background image

14

OPEN B

OPEN A

RADIO SET UP

ENGLISH

 The 3 types of radio codes (DS, LSH, LC) cannot 

 coexist.

 

Only one radio code can be used at a time.

 

To change over from one code to another, you must 

delete the existing one (see paragraph on deletion), 

and repeat the memory-storage procedure.

 A maximum of two codes can be stored. One on the 

OPEN A channel and one on the OPEN B channel

1) On the DS radio control, select the required ON-OFF combination 

for the 12 dip-switches.

2) To respectively memory store total or partial opening, press 

the OPEN A or OPEN B push-button for one second (Fig. 31 

 ref. 

)

3) The relevant LED (Fig. 31 ref 

), begins to flash for 5 sec.

12.1. Memory storage of radio controls DS

Fig. 30

11.3 Pre-flashing

The pre-flashing function can be enabled and disabled 
(following an OPEN command, the unit activates the flashing
lamp for 5 seconds before it starts the movement). 
Procedure:
1)  Press and hold down the SET UP push-button.
2)  Press the OPEN push-button too after about 3 seconds. If the 

SET UP LED goes ON, pre-flashing was activated, if instead, 

it stays OFF, pre-flashing was disabled.

3)  Release both push-buttons.12. MEMORY STORAGE OF RADIO 

CONTROLS CODING

12. MEMORY STORAGE OF RADIO CONTROLS CODING

The control unit has an integrated 2-channel decoding system 

(DS, SLH, LC) named OMNIDEC. This system makes it possible to 

memory-store both total opening (OPEN A) and partial opening 

(OPEN B) of the automated system - this is made possible by an 

additional receiver module (Fig. 30 ref. 

) and radio controls 

on the same frequency.

4) Within these 5 secs., press the appropriate push-button on 

the radio control.

5) The relevant LED lights up on steady beam for 1 second and 

then goes OFF, indicating that storage was executed.

6) To add other radio controls, set the same ON - OFF combination

 used in point 1).

12.2. Memory storage of radio controls SLH

 A Maximum of 250 codes can be memory stored, split 

between OPEN A and OPEN B.

1) On the SLH radio control, simultaneously press and hold down 

push-buttons P1 and P2.

2) The radio control LED begins to flash.

3) Release both push-buttons.

4) To respectively memory store total or partial opening, press 

the OPEN A or OPEN B push-button for one second (Fig. 31 

ref. 

).

5) The relevant LED starts to flash slowly for 5 sec.

6) Within these 5 sec., while the radio control LED is still flashing, 

press and hold down the required push-button on the radio 

control (the radio control LED lights up on steady beam).

7) The LED on the board lights up on steady beam for 1 second 

and then goes OFF, indicating that storage was executed.

8) Release the radio control push-button.

9) Quickly press twice in succession the memory stored radio 

control push-button.

  The automated system performs one opening operation. 

Make sure that the automated system is free of any 

obstacle created by persons or things.

10) To add other radio controls, transfer the code of the 

  memory-stored push-button of the radio control to the 

relevant push-button of the radio controls to be added, 

observing the following procedure:

- On the memory stored radio control, simultaneously press and 

hold down push-buttons P1 and P2.

- The radio control LED begins to flash.

- Release both push-buttons.

- Press and hold down the memory-stored push-button (the radio 

control LED lights up on steady beam).

- Approach the radio controls to each other and hold down the 

push-button corresponding to the radio control to be added; 

then release it after a double flash of the radio control LED 

indicating that storage was executed.

Fig. 31

Содержание E1000

Страница 1: ...board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Settin...

Страница 2: ...install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise y...

Страница 3: ...ng 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poin...

Страница 4: ...ccess Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D1000 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Страница 5: ...ducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing mec...

Страница 6: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Страница 7: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Страница 8: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Страница 9: ...80 cm off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be move...

Страница 10: ...LOCKED Closes No effect 2 No effect 1 Supply voltage V Hz 230 50 Power supply to accessories Vdc 24 Accessories max load mA 200 Operating ambient temperature C 20 55 Quick fit connector for receiver b...

Страница 11: ...he input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Inputs status leds The automated system stopped and at rest is indicated in bold for each input STOP 1...

Страница 12: ...rent conditions and following commands or action by the safety devices Learning can be automatic or manual In the latter case the opening and closing deceleration points can be determined However in a...

Страница 13: ...UP LED starts to flash when you release the push button Start the following procedure within 4 seconds otherwise the operator will perform automatic SET UP 1 Give the 1st OPEN command the operator pe...

Страница 14: ...ond and then goes OFF indicating that storage was executed 6 To add other radio controls set the same ON OFF combination used in point 1 12 2 Memory storage of radio controls SLH A Maximum of 250 code...

Страница 15: ...EN A or OPEN B 5 The LED on the board relating to the channel being learned flashes for 5 sec within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam...

Страница 16: ...4 Fig 36 Fig 37 17 3 Safety edge CN60E The use of the safety edge with conductive element is facilitated because the control unit Fig 36 ref can be housed on board the operator Procedure Grip the rear...

Страница 17: ...ently reverses motion during the opening and or closing manoeuvre The automated system detects that the door movement is too difficult If you are using manual adjustment of force thesetthrustcouldbein...

Страница 18: ...ransmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the opening stage h...

Страница 19: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Страница 20: ...D1000 D1000...

Страница 21: ......

Страница 22: ...e un nuovo impulso di apertura Se viene rilevato un ostacolo in chiusura nella stessa posizione per tre volte consecutive l automazione assume tale quota come nuova battuta di chiusura e si pone in st...

Страница 23: ...oppia fotocellule 2 Dispositivo di comando 1 Dispositivo di comando 2 Radiocomando Lampeggiante Nr Data Descrizione intervento Firme 1 Tecnico Cliente 2 Tecnico Cliente 3 Tecnico Cliente 4 Tecnico Cli...

Страница 24: ...ransmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the opening stage h...

Страница 25: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Страница 26: ...actionne le moteur lectrique qui par l interm diaire de la transmission cha ne ou courroie entra ne la porte en position d ouverture et permet l acc s Si l on a s lectionn le fonctionnement automatiqu...

Страница 27: ...nicien Client Installateur Client Type d installation N de s rie Date d installation Activation COMPOSANT MOD LE N DE SERIE Op rateur Dispositif de s curit 1 Dispositif de s curit 2 Paire de photocell...

Страница 28: ...er empf ngt Abb 1 wird der Elektromotor in Betrieb gesetzt der das Tor ber einen Ketten oder Riemenantrieb ffnet und Zugang Zufahrt erm glicht Wenn der Automatikbetrieb eingestellt wurde schlie t sich...

Страница 29: ...hniker Kunde 10 Techniker Kunde Monteur Kunde Art der Anlage Seriennummer Installationsdatum Inbetriebnahme BAUTEIL MODELL SERIENNUMMER Antrieb Sicherheitsvorrichtung 1 Sicherheitsvorrichtung 2 Fotoze...

Страница 30: ...gundo impulso para obtener el cierre Un impulso de apertura durante la fase de apertura detiene el movimiento Un impulso de apertura durante la fase de cierre causa siempre la inversi n del movimiento...

Страница 31: ...e 10 T cnico Cliente Instalador Cliente Tipo de equipo N de serie Fecha de instalaci n Activaci n COMPONENTE MODELO N DE SERIE Operador Dispositivo de seguridad 1 Dispositivo de seguridad 2 Par de fot...