17
ENGLISH
R
Fig. 13
TF1
TRANSFORMER.
J1
REMOVABLE LOW-VOLTAGE TERMINAL
STRIP
J2
REMOVABLE POWER TERMINAL STRIP
J3
LIMIT SWITCH CONNECTOR
J4
DECODER CONNECTOR
J5
CONNECTOR FOR FSW, SLAVE, RELAY
BOARDS
J6
CONNECTOR FOR NTC PROBE
J9
REMOVABLE TERMINAL STRIP
NETWORK POWER SUPPLY
P1
RESET PUSHBUTTON.
F1
F5A FUSE (MOTOR).
F2
T1.6 FUSE (ACCESSORIES).
DL1
OPEN IMPULSE LED (A/E/P LOG.)
DL2
CLOSE IMPULSE LED (P LOG.)
SAFETY CONTACT (A LOG.)
DL3
STOP IMPULSE LED
DL4
ALARM LED (PANIC)
DL5
OPENING LIMIT SWITCH LED
DL6
CLOSING LIMIT SWITCH LED
624 MPS CONTROL UNIT
A / E LOGICS CONNECTIONS
STOP
This word indicates a activating device with normally
closed contact, whose activation suspends the current
status of the beam (opening, pause or closing), until
another pulse is sent.
SAFETY
This word indicates all devices (photocells, sensitive
pneumatic safety edges, magnetic coils) with normally
closed contact, which interrupt the movement of the
beam whenever there is an obstacle within their range.
PANIC
This word indicates a activating device with normally
closed contact, which is activated in an emergency and
causes the beam to open, suspending its current status
(open) until the RESET pushbutton is pressed.
PROGRAMMING THE MICROSWITCHES
NOTE: WHENEVER YOU CHANGE THE MICROSWITCH
PROGRAMMING, PRESS THE RESET PUSHBUTTON AFTERWARDS.
(*) IMPORTANT!:
The R logic (remote) must be selected
only if there are two opposing barriers that work
simultaneously. (See paragraph "624 SLAVE CARD", below.)
OPERATION OF SAFETY DEVICES
In the A or E logics, it is possible to obtain two different
types of safety device operation, depending on the pause
times that are selected:
- PAUSE TIMES WITH LAMP PRE-FLASHING (10-20-30-40 sec):
the closing movement is stopped, then reversed on
disengagement.
- PAUSE TIMES WITHOUT LAMP PRE-FLASHING:(0-5-10-20 sec):
the closing movement is reversed at once.
ALARM CONDITION
It arises in the following cases:
1)
Enabling of anti-panic input.
2)
Activation of safety TIME-OUT device, which interrupts
the operation of the system when operating time
exceeds 30 sec.
3)
Simultaneous triggering of the two limit switches.
4)
Microprocessor reading anomaly (syncro).
The alarm condition is indicated by the quick flashing
(0.25 sec) of the Warning Light LED and of the warning
light (if connected).
In this condition, all the functions of the system are
disabled. Normal operation is restored only after the
cause of the alarm has been eliminated and the RESET
pushbutton has been pressed.
Fig. 14
1 2 3 4 5 6 7 8 9 10
111213 14 15 16 17
PE N L1
3
4
5
1
2
1
2
M
OPEN
NC
FX
NA
FX
FAAC
LAMP
24 VAC
MAX 5 W
VENTOLA
FAN
VENTILATEUR
LÜFTER
VENTILADOR
MOTOR
STOP
–
–
–
+
+
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
230 VAC +6%
-10% 50-60 Hz
24 Vcc
P LOGIC CONNECTIONS
Fig. 15
1 2 3 4 5 6 7 8 9 10
111213 14 15 16 17
PE N L1
M
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
NC
NA
FAAC
LAMP
24 VAC
MAX 5 W
MOTOR
STOP
–
–
+
OPEN
CLOSED
VENTOLA
FAN
VENTILATEUR
LÜFTER
VENTILADOR
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
230 VAC +6%
-10% 50-60 Hz
24 Vcc
{
1
2
3
4
5
6
Logic
SW1
SW2
A
ON
ON
E
OFF
ON
P
ON
OFF
R(*)
OFF
OFF
Deceleration
SW6
short
OFF
long
ON
Pausetime
SW3 SW4 SW5
(sec)
Ø
OFF
OFF
OFF
5
ON
OFF
OFF
10
OFF
ON
OFF
20
ON
ON
OFF
10
OFF
OFF
ON
20
ON
OFF
ON
30
OFF
ON
ON
40
ON
ON
ON
With 5 sec pre-flashing
DESCRIPTION OF TERMINAL STRIP
OPEN
This word indicates any activating device with normally
open contact, whose activation causes the beam to perform
an opening movement. In automatic and semi-automatic
logics, it controls both opening and closing movements.
CLOSE
This word indicates any activating device with normally
open contact, whose activation causes the beam to
perform a closing movement. (Present only in P logic).