INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
13
Revision 3
• Connecting an encoder (electronic limit switch)
The EP105 supports DB405 type encoders. The encoder uses the same terminals as a conventional mechanical limit switch.
The two diagrams below illustrate how to connect the encoder, and also show which is the left and right motor from the point
of view of the automatic control unit. Make sure the cable to the encoder does not share the same buried pipe as the motor
power supply.
DB405
Motor 1
Left position
DB405
Motor 2
Right position
Control unit
14
17
1
2
3
1
2
3
34
L.O1
L.O2
GND
+24V
+24V
GND
GND
L.OUT
L.OUT
+24V
13
+24V
16
Motor 1 Left position
Motor 2 Right position
• Connecting a mechanical limit switch (microswitch)
Limit switch
Motor 1
Left position
Control unit
14
17
1
2
3
18
L.O1
L.O2
+24V
13
15
16
4
Limit switch
Motor 2
Right position
1
2
3
4
L.C1
L.C2
+24V
• Connecting timer control limit switches
Limit switches can still be used with timer control – they are connected as shown above (mechanical limit switch) but only
for the open position. If there is no limit switch, make the connections as shown below. A mechanical stop in the open
position must be fitted.
Control unit
14
17
18
L.O1
L.O2
+24V
13
15
16
L.C1
L.C2
+24V
Содержание DAAB EP105
Страница 1: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105...
Страница 58: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105 58 Revision 3 Notes...
Страница 59: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105 59 Revision 3 Notes...
Страница 60: ...Revision 3 FAAC Nordic AB Box 125 SE 284 22 Perstorp 46 435 77 95 00 www faac se support faac se...