background image

3

455 D Control Board

Figure B

1.4. 455 D Layout and Components

NB: Capacitors are supplied with the operator.

Important: Before attempting any work on the control 

board (connections, maintenance), always turn off 

power.

1. 455 D CONTROL BOARD

1.3 Electric Connections

J4

J1

J3

F1

F2

PE N L

MAIN

1

2

4

5

6 7 8

COM OP

M1

COM OP

M2 CL

LAMP

9 10 11 12 13 14 15 16 17 18 19

OPEN

A

B STP CL OP

FSW

-

-

-

+24V

+

+

-TX

FSW

20 21

W.L.

LOCK

J5

J2

F

22

23

24 25

FC

A1

FC

C1

FC

A2

FC

C2

+

STOP

OP_A

OP_B

FSWCL

FSWOP

FCC1

FCC2

FCA1

FCA2

J6

Figure A

F

F1

F2

J1

J2

J3

J4

J5

J6

DL

+

Power Supply

 115 V~ ± 10% or 230 V~ +6%  -10%   50/60 Hz

Absorbed Power

   

10 W

Motor Max. Load

   

800 W

Accessories Max. Load

 

0,5 A

Electric Lock Max. Load

 

15 VA

Ambient Operating Temperature Range

 

-4°F to +131°F

Protection Fuses

   

2 (see Fig. A)

Function Logics

: Semi-automatic / Automatic / Safety Devices / 

“Stepped” Semi-automatic / “Stepped” Automatic / “Stepped” Safety 

Devices  / Semi-automatic B / Dead-man C

Opening/Closing Time

 

Programmable (from 0 to 120 s)

Pause Time

 

 

Programmable (from 0 to 4 min.)

Closing Leaf Delay

 

Programmable (from 0 to 4 min.)

Opening Leaf Delay

 

2 s (can be excluded)

Thrust Force

:  

Adjustable on 50 levels for each motor

Terminal Board Inputs

: Open / Open Free Leaf / Stop / Limit-switch 

Opening Safety Devices / Closing Safety Devices / Power  

Earth.

Terminal Board Outputs

: Flashing Lamp / Motors / 24 VDC Acces-

sories Power Supply / 24 VDC Indicator-Light / Fail Safe / 12 VAC 

Electric Lock Power Supply

Programmable Functions

: Logic / Pause Time / Thrust Force / Torque 

at Initial Thrust / Opening and Closing Leaf Delay / Reversing Stroke 

/ Over-Pushing Stroke / Indicator-Light /  Pre-Flashing / Electric Lock / 

Fail Safe / Safety Devices Logic / Assistance Request / Detection Time 

of Obstacle or Contact Point

Learning Function

: Simple or complete work time learning, with or 

without Limit-switch and/or Gatecoder.

1.2. Technical Specifications

1.1 455 D Control Board Warnings

Please refer to Chapter 16 for AC power wiring 

guidelines

DL

  SIGNALLING AND PROGRAMMING DISPLAY

J1

   LOW VOLTAGE TERMINAL BLOCK

J2

   CONNECTOR FOR RP RECEIVER

J

3   

AC POWER SUPPLY TERMINAL BLOCK

J4

   MOTORS AND FLASHING LAMP CONNECTION TERMINAL BLOCK

J5

   INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK

J6

   LIMIT-SWITCH AND GATECODER TERMINAL BLOCK

F1

   MOTORS AND TRANSFORMER PRIMARY WINDING    

       FUSE (F 5A - 230V) (F 10A - 115V)

F2

   LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)

F     

“F”  PROGRAMMING PUSH-BUTTON

 –     

“–”  PROGRAMMING PUSH-BUTTON

+     

“+”  PROGRAMMING PUSH-BUTTON

24 VDC

3W

12 VAC

FCC2

LIMIT-SWITCH

OR GATECODER

230 VAC

50 Hz

or

115 VAC

60 Hz

VAC MAX.

60W

OPEN A

OPEN B

STOP

BLUE

BLUE

For connection 

of the photo-

cells and safety 

devices, see 

Section 13.4.1.

(800) 878-7829

www.FastGateOpeners.com

Содержание 455 D

Страница 1: ...455 D Control Board 800 878 7829 www FastGateOpeners com...

Страница 2: ...est 10 2 OPERATING MODES DETAILED DESCRIPTION 11 3 PREWIRED ENCLOSURE DIAGRAM 13 4 POWER AND ACCESSORIES CONNECTIONS 14 AC Power Wiring Guidelines 14 AC Power Connection 14 Magnetic Lock Connection 14...

Страница 3: ...afety Devices Closing Safety Devices Power Supply Earth Terminal Board Outputs Flashing Lamp Motors 24 VDC Acces sories Power Supply 24 VDC Indicator Light Fail Safe 12 VAC Electric Lock Power Supply...

Страница 4: ...nst the risk of impact and crushing Opening Closing Safety Devices Closing Safety Devices Opening Safety Devices Connection of ONE Pair of Closing Photocells and ONE Pair of Opening Closing Photocells...

Страница 5: ...e K Connection of ONE Pair of Opening Photocells Connection of ONE Pair of Opening Photocells and ONE Pair of Closing Photocells Connection of TWO Pairs of Closing Photocells Connection of ONE Pair of...

Страница 6: ...y prevent the leaf closing movement NB If no closing safety devices are connected jumper connect terminals CL and TX FSW Fig G OP FSW Opening safety devices contact N C The purpose of the opening safe...

Страница 7: ...e Learning OPERATING LOGICS see tab 3 a h If using hydraulic operators set force to maximum level 1 4 7 Terminal Block J6 Limit Switch or Gatecoder 1 5 1 Basic Programming To access BASIC PROGRAMMING...

Страница 8: ...d Differentfigurescorrespondtotheextra time compared to normal work time opening or closing whentheoutputcanbeused viaarelay to power a courtesy light Time can be adjusted from to sec in 1 sec steps a...

Страница 9: ...on or radio control 1 OPEN Slow down at opening of leaf 1 2 OPEN Leaf 1 stops at opening and leaf 2 begins its opening movement 3 OPEN Slow down at opening of leaf 2 4 OPEN Leaf 2 stops at opening and...

Страница 10: ...ress push button F to exit and save the programming The procedure is complete and the gate is ready to operate Notes The slow down pulse should be given before the gate reaches the positive stop to pr...

Страница 11: ...c e s a e l e r n o d n a s k c o L g n i n e p o D E K C O L 3 f a e l e h t s e s o l C t c e f f e o N d e l b a s i d N E P O t c e f f e o N t c e f f e o N d e l b a s i d N E P O E c i g o L S...

Страница 12: ...stops operation NB Effects on other active pulse inputs in brackets P A c i g o L S E S L U P S U T A T S E T A G A N E P O B N E P O P O T S S E C I V E D Y T E F A S G N I N E P O S E C I V E D Y T...

Страница 13: ...13 455 D Control Board 3 PREWIRED ENCLOSURE DIAGRAM 800 878 7829 www FastGateOpeners com...

Страница 14: ...ht ning Use a grounding rod if necessary A surge suppressor is recommended for additional protec tion AC Power Connection 1 Turn the circuit breaker for the AC gate operator power to OFF before connec...

Страница 15: ...ubject to misuse negligence or accident or has not been operated in accordance with FAAC Inter national Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or oth...