455 D Control Board
Figure B
1.4. 455 D Layout and Components
NB: Capacitors are supplied with the operator.
Important: Before attempting any work on the control
board (connections, maintenance), always turn off
power.
1. 455 D CONTROL BOARD
1.3 Electric Connections
J4
J1
J3
F1
F2
PE N L
MAIN
1
2
4
5
6 7 8
COM OP
M1
COM OP
M2 CL
LAMP
9 10 11 12 13 14 15 16 17 18 19
OPEN
A
B STP CL OP
FSW
-
-
-
+24V
+
+
-TX
FSW
20 21
W.L.
LOCK
J5
J2
F
22
23
24 25
FC
A1
FC
C1
FC
A2
FC
C2
–
+
STOP
OP_A
OP_B
FSWCL
FSWOP
FCC1
FCC2
FCA1
FCA2
J6
Figure A
F
F1
F2
J1
J2
J3
J4
J5
J6
DL
–
+
Power Supply
115 V~ ± 10% or 230 V~ +6% -10% 50/60 Hz
Absorbed Power
10 W
Motor Max. Load
800 W
Accessories Max. Load
0,5 A
Electric Lock Max. Load
15 VA
Ambient Operating Temperature Range
-4°F to +131°F
Protection Fuses
2 (see Fig. A)
Function Logics
: Semi-automatic / Automatic / Safety Devices /
“Stepped” Semi-automatic / “Stepped” Automatic / “Stepped” Safety
Devices / Semi-automatic B / Dead-man C
Opening/Closing Time
Programmable (from 0 to 120 s)
Pause Time
Programmable (from 0 to 4 min.)
Closing Leaf Delay
Programmable (from 0 to 4 min.)
Opening Leaf Delay
2 s (can be excluded)
Thrust Force
:
Adjustable on 50 levels for each motor
Terminal Board Inputs
: Open / Open Free Leaf / Stop / Limit-switch
Opening Safety Devices / Closing Safety Devices / Power
Earth.
Terminal Board Outputs
: Flashing Lamp / Motors / 24 VDC Acces-
sories Power Supply / 24 VDC Indicator-Light / Fail Safe / 12 VAC
Electric Lock Power Supply
Programmable Functions
: Logic / Pause Time / Thrust Force / Torque
at Initial Thrust / Opening and Closing Leaf Delay / Reversing Stroke
/ Over-Pushing Stroke / Indicator-Light / Pre-Flashing / Electric Lock /
Fail Safe / Safety Devices Logic / Assistance Request / Detection Time
of Obstacle or Contact Point
Learning Function
: Simple or complete work time learning, with or
without Limit-switch and/or Gatecoder.
1.2. Technical Specifications
1.1 455 D Control Board Warnings
Please refer to Chapter 16 for AC power wiring
guidelines
DL
SIGNALLING AND PROGRAMMING DISPLAY
J1
LOW VOLTAGE TERMINAL BLOCK
J2
CONNECTOR FOR RP RECEIVER
J
3
AC POWER SUPPLY TERMINAL BLOCK
J4
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BLOCK
J5
INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK
J6
LIMIT-SWITCH AND GATECODER TERMINAL BLOCK
F1
MOTORS AND TRANSFORMER PRIMARY WINDING
FUSE (F 5A - 230V) (F 10A - 115V)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
“F” PROGRAMMING PUSH-BUTTON
–
“–” PROGRAMMING PUSH-BUTTON
+
“+” PROGRAMMING PUSH-BUTTON
24 VDC
3W
12 VAC
FCC2
LIMIT-SWITCH
OR GATECODER
230 VAC
50 Hz
or
115 VAC
60 Hz
VAC MAX.
60W
OPEN A
OPEN B
STOP
BLUE
BLUE
For connection
of the photo-
cells and safety
devices, see
Section 13.4.1.
(800) 878-7829
www.FastGateOpeners.com