PO

PARTIAL OPENING:

It is possible to adjust the width of the partial leaf opening as a percentage of the total gate 
travel.
Adjustable from 0 to 99% in 1% steps.
 

00

 = no partial opening

 

01

 = minimum partial opening

 

99

 = maximum partial opening

50

t

TIME-OUT

It is advisable to set a value higher than the time taken by the gate to open or close fully.
Adjustable from

 0

 to 

59

 sec. in 1 second steps. Subsequently, display changes to minutes 

and tens of seconds (separated by a point) and time is adjusted in 10-second steps, up to 
the maximum value of 

9.5

 minutes.

E.g.: if the display shows 

2.5

, pause time is 2 min. and 50 secs.

            When using a system with MASTER/SLAVE configuration you must set a WORK TIME       
           on the MASTER unit that takes into account the movement time of both leaves.

2.0

o 1

OUT 1:

Allows output OUT (open collector N.O.) to be activated in one of the following functions:

00

 

= Always enabled (supplies 24V voltage= with a max absorption of 100 mA)

01

  = FAIL-SAFE (monitors the correct operation of the connected traditional photocells)

02

 = WARNING LIGHT (off when closed, on during opening and open/pause, flashing during closing)

03

 = COURTESY LIGHT (see next function)

04

 = ALARM, BATTERY operation

05

 = gate OPEN or PAUSED

06

 = gate CLOSED

07

 = gate in MOTION

08

 = gate OPENING

09

 = gate CLOSING

1 0

 = ACTIVE safety

1 1

  = timed output that can be activated by second radio channel (see next function)

1 2

 = output that can be activated by second radio channel (step function)

00

t1

TIMING OF OUT 1 (only if option 

03

 or 

11

 is selected at the previous step):

Can be used to adjust timing of output OUT if a timed function was selected 

(e.g. 

03 

or

 

11

) from 

1

 to 

99

 minutes in 1 minute steps.

02

Ob

OPEN B / CLOSE / EDGE SAFETY DEVICE:

It is possible to select the use of OPEN B input as partial opening, CLOSE command or EDGE 

SAFETY DEVICE.

 00

   

= OPEN B

 01

    

= CLOSE

     02

   

= SAFETY EDGE SAFETY (N.C. contact)

 If you select a function logic that involves the use of the CLOSE command (logic 

b

,

 

bC

,

 C

) this function will be preset to 

01

 and it will not be possible to change it.

00

SP

STOP / EDGE SAFETY DEVICE

It is possible to select the use of STOP input as STOP or EDGE SAFETY DEVICE.

 00

   

= STOP

     01

   

= SAFETY EDGE SAFETY (N.C. contact)

00

IP

PARTIAL REVERSE:

It is possible to set the reverse type (complete or partial) when an obstacle is encountered

or when a safety edge is triggered.

 

 

Y

 

 

=

 

Partial reverse activation. When an obstacle is encountered or when a safety edge 

is triggered the leaf reverses movement for approximately 2” and will then stop

 

 no

 

 

=

 

Partial reverse deactivation. When an obstacle is encountered or when a leaf safety 

edge is triggered it completely reverses movement and will place itself in open or 

closed position

no

Lc

MOTOR LOCK:

It is possible to select the use of the motor lock during battery operation:

 

Y

 

=

 

the motor lock continues to operate regularly even during battery operation

 no

 

=

 

when the system switches to battery operation, the motor lock remains open.

Y

Display

Function

Default 

1

Содержание E721

Страница 1: ...B GND OPEN B CLOSE STOP FSW OP GND FSW CL 24 F C C M A I N P E N L B A T T E R Y M O T O R L A M P L O C K L O C K L O C K P R I M T R A N S F S E C T R A N S F F C A R A D I O 1 R A D I O 2 E R R O R...

Страница 2: ...testing in a typical standard configuration all products built by FAAC S p A Bologna 01 12 2011 CEO A Marcellan 1 WARNINGS 2 2 LAYOUT AND COMPONENTS 2 2 1 COMPONENT DESCRIPTION 3 2 2 DESCRIPTION OF T...

Страница 3: ...ll upstream of the system a differential thermal breaker with adequate tripping threshold Connect the earth lead to the appropriate terminal Always separate power cables from control and safety cables...

