18
ENGLISH
ENGLISH
5.3.
PROGRAMMING
To program operation of the automated system, use the
microswitches as shown below.
1
2
3
4
5 6 7
Logic
SW1
SW2
SW3
E1
ON
ON
ON
B
OFF
ON
ON
S2
ON
OFF
ON
E2
OFF
OFF
ON
A1
ON
ON
OFF
C
OFF
ON
OFF
S1
ON
OFF
OFF
A2
OFF
OFF
OFF
Pause time (sec) (1)
Logic
A1-A2-S2
S1
SW4 SW5
5
15
ON
ON
10
30
OFF
ON
30
60
ON
OFF
120
180
OFF
OFF
ON
OFF
Operation of indicator-light
Gate status
SW6
Closed
Opening/Open
Closing
ON
OFF
Steady light
Flashing lamp
Light
Off
Steady light
Pre-flashing (2)
SW7
Yes
ON
No
OFF
(1) Pause times include pre-flashing if any
(2) Pre-flashing begins 5” before every movement.
Ü
You must press the RESET push-button after every
programming job.
Function logics
The following are available:
A1/A2 = “Automatic”
S1/S2 = “Safety device”
E1/E2/B = “Semi-automatic”
C = “Dead man”
Operation of the automated system in the different logics
is indicated in Tables 5-6-7-8-9-10-11-12.
Pause time
Pause time is waiting time during opening before re-closing
when an automatic logic was selected.
Pause times include pre-flashing if any
Operation of indicator
-
light
Used to change the behaviour of the indicator
-
light at closing
by making it flash.
Pre-flashing
Flashing lamp pre-flashing time of 5 sec before any movement
can be selected. This warns anyone near the gate that it is
about to move.
PULSES
LOGIC A1
SAFETY DEVICES
no effect
freezes pause until
disengagement
reverses motion
no effect
no effect
STOP
no effect
stops the count
stops
stops
no effect
GATE STATUS
CLOSED
OPEN IN PAUSE
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens and re-closes
after pause time (2)
re-closes after 5" (3)
reverses motion
no effect
re-closes (2)
TABLE 5
LOGIC A1 (AUTOMATIC)
PULSES
LOGIC A2
SAFETY DEVICES
no effect
when disengaged,
re-closes after 5”
stops and reverses
at disengagement (2)
no effect
no effect
STOP
no effect
stops the count
stops
stops
no effect
GATE STATUS
CLOSED
OPEN IN PAUSE
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens and re-
closes after pause
time (2)
re-closes after 5" (3)
reverses motion
no effect
re-closes (2)
TABLE 6
LOGIC A2 (AUTOMATICA PLUS)
LOGIC S1
PULSES
GATE STATUS
CLOSED
OPEN IN PAUSE
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens and re-
closes after pause
time (2)
closes
immediately (2-3)
reverses motion
reverses motion
re-closes (2)
STOP
no effect
stops the count
stops
stops
no effect
SAFETY DEVICES
no effect
when disengaged,
re-closes after 5”
reverses motion
no effect
no effect
TABLE 7
LOGIC S1 (SAFETY DEVICE)
LOGIC S2
PULSES
STOP
no effect
stops the count
stops
stops
no effect
GATE STATUS
CLOSED
OPEN IN PAUSE
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens and re-
closes after pause
time (2)
re-closes
immediately (2-3)
reverses motion
reverses motion
re-closes (2)
SAFETY DEVICES
no effect
freezes pause until
disengagement
stops and reverses
atdisengagement (2)
no effect
no effect
TABLE 8
LOGIC S2 (SAFETY DEVICE PLUS)
TABLE 9
LOGIC E1 (SEMI-AUTOMATIC)
SAFETY DEVICES
no effect
no effect
reverses motion
no effect
no effect
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens (2)
re-closes (2)
reverses motion
stops
re-closes (when safety
devices are engaged,
it re-opens) (2)
STOP
no effect
no effect
stops
stops
no effect
PULSES
LOGIC E1
TABLE 10
LOGIC E2 (SEMI-AUTOMATIC PLUS)
SAFETY DEVICES
no effect
no effect
stops and reverses
at disengagement (2)
no effect
no effect
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN A - OPEN B (1)
opens (2)
re-closes (2)
reverses motion
stops
re-closes (when safety
devices are engaged,
it re-opens) (2)
STOP
no effect
no effect
stops
stops
no effect
PULSES
LOGIC E2
TABLE 11
LOGIC B (SEMI-AUTOMATIC)
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
LOGIC B
PULSES
OPEN A
opens (2)
no effect
no effect
no effect
completes
opening (2)
OPEN B (4)
no effect
closes(2)
no effect
no effect
completes
closing (2)
STOP
no effect
no effect
stops movement
stops movement
no effect
SAFETY DEVICES
no effect
prevents closing
stops movement
no effect
prevents
closing