elect...