7.5
Accessory Wiring
The manufacturer instructions that come with your accessory should have markings for wires or terminals
to connect to the gate opener. Please look for terminals named below in the instructions for the accessory.
Keypads, Receivers:
Normally Open (NO) or Input (INP) or Relay of entry device
= COM ter minal (to right of PUSH1) of PUSH
block on gate opener control board.
Common (COM) or Ground (GND) or Relay of entry device
= PUSH1 ter minal of PUSH block on gate
opener control board.
NOTE:
If the power for the accessor y shar es a Ground wir e/ter minal with the r elay – Do Not power that ac-
cessory off this control board (example: WKP-P keypad). Instead power that device with batteries.
24V Power positive (+) or (24V) or (PWR) of entry device
= +24V terminal of PHOTO block on gate opener
control board.
24V Power Negative (-) or (GND) or (PWR) of entry device
= GND terminal of PHOTO block on gate open-
er control board.
Push Button, Intercoms:
Normally Open (NO) or Input (INP) or Relay of entry device
= COM ter minal (to right of PUSH1) of PUSH
block on gate opener control board.
Common (COM) or Ground (GND) or Relay of entry device
= PUSH1 ter minal of PUSH block on gate
opener control board.
Push buttons do not require power and Intercoms draw too much power to power from the gate opener.
Exit Wand/Sensor, Exit Loop Detector, Exit Device:
Normally Open (NO) or Input (INP) or Relay of exit device
= COM terminal (to r ight of PUSH2) of PUSH
block on gate opener control board.
Common (COM) or Ground (GND) or Relay of exit device
= PUSH2 terminal of PUSH block on gate opener
control board.
24V Power positive (+) or (24V) or (PWR) of exit device
= +24V terminal of PHOTO block on gate opener
control board.
24V Power Negative (-) or (GND) or (PWR) or Shield wire of exit device
= GND terminal of PHOTO block
on gate opener control board.