24 Vdc
max 3 W
ENGLISH
Fig.
F
F1
F2
J1
J2
J6
DL
–
+
Led
J7
Fig.
CONTROL BOARD 578D
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker
with adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the
J7 connector of the equipment (see fig.).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
TOTAL
OPEN
PARTIAL
OPEN
STOP
LIMIT-SWITCH
ENCODER
NB.: The capacitor is supplied with the operator.
230 Vac
(max. 60W)
230Vac
50-60Hz
For connection of the
photocells and safety
devices, see paragraph 4.1.
DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J
LOW VOLTAGE TERMINAL BOARD
J
CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER
J6
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
J7
230 Vac POWER SUPPLY TERMINAL BOARD
F
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)
F
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
"F" PROGRAMMING PUSH-BUTTON
–
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
Power supply V~ (+6% -0%)
230
Absorbed power (W)
10
Motor max. load (W)
1000
Accessories max. load (A)
0,5
Operating ambient temperature
-20 °C +55 °C
Protection fuses
2 (see fig. 1)
Function logics:
Automatic / “Stepped” automatic / Semi-automatic / Safety devices
/ Semi-automatic B / Dead-man C / “Stepped” semi-automatic / Mixed B/C logic
Work time
Programmable (from 0 to 4 min.)
Pause time
Programmable (from 0 to 4 min.)
Thrust force
Adjustable over 50 levels
Terminal board inputs:
Open - Partial Open - Opening safety devices - Closing
safety devices - Stop - Edge - Power Earth - Opening and closing
limit-switches - Encoder
Terminal board outputs:
Flashing lamp - Motor - 24 Vdc accessories power supply-
24 Vdc indicator-light / Timed output / Electric lock command - 'traffic lights' - Failsafe
Rapid connector
5-pin card connection for Minidec, Decoder or RP receivers
Programming
3 keys (+, -, F) and display, "basic" or "advanced" mode
Basic mode programmable functions:
Function logic - Pause time - Thrust Force
- Opening-closing direction
Advanced mode programmable functions:
Torque at initial thrust - Braking - Fail
safe- Pre-flashing - Indicator-light/Timed output/Electric lock or 'traffic lights' command
-Opening and closing safety devices logic - Encoder/ Anti-crushing sensitivity -
Decelerations - Partial opening time - Work time - Assistance request - Cycle counter
1 WARNINGS
2 TECHNICAL SPECIFICATIONS
3 LAYOUT AND COMPONENTS
4 ELECTRIC CONNECTIONS
Содержание E 578D
Страница 1: ...E 578D...
Страница 9: ...FC1 FC2 2 1 FC1 FC2 ENGLISH Fig 21 Fig 19 Fig 20...