DESCRIPTION AND TECHNICAL SPECIFICATIONS

Table 1: 410 MPS Control unit technical specifications

Power supply

230 V(+6%-10%) - 50 Hz

Absorbed power

10 W

Max. motor load

800 W

Max. accessories load

0,25 A

Temperature range

-20 °C +55 °C

Fuses

N. 3 (see fig.1)

Operations logics

Automatic / Semi-automatic / Safety /

Automatic timer/ Step-by-step semi-automatic

Opening/closing time

Adjustable by trimmer (from 0-120 s)

Pause time

Adjustable by trimmer (from 0-240 s)

Closing leaf delay time

Adjustable by trimmer (from 0 -28 s)

Opening leaf delay time

2.5 s 

 

(Can be disabled through bridge)

Thrust force

Adjustable by trimmer

Terminal block inputs

Open/Stop/Opening safeties/

Closing safeties/ mains power +earth

Terminal block outputs

Flashing light - motors

24 Vdc accessories power supply

Quick connector

Decoding cards - RP 433 SL/DS

Microswitch programmable functions

Operating logics

Closing safeties  logics

LAYOUT AND ELECTRICAL WIRING

Fig. 1

Opening

photocells

A

A

A

B

B

Closing photocells

OPEN
TOT.

STOP

For the safety and fail-safe devices, see the “Safety devices”
section.

N.B.: The capacitors are provided with the operators.

Fig. 2

Warning: 

the max. accessory load is 250 mA. To calculate

absorption values, refer to table 2.

Safety devices

These are all devices (photocells, safety edges, magnetic
coils, etc.) with an N.C. (normally closed) contact which
activate if an obstacle obstructs the area protected by the

a

J1 terminal block

  (fig. 2)

:

Earth connection

N.

:

power supply 230 V~ ( Neutre )

L.

:

power supply 230 V~ ( Phase)

N.B.:

 For correct operation the card must be connected to the

system’s earth. Install a suitable differential magneto-thermal
circuit-breaker upstream of the system.

b

J2 terminal block

  (fig. 2)

LAMP.:

flashing light output ( 230 V ~

)

MOTOR 1

Open /Common/ Close: Motor 1 connection

Can be used in one-leaf application.
(leaf closing delay)

MOTOR 2

Close /Common/ Open: Motor 2 connection

Not to be used in one-leaf application.

N.B.

To check the operation of the equipment at the test

bench, a load must be connected on the MOTOR 1 input.

c

J3 terminal block:

 low voltage (fig. 2) used to connect all

accessories (see table 2).

30 Vdc

– accessories power supply negative
+ accessories power supply positive (+ 30 Vdc)

Caution:

 Before touching the electronic unit (connections,

programming, maintenance) always switch off the power
supply.

Opening, closing or opening/closing photocells

Fig. 3

a

b

c

d

f g h

l

k

j

e

i

N

L

J2

J3

J1

F1

F4

F2

DL4

DL5

DL3

DL1

DL2

  OPENING
LEAF DELAY
  DISABLE

  FAILSAFE
   ON-OFF

m

n

Intelligent Security & Fire Ltd.

Содержание 410 MPS

Страница 1: ... pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 2: ... installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the metallic parts Also earth the yellow green wire of the operator 15 T...

Страница 3: ...es section N B The capacitors are provided with the operators Fig 2 Warning the max accessory load is 250 mA To calculate absorption values refer to table 2 Safety devices These are all devices photocells safety edges magnetic coils etc with an N C normally closed contact which activate if an obstacle obstructs the area protected by the a J1 terminal block fig 2 Earth connection N power supply 230...

Страница 4: ...tch SW4 settings They do not engage during the opening cycle N B If closing safety devices are not connected jumper inputs OP and FSWTX fig 4 The purpose of the closing safety devices is to safeguard the zone in which the leaves move during the closing cycle B fig 3 If the Fail Safe function is not used see cabling at page 4 for connections of photocells Important for further information on the op...

Страница 5: ... 30Vcc OP CL FSW FSWTX Two pair of closure photocells connected Fig 4 A Fig 5 A Fig 6 A Fig 7 A Fig 8 A Fig 9 A Application examples The following are the commonly used connection arrangements disable fail safe No safety device connected One pneumatic edge connected as closing safety device and one connected as opening safety device 1 pair of closing photocells connected 1 pair of opening photocel...

Страница 6: ...adjusting trimmer Time is adjustable from 0 to 120 seconds h LEAF DELAY trimmer closing leaf delay adjusting trimmer Leaf delay time is adjustable from 0 to 28 seconds N B 1 If the opening closing time is less than the set delay time the delayed leaf closes at the end of the closing time 2 In one leaf application set the leaf delay time to minimum i Programmingmicroswitches j Fuse F1 5x20 5 A 250 ...

Страница 7: ... the TORQUE trimmer fig 1 ref 5 To reduce torque adjust the trimmer anticlockwise To increase torque adjust the trimmer clockwise In any event FAAC advises not to exceed a torque of 15 Kg measured on the outer edge of the leaf Toensureprecisetorqueadjustmentusealineardynamometer When the 410 MPS card is used on hydraulic operators the torque control device must be set to the maximum value by turni...

Страница 8: ...ffect OPEN inhibited OPENING No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect Stops No effect OPEN inhibited Closes leaf leaves No effect OPEN inhibited No effect No effect OPEN inhibited No effect STOPPED CLOSING OPEN Recloses leaves immediately Reopens leaves immediately PULSES OPENING CLOSING SAFETIE...

Страница 9: ...ps opening and when disengaged closes LOGICS AD PULSES GATE STATUS OPEN A OPENING CLOSING SAFETIES CLOSING SAFETIES OPENING SAFETIES STOP Table 3 e CLOSED OPEN on PAUSE CLOSING OPENING If held it remains in pause timer function No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect No effect No effect OPEN in...

Страница 10: ...licación todas las modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro tipo de exigencia de carácter constructivo o comercial FAAC S p A Via Benini 1 40069 Zola Predosa BO ITALIA Tel 051 6172411 Tlx 521087 Fax 051 758518 FAAC per la natura La presente istruzione è realizzata al 100 in carta riciclata Non disperdete nell ambiente gli imballaggi dei compone...

Отзывы: