4.3 M3 TERMINAL BOARD
4.3.1 f
lAShing
l
Amp
Terminals “
LAMP - LAMP
”. Use a flashing-lamp with steady light (flashing is produced by the control unit) on operating
voltage of 24 Vdc 15W max. It is recommended to connect the flashing lamp before programming the control unit,
because its phases are displayed. A 1.5 sec. pre-flashing steady light goes on during both opening and closing. When
the gate is open, the flashing-lamp is OFF, and only flashes when the closing safety devices are engaged for a maxi-
mum time of 10 sec, signalling that one is operating in the gate movement area, after which the flashing-lamp goes
OFF even with the closing safety devices still engaged.
4.3.2 m
OTOr
Terminals “
CHM1 - APM1
”. Connect, to these terminals, the motor with a power supply of 24Vdc 70W max.
4.4 TERMINAL BOARD M4
4.4.1 p
Ower
Supply
Terminals “
VAC - VAC
”. Connect, to these terminals, the secondary winding wires arriving from the toroidal transformer
with voltage of 22V~ 50 Hz. Power ON is indicated by the lighting up of LED
DL1
“
POWER
”.
4.4.2 Batteries (optional)
Terminals “
+BAT - - BAT
”. Connect the 2 buffer batteries (optional) to these terminals. When the control unit is powered,
it will keep the batteries charged. The batteries come into operation when the transformer does not supply power.
• For battery dimensions and characteristics, refer to the descriptions on the table in paragraph 2.
• Power supply provided by the batteries should be considered an emergency situation. The number of possible
manoeuvres depends on the quality of the batteries, the gate’s structure (weight, length, general conditions,
etc.), and on the time since power was cut, etc, etc.
Observe the battery supply polarity.
4.4.3 A
cceSSOrieS
Terminals “
+24 - -24
”. Output for power supply to 24Vdc outside accessories.
• Maximum load of accessories is 500 mA.
4.4.4 e
ArThing
An appropriate earthing terminal or cable. Earth connect the mains supplying 230V~.
• The connection is essential for correct operation of the control unit.
5. INSTALLING A RECEIVER CARD FOR REMOTE-CONTROL
The control unit is designed to house a 5-pin radio-receiver module. To install, cut out power and fit the module in the
appropriate
M5
connector inside the control unit.
To avoid damaging the receiver and thus irreparably impairing its operation, the receiver must be installed while
observing the fitting direction specified in paragraph 12 (Connection lay-out).
This done, observe the radio-receiver instructions for memory-storing the remote control. When the remote control has
been stored, it controls
START
just like any command device.
6. CONTROL LEDS
LED
ON
OFF
DL1
- POWER
Control unit supplied by transformer
No power supplied, or control unit supplied by
the buffer batteries
DL2
- STOP
Command inactive
Command enabled
DL3
- FSW-CL
Safety device free
Safety devices engaged
DL4
- FSW-OP
Safety device free
Safety devices engaged
DL5
- FCC
Closing limit switch free
Closing limit switch engaged
DL6
- FCA
Opening limit switch free
Opening limit switch engaged
• Indicated in bold: status of LEDs with the gate closed, control unit supplied by transformer, and limit-switches
connected.
• If the limit-switches are not used, the relevant contacts must be jumper connected and the
DL5
and
DL6
LEDs must always be ON.
Содержание 724 D-24V
Страница 9: ...ITALIANO 12 SCHEMA DI COLLEGAMENTO...
Страница 19: ...17 ENGLISH 12 CONNECTION LAY OUT...
Страница 29: ...27 FRAN AIS 12 SCH MA DE CONNEXION...
Страница 39: ...37 ESPA OL 12 ESQUEMA DE CONEXI N...
Страница 49: ...47 DEUTSCH 12 ANSCHLUSSPLAN...
Страница 59: ...57 NEDERLANDS 12 AANSLUITSCHEMA...
Страница 69: ...57 NEDERLANDS 12 AANSLUITSCHEMA...
Страница 73: ...note notes note notas anmerkung opmerkingen...
Страница 74: ...note notes note notas anmerkung opmerkingen...