INSTRUCTION MANUAL DAAB ENCODER DB405
3
• Left or right encoder position
In order for EP104 to determine that the motor is moving in the correct direction, the settings in L-channels must be made
correctly. To find out which drive unit to be left or right, see picture below. Top mounted drive unit with one motor should
be set as right.
L110=1, Motor 1 Left position
L120=2; Motor 2 Right position
L113, Closed position
L123, Closed position
L112, Open position
L122, Open position
L121, Position readout
L1
11, Position readout
• Connections
The Encoder terminals work as shown in the table below.
No
Function
1
Power supply 12-24 VDC
2
GND
3
Analog output to EP104
4-9 Free connection points, Max 24 VDC, the terminals have no function for the encoder.
• Light indication
To the left of terminal number 1 there is a LED indicator that lights green when the card is powered by 12-24 VDC.
Description of the magnet
The magnet that is mounted on the shaft has to be adjusted due to top mounted or side mounted drive unit. Before the magnet
adapter could be rotated the screw at the side of the adapter must be lossed. On a side mounted drive unit the arrow on the
magnet should point att the drive arm. On a top mounted drive unit the arrow should point away from the drive arm.