![FAAC 450 MPS Control Panel Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/faac/450-mps-control-panel/450-mps-control-panel_installation-instructions-manual_3109461008.webp)
15
ENGLISH
Table 3/b
Opens leaves and
recloses after pause time
CLOSED
No effect (OPEN inhibited)
Recloses leaves immediately
OPEN on PAUSE
Recloses leaf immediately
Reopens leaves immediately
Reopens
leaf
immediately
CLOSING
No effect (OPEN inhibited)
Closes the leaf/leaves
OPENING
Recloses leaves immediately
LOGICS
"S
"
GATE STATUS
OPEN-A
Stops opening and, when disengaged, closes
W.L.
on
on
on
No effect (OPEN inhibited)
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
STOP
OPEN-B
No effect (OPEN inhibited)
See paragraph 1.3
No effect
No effect
off
Recloses leaf immediately
CLOSED
No effect (OPEN inhibited)
Recloses leaves immediately
Recloses
leaf
immediately
CLOSING
STOPPED
LOGICS
"E
"
GATE STATUS
OPEN-A
No
effect
No effect (OPEN inhibited)
W.L.
on
flashing light
on
on
No effect (OPEN inhibited)
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
Stops closing and, when disengaged, opens
See paragraph 1.3
Stops opening and, when disengaged,
continues to open
No effect
No effect
off
STOP
OPEN-B
Stops
Table 3/c
No effect
PULSES
Stops opening and, when disengaged, closes
No effect (OPEN inhibited)
Freezes pause until disengagement (*1) (OPEN inhibited)
Opens single leaf and
recloses after pause time
Opens single leaf
No effect
Stops closing and, when disengaged, opens
flashing light
No effect (OPEN inhibited)
STOPPED
Stops
Stops opening and, when disengaged,
continues to open
No effect (OPEN inhibited)
No effect
Opens leaves
OPEN
No effect (OPEN inhibited)
No effect (OPEN inhibited)
Stops
LO
G
IC
S "EP"
PULSES
GATE STATUS
OPEN-A
No effect (if the gate must open, inhibits OPEN)
No effect (if gate must close, inhibits OPEN)
W.L.
on
flashing light
on
on
No effect (OPEN inhibited)
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
STOP
OPEN-B
Stops closing and, when disengaged, opens
See paragraph 1.3
No effect
No effect
off
Table 3/d
Opens
leaves
Opens single leaf
Stops
Recloses leaf/leaves immediately
Stops opening and, when disengaged, closes
No effect (OPEN inhibited)
No effect (OPEN inhibited)
Stops opening and, when disengaged,
continues to open
Inverts the direction
CLOSED
OPEN
Stops
No effect
STOPPED
CLOSING
OPENING
PULSES
Closes the leaf/leaves
No effect (OPEN inhibited)
Reopens leaves immediately
Reopens leaf immediately
Stops
OPENING
Table 3/a
Opens leaves and
recloses after pause time
CLOSED
Stops
Recloses leaves immediately
OPEN on PAUSE
Recloses leaf immediately
CLOSING
No effect (OPEN inhibited)
Closes the leaf/leaves
STOPPED
OPENING
LOGICS "A"
PULSES
GATE STATUS
OPEN-A
Stops opening and, when disengaged, closes
No effect (OPEN inhibited)
flashing light
on
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
STOP
OPEN-B
Stops closing and, when disengaged, opens
Stops opening and, when disengaged,
continues to open
No effect
off
W.L.
No effect (OPEN inhibited)
Opens single leaf and re-closes
after pause time
Freezes pause until disengagement (*1) (OPEN inhibited)
No effect
on
No effect
See paragraph 1.3
No effect
on
No effect (OPEN inhibited)
Reopens leaves immediately
Reopens
leaf
immediately
No effect
No effect (OPEN inhibited)