4
DAAB RADIO CARD DB411 INSTRUCTION MANUAL
Revision 7
DB411, Description of operation of r-channels in automatic control units EP104 and EP105
You can use the DB411 add-in card to access four programmable radio inputs in the automatic control unit.
The instructions are identical for all four radio inputs, apart from the channel number – input 1 has channel number r1nn,
input 2 has channel number r2nn, etc. The settings below are for output 1.
Use channel r001 for a readout showing which radio channel is receiving a signal – the value displayed indicates the radio
input that is in use.
In the case of EP105, channel C711 must be set to 1 for the r-channels to be shown.
Control functions using radio inputs
Use the following r channels to select the radio signal function.
r160 Control function
Change the value in the channel to give the input the desired function. The value 1 means open, 2 means close, etc. See the
channel reference for all possible options.
r162 Half operation
Use this channel to specify whether you want motors 1, 2 or both to operate when the input is activated. 1 = motor 1, 2 =
motor 2 and 3 = both motors 1 and 2.
r163 Limited opening
EP104-1:
If you want limited opening, set this channel to the value 1, the door will then open according to the set time in C412 and
C414 when a limit switch is used or a specified number of degrees in L116 and L126 when an encoder is used.
EP105:
If you want limited opening, set this channel to the value 1, the door will then open according to the set time in C216 and
L226 when a limit switch is used or a specified number of degrees in L116 and L126 when an encoder is used.
r170 Block radio input from a programmable input
This channel is used to disable radio operation from a programmable input. Make sure that the programmable input is
active and that all the options for the input have been disabled. The value 1 will disable the radio input if there is no signal
at programmable input 1. Set the correct value for the programmable input you want to use.
r180 Park
Use this setting to allow the radio input to park the door. If the input is activated, the door opens, but before it can close a
new control signal is required at another input – regardless of the setting for automatic closing.
r190 Interlock opening
In an interlocking system, this input is used to send a command for the local door to open, and to pass on the open
command to the remote door.