manualshive.com logo in svg
background image

4

Solar Kit

BATTERY STATUS LEDS

The Battery Status LEDs (Fig. 2 ref. (5) ) indicate the level 

of charge on the battery. The indication is based only on bat-

tery voltage setpoints, which provides an approximation of 

the actual state of charge of the battery.
Battery Status LED indications.

LED

Indication

Battery Sta-

tus

Load-

Status

Green

Flashing 

Charging

ON

Green

Slow Flashing

Trickle Charge

ON

Green

On solid

Battery Full

ON

Yellow

On solid

Battery    Half 

Full

ON

Red

Flashing

Battery Low

ON

Red

On solid

Battery Empty

OFF

None

No LEDS On

No Battery 

OFF

Status LED (Fig 2 Ref (1) ) Error Indications

• Solar overload   

 

Flashing Red

• High Voltage Disconnect  

Flashing Red

• High Temperature Disconect 

Flashing Red

• Internal Damage 

 

Solid Red1

Battery Status LEDs (Fig 2 Ref (5) )  Error Indications

• High Voltage Disconnect  

R - G Sequencing

• High Temperature Disconnect   R - Y Sequencing
• Load Overload  

 

R&G - Y Sequencing

• Self-test Error   

 

R - Y - G Sequencing

STATUS LED

The Status LED (Fig. 2 ref. (1) ) indicates charging status 

and any existing solar input error conditions. The Status LED 

is on when charging during the day and off at night. The Sta-

tus LED will flash red whenever an error condition(s) exists. 

Status LED indications.

Color

Indication

Operating State

None

Off  (with heart-

beat¹)

Night

Green

On Solid  (with 

heartbeat²)

Charging

Red

Flashing

Error

Red

On Solid

Critical Error

¹ Status LED heartbeat indication flickers ON briefly every 

5 seconds

² Status LED heartbeat indication flickers OFF briefly every 

5 seconds

5. 

SOLAR CONTROLLER LED INDICATION

6. 

TROUBLESHOOTING

Note:
A solid red Status LED indicates that a critical fault has 

been detected. Critical faults typically indicate that the 

controller is damaged and requires service.

LED error indications can be interpreted as follows:
“R - G sequencing” means that the Red LED is on, then 

the Green LED is on, then Red LED is on....
“R&G - Y sequencing” means that both the Red LED and 

Green LED are on, then just the Yellow LED is on, then 

Red and Green LED are on....

Solar Overload

If the solar current exceeds the maximum solar rating, the 

controller will stop charging until the solar current returns 

to within its operational rating. 

High Voltage Disconnect

The battery voltage has exceeded the controller’s maxi-

mum regulation limit of 30.6V . The solar and load will be 

disconnected until the battery voltage decreases to the 

reconnect threshold of 28V.

High Temperature Disconnect

The heatsink temperature has exceeded 185 °F (85 °C)

and the solar and load is disconnected. The controller will 

automatically reconnect when the heatsink cools to 176 °F 

(80 °C).

Load Overcurrent

If the load current exceeds the maximum load current rat-

ing, the controller will disconnect the load.
The controller will attempt to reconnect the load two (2) 

times approximately 10 seconds apart. If the overcurrent 

condition remains after the first two (2) attempts, the fault 

must be cleared by removing and reapplying power.
This error can also indicate a reverse polarity on the bat-

tery. Check wiring.

Содержание 3352.1

Страница 1: ...nternational Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com West Coast Operations 357 South Acacia Avenue Unit 357 Fullerton CA 92831 E024U Solar Kit ...

Страница 2: ...nel power 30 W Max solar input voltage 60 Vdc Max Solar current 10A 20A Battery nominal voltage 24Vdc Maximum Load Current 10A 20A Operating ambient temperature 4 F 131 F Protections short circuit over current reverse polarity high temperature high voltage SEALED OR FLOODED SELECT LOAD BATTERY SOLAR Remove Jumper Wire for Flooded Battery 12 V BATTERY STATUS TEMP SENSOR CHARGING STATUS See Operator...

Страница 3: ...r panel Connect the battery to the corresponding terminal block with the suppled cable Make sure to folow the polarity SOLAR PANEL BATTERY 12V 12V If the solar panel has enough exposure to light the green Status LED will be ON Turn the Control Board power ON using the circuit breaker If the battery voltage is below 26V the board will turn on right away if the battery voltage is above 26V the board...

Страница 4: ... briefly every 5 seconds Status LED heartbeat indication flickers OFF briefly every 5 seconds 5 SOLAR CONTROLLER LED INDICATION 6 TROUBLESHOOTING Note A solid red Status LED indicates that a critical fault has been detected Critical faults typically indicate that the controller is damaged and requires service LED error indications can be interpreted as follows R G sequencing means that the Red LED...

Страница 5: ... FLOODED SELECT 24 V 4 3 2 1 6 5 S O L A R C O N T R O L L E R SS 10L Nominal Rating 24Volts dc SolarIn 10A Load 10A SeeOperator s Manual E1 1220 4 UL 1604 CSA2 2 2 No 213 M198 7 Cl I Div 2 GP ABCD Haz Loc Voc 13 5Vdc BATTERY STATUS CHARGING STATUS SETTING J24 SOLAR PANEL BATTERY ...

Страница 6: ...nal Inc will return the warranted item freight prepaid The products manufactured by FAAC S p A and distributed by FAAC International Inc are not warranted to meet the specific requirements if any of safety codes of any particular state municipality or other jurisdic tion and neither FAAC S p A or FAAC International Inc assume any risk or liability whatsoever resulting from the use thereof whether ...

Отзывы: