7
ENGLISH
ADVANCED PROGRAMMING
Display
Function
dF01
Po
POSITION OF DOOR:
Shows the position of the door during motorised movement from
00
to
59
.
For an explanation of parameter
PO
refer to chapter
7.5
.
00
P1
UPPER LIMIT OF ZONE A:
Defines the upper limit of zone
A
, in which to subsequently adjust the force, speed and sensitivity functions of
the encoder
F1
,
S
1
,
E1
.
(input value
P1
as explained in chapter
7.5
).
20
P2
UPPER LIMIT OF ZONE B:
Defines the upper limit of zone
B
,
in which to subsequently adjust the force, speed and sensitivity functions of
the encoder
F2
,
S2
,
E2
.
(input value
P2
as explained in chapter
7.5
).
32
oF
OPENING FORCE:
Adjusts force during opening from
01
to
50
.
25
F2
CLOSING FORCE IN ZONE B:
Adjusts force during closing from
01
to
50
.
30
F1
CLOSING FORCE IN ZONE A:
Adjusts force during closing from
01
to
50
.
20
S2
CLOSING SPEED IN ZONE B:
Adjusts closing speed in zone B from
01
to
10
(
10
= max. speed,
01
= min. speed).
05
S1
CLOSING SPEED IN ZONE A:
Adjusts closing speed in zone A from
01
to
10
(
10
= max. speed,
01
= min. speed).
03
E2
ENCODER SENSITIVITY IN ZONE B:
Adjusts anti-crushing sensitivity in zone B from
01
to
50
(
50
= min. sensitivity,
01
= max. sensitivity).
04
E1
ENCODER SENSITIVITY IN ZONE A:
Adjusts anti-crushing sensitivity in zone A from
01
to
50
(
50
= min. sensitivity,
01
= max. sensitivity).
03
LP
COURTESY LIGHT:
To set lighted time of the courtesy light.
Can be adjusted from
0
to
59
sec in one-second steps.
Afterwards, the viewing changes in minutes and tenths of a second (separated by a dot) and time is adjusted
in 10 second steps, up to the maximum value of
4.1
minutes.
E.g. if the display shows
2.5
, the pause time will be 2 min and 50 sec.
30
Tab. 3