455 D Control Board
455 D
RP 1418
RP 433 RC
Figure Q
This is used for rapid connection to RP receivers (see Fig.
Q). Connect the accessory with the components side facing
the inside of the card.
Insert and remove with power OFF.
1.4.4 Terminal Block J1 - Accessories (Fig. B)
OPEN A - “Total Opening” Command (N.O.):
Any pulse generator (push-button, detector, etc.) which, by closing
a contact, commands opening and/or closing of both gate leaves.
To install several full opening pulse generators, connect the N.O.
contacts in parallel.
OPEN B - “Partial Opening” Command (N.O.) / Closing:
Any pulse generator (push-button, detector, etc.) which, by closing
a contact, commands opening and/or closing of the leaf driven by
motor M1. In the
B
and
C
logics, it always commands closing of both
leaves. To install several partial opening pulse generators, connect
the N.O. contacts in parallel.
STP - STOP Contact (N.C.):
Any device (e.g. a push-button) which, by opening a contact, is able
to stop gate movement. To install several STOP devices, connect
the N.C. contacts in series.
NB:
If STOP devices are not connected, jumper connect the
STP terminals and -
.
CL FSW - Closing Safety Devices Contact (N.C.):
The purpose of the closing safety devices is to protect the leaf move-
ment area during closing. During closing, in the
E-A-S-EP-AP-SP
logics, the safety devices reverse the movement of the gate leaves,
or stop and reverse the movement when they are released (see
Ad-
vanced Programming in Section 13.5.2
). During the closing cycle in
logics
B
and
C
, they interrupt movement. They never operate during
the opening cycle. If the
closing safety devices
operate when the
gate is open, they prevent the leaf closing movement.
NB: If no closing safety devices are connected, jumper connect
terminals CL and -TX FSW (Fig. G).
OP FSW - Opening safety devices contact (N.C.):
The purpose of the opening safety devices is to protect the leaf move-
ment area during opening. During opening, in the
E-A-S-EP-AP-SP
logics, the safety devices reverse the movement of the gate leaves.
During the opening cycle in logics
B
and
C
, they interrupt movement.
They never operate during the closing cycle.
If the
opening safety devices
operate when the gate is closed, they
prevent the leaf opening movement.
NB: If no opening safety devices are connected, jumper connect
inputs OP and -TX FSW
(Fig. G).
– - Negative for power supply to accessories
+ - 24 VDC - Positive for power supply to accessories
Important:
Accessories max. load is 500 mA. To calculate current
draw, refer to the instructions for individual accessories.
-TX FSW - Negative for power supply to photocell transmitters
.
If you use this terminal for connecting the negative for supplying
power to the photocell transmitters, you may, if necessary, also use
the FAIL SAFE function (see
Advanced Programming in Section
13.5.2
).
If this function is enabled, the equipment checks operation of the
photocells before each opening or closing cycle.
1.4.5 Terminal Block J5 - Indicator-Light and Electric
Lock
W.L. - Power supply to indicator-light
Connect a 24 VDC - 3 W max. indicator-light, if necessary, between
this terminal and the +24V supply. To avoid compromising correct
operation of the system,
do not exceed
the indicated power.
LOCK - Power supply to electric lock
If necessary, connect a 12 VAC electric strike lock between this
terminal and the +24V power supply. Please refer to Chapter 16 for
Magnetic Lock connection.
1.4.6 Connector J2 - Rapid Connection to RP