P a g e
|
4
Double Door Configuration – Master/Slave
If you are installing the operators on a double door, for the best result you will need to enable the
Master/Slave functionality of the 950N2. In order to do this, you will require the use of a KP Evo as
it is NOT POSSIBLE to achieve this otherwise under normal conditions.
STEP 1
Run through Steps 1 though to Step 7 as above, ensuring that the Motion Parameters (See below)
are identical between the two 950N2 operators.
STEP 2
Link the two 950N2’s together using a 3-Core Cable (ideally Shielded, CAT5e as used for the KP Evo
is suitable). Please ensure to check that DIPSWITCH “1” and “2” are in the “ON” position in the DS2
bank found in the I/O Board (See Step 5 above for location details).
Please note that Factory default is in the “OFF” position.
STEP 3
Plug the KP Evo into the operator that you designate to be the SLAVE (i.e. not receiving the opening commands).
Using the KP Evo, go to Spanner, Programming and then into Intercom (see below) and performing the following
configuration changes.
Set Function to “2 Leaves”.
Set Master/Slave Nr to “2 Slave”.
Unplug KP Evo from SLAVE and plug into MASTER.
STEP 4
Using the KP Evo, go to Spanner, Programming and then into Intercom (as above) and performing
the following configuration changes.
Set Function to “2 Leaves”.
Set Master/Slave Nr to “1 Master”.
In INTERCOM REG. select “YES” to perform INTERCOM REGISTRATION.
If wired correctly and DS2 set correctly as above, you should now be able to go into NODE LIST and
see “02” in the display.
STEP 5
Adjust LEAF DELAY as required (See below). KP Evp – Spanner, Programming, Installation.