First Run
5.1
This is our recommended procedure to run the gate for the first time.
PUSH 1 or PUSH 2 to increase or decrease the parameter. Then press SET button to move to the next
parameter.
1. Press SET button to begin.
2. LED shows P1:
Press Push 1 to get P1 setting to 30.
3. Press SET button.
4. LED shows P2:
Press Push 1 to get P2 setting to 10.
5. Press SET button.
6. LED shows P3:
Press Push 1 to get P3 setting to 30.
7. Press SET button.
8. LED shows P4:
Press Push 1 to get P4 setting to 3.
9. Press SET button.
10. LED shows P5:
Press Push 1 to get P5 setting to 2.
11. Press SET button.
12. LED shows P6:
Press Push 1 to get P6 setting to 10.
13. Press SET to finish. You should hear 3 beeps; this indicates parameter programming is finished.
Manually unlock the gate, then move it half-way and re-engage.
Activate using Push 1 button (as shown above) The gate should
run open. Press Push 1 again and it should run closed. The gate
is now set up for regular usage.