23
AC Power Wiring Guidelines
1. Check local wiring codes in all cases and follow all
local building codes. Wiring and hookup should be
performed by qualified electricians/installers only.
2. AC power should be supplied from a circuit breaker
panel and must have its own dedicated circuit breaker.
This supply must include a green ground conductor.
3. Properly ground the gate operator to minimize or
prevent damage from power surges and/or lightning.
Use a grounding rod if necessary. A surge suppressor is
recommended for additional protection.
BLACK
RED (230V)
GREEN
WHITE
115V LINE
115V LINE
GROUND
NEUTRAL
115 V
230 V
TX
TX
RX
RX
PHOTO
OP
OPEN
DEVICES
PHOTO
CL
24VDC
RX PHOTO
24VDC
TX PHOTO
+ -
+ -
SHADOW
INPUT
TEST
BUTTON
24VDC
RX PHOTO
24VDC
RX PHOTO
a b
a b
PHOTO
OP
a
b
a
b
OPEN SAFETY MONITORED
CLOSE SAFETY MONITORED
-
+
-
+
PHOTO
CL
Monitored safety connections
The prewired enclosure comes with dedicated terminal
blocks for the connection of safety photocells that can be
monitored by the control board for presence and correct
operation. One closing and one opening photocells can be
connected to the dedicated terminals.
1. Connect the trasnsmitter photocell(s) to the 24VDC TX
PHOTO terminals as shown on the drawing
2. Connect the receiver photocell(s) 24V power to the
24VDC RX PHOTO terminals as shown on the drawing
3. For applications that need only closing safeties connect
the N.C. outputs of the photocell to the PHOTO CL termi-
nals and connect a jumper to the PHOTO OP terminals
4. For applications that need closing and opening safeties
connect the N.C. outputs of the photocells to the PHOTO
CL and PHOTO OP terminals. Program the FS paramenter
in advance programming to Y
IMPORTANT: The operator requires the connection of the
closing safety photocell to work.
TX
RX
PHOTO
OP
OPEN
DEVICES
PHOTO
CL
24VDC
RX PHOTO
24VDC
TX PHOTO
+ -
+ -
SHADOW
INPUT
TEST
BUTTON
24VDC
RX PHOTO
a b
a b
a
b
CLOSE SAFETY MONITORED
-
+
PHOTO
CL