Страница 4: ...15 V 60 Hz Power consumption from mains stand by 10 W Motor max load 10A Accessory power supply 24 V Accessory max current 24 V max 500 mA BUS 2EASY max 500 mA Environmental temperature 20 55 C Flashi...

Страница 5: ...7 7 7 7 7 7 7 7 7 7 7 7 7 7 72 2 2 230 V 115 V ENGLISH A Photocells that operate during CLOSING B Photocells that operate during OPENING C Photocells that operate during OPENING and CLOSING MOTOR RELE...

Страница 6: ...par 4 1 1 2 Cut off power to the board 3 Connect both cables of the BUS 2EASY accessories to the red terminal block J12 polarity irrelevant 4 Power the board 5 Quickly press the SETUP push button SW4...

Страница 7: ...fety device deactivated Connection of 1 pair of closing photocells with FAIL SAFE safety device activated Other safety devices Set in second level of programming o1 01 Other safety devices 4 2 TRADITI...

Страница 8: ...setting 2nd level o1 00 FAIL SAFE DISABLED 2nd level SP 01 INPUT 4 SAFETY EDGE SAFETY By setting 2nd level o1 00 FAIL SAFE DISABLED 2nd level Ob 02 INPUT 3 SAFETY EDGE SAFETY Other safety devices 4 3...

Страница 9: ...n press push button F to exit the program and store the parameters The display shows again the status of the automated system 1st LEVEL PROGRAMMING Display Function Default 1 dF DEFAULT 1 Configures t...

Страница 10: ...peed 1 0 maximum speed When the speed value has been changed it is advisable to perform a new SETUP see par 7 3 08 ro SLOWING DURING OPENING Adjusts the slowing space as a percentage of the total gate...

Страница 11: ...you want the closing photocells to lock movement and reverse it on disengagement Normally operation of the closing photocells immediately puts the gate into reverse when this function is off Y revers...

Страница 12: ...next function 12 output that can be activated by second radio channel step function 00 t1 TIMING OF OUT 1 only if option 03 or 11 is selected at the previous step Can be used to adjust timing of outpu...

Страница 13: ...EN 03 Stop then CLOSE 04 In PAUSE 05 During opening stage 06 During closing stage 07 FAIL SAFE in progress 08 BUS 2EASY device check in progress 09 Preflashing then OPEN 10 Preflashing then CLOSE 11 O...

Страница 14: ...ee of any obstacle by people or things 6 3 STORING LC RC RADIOCONTROLS It is possible to store a maximum of 256 codes divided between OPEN A and OPEN B CLOSE Use the LC RC remote controls only with a...

Страница 15: ...the cause of the error has been removed Fixed ON Mains powered Flashing Battery powered Off Board off Tab 3 Description of POWER LED 7 2 BATTERY OPERATION ATTENTION To optimise energy consumption and...

Страница 16: ...e LED for the FCA limit switch on the board goes off secure with the appropriate screws 4 Move the gate to closing position manually leaving 40 mm from the limit switch me chanical stop 5 Slide the ma...

Страница 17: ...erminal board POLE 1 POLE 2 see Fig 19 When a unit is configured as a SLAVE this will force the values of some programming parameters no longer displayed in the menu LO PA Pb Ph Op By placing the boar...

Страница 18: ...encoder will cause the motion to reverse At the next motion in the same direction an obstacle in the same position will cause the motor to stop It is essential to correctly configure this parameter to...

Страница 19: ...OP FSW OP FSW CL FSW CL OP CLOSED opens the gate opens the gate partially no effect no effect OPEN inhibited no effect OPEN inhibited no effect no effect OPEN inhibited DURING OPENING locks operation...

Страница 20: ...ses reclosesthegate noeffect OPEN CLOSEinhibited noeffect OPENinhibited noeffect CLOSEinhibited noeffect OPEN CLOSEinhibited LOGIC S PULSES STATUS OF AUTOMATED SYSTEM OPEN A OPEN B CLOSE STOP FSW OP F...

Страница 21: ...ED opensthegate closesthegate noeffect OPEN CLOSEinhibited noeffect OPENinhibited noeffect CLOSEinhibited noeffect OPEN CLOSEinhibited LOGIC B PULSES STATUS OF AUTOMATED SYSTEM OPEN A CLOSE STOP FSW O...

Страница 22: ...79 6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 35...

Отзывы: