5 PROGRAMMING
F
F
+
+
BASIC PROGRAMMING
Display Function
Default
FUNCTION LOGICS (see table of logics):
A
= Automatic
AP
= "Stepped" automatic
S
= "Safety" Automatic
E
= Semi-automatic
EP
= "Stepped" Semi-automatic
C
= Dead-man
b
= "B" Semi-automatic
bC
= Mixed Log. (B opening / C closing)
PAUSE TIME:
This has effect only if the automatic logic was
selected. Adjustable from
0
to
59
sec. in
one-second steps.
Subsequently, display changes to minutes and
tens of seconds (separated by a point) and time is
adjusted in 10-second steps, up to the maximum
value of
4,1
minutes.
E.g. if the display shows
2.5
, pause time is 2
min. and 50 sec.
To access ADVANCED PROGRAMMING, press key
F
and, as
you hold it down, press key
+
:
•if you release key
+
, the display indicates the name of the
first function.
•if you release key
F
too, the display shows the value of the
function that can be modified with keys
+
and
-
.
•if you press key
F
(and hold it down), the display shows the
name of the next function, and if you release it, the value that
can be modified with keys
+
and
-
is shown.
•when you reach the last function, press
F
to exit the program,
and the display resumes showing the gate status.
The following table shows the sequence of functions
accessible in ADVANCED PROGRAMMING:
To program operation of the automated system, you have
to access the "PROGRAMMING" mode.
Programming is split into two parts: BASIC and ADVANCED.
ADVANCED PROGRAMMING
Display Function
Default
MAXIMUM TORQUE AT INITIAL THRUST:
The motor operate at maximum torque (ignoring
the torque setting) at start of movement. Useful
for heavy leaves.
Y
= Active
no
= Disabled
FINAL BRAKING:
When the gate engages the opening or closing
limit-switch, a braking stroke can be selected
to ensure the leaf is stopped immediately. If
decelerations are selected, braking starts when
they finish.
At
00
value, braking is disabled.
Time can be adjusted from
01
to
20
in
0.01-second steps.
00
= Braking disabled
from
01
to
20
= Timed braking
To access BASIC PROGRAMMING, press key
F
:
•if you press it (and hold it down), the display shows the name
of the first function.
•if you release the key, the display shows the value of the
function that can be modified with keys
+
and
-
.
•if you press
F
again (and hold it down), the display shows the
name of the next function, etc.
•when you reach the last function, press
F
to exit the program,
and the display resumes showing the gate status.
The following table shows the sequence of functions
accessible in BASIC PROGRAMMING:
FORCE:
Adjusts Motor thrust.
0 1
= minimum force
50
= maximum force
STATUS OF AUTOMATED SYSTEM:
Exit from programming, save data, and return
to gate status viewing
00
= Closed
01
= Now opening
02
= At "STOP"
03
= Open
04
= Pause
05
= "FAIL SAFE" tripped
06
= Now closing
07
= Now reversing
08
= Photocells tripped
OPENING DIRECTION:
Indicates the gate opening movement and makes it
possible not to change the motor and limit-switches
connections on the terminal board.
-3
= Standard opening movement
E-
= Reverse opening movement
5.1 BASIC PROGRAMMING
5.2 ADVANCED PROGRAMMING
FAIL SAFE:
If this function is activated, it enables a function
test of the photocells before any gate movement.
If the test fails (photocells not serviceable signalled
by value
05
on the display), the gate does not
start moving.
Y
= Active
no
= Disabled
PRE-FLASHING (5 s.):
Activates the flashing lamp for 5 seconds before
start of movement.
no
= Disabled
oP
= only before opening
CL
= only before closing
OC
= before every movement