This solar kit allows to use the E024U control board with the 

power. generated by a solar panel. Thanks to the high per-

formance built in solar charger/controller the battery can be 

charged quickly and reliably while the low power idle mode on 

the E024U allows for smooth operation
Due to the different power requirements of different operator 

types we have two versions of this kit:
3352.1 Kit for Electromagnetic operators
3353.1 Kit for Hydraulic operators

1

2

3

4

5

6

7

1. Connections Terminal Block 
2. Solar Controller 
3. Circuit Breaker 
4. Activation Push Button 
5. Accessories DIN Rail 
6. E024U Control Board 
7. Battery

1. 

DESCRIPTION AND CHARACTERISTICS

2. 

TECHNICAL SPECIFICATIONS

3. 

CHARGER / CONTROLLER FEATURES

Solar Kit

Fig. 1

+

BATTERY

SOLAR

LOAD

+

+

{

Remove

Jumper

Wir e for

Flooded

Battery

SEALED

OR

FLOODED

SELECT

24  V

4

3

2

1

6

5

S O L A R   C O N T R O L L E R   SS-10L

Nominal Rating

24 Volts    dc
Solar In   10A
Load       10A
       See Operator’s

          Manual

E1

1220

4

UL  1604

CSA2 2.2  No.  213-M198 7

Cl I, Div 2,

GP  ABCD

Haz. Loc.

Voc =13.5Vdc

BATTERY STATUS

SETTING

+

J24

CHARGING STATUS

3352.1

3353.1

Nominal system voltage

24 Vdc

Solar panel power

30 W

Max. solar input voltage

60 Vdc

Max Solar current

10A

20A

Battery nominal voltage

24Vdc

Maximum Load Current

10A

20A

Operating ambient temperature

-4°F    +131°F

Protections 

short circuit, over-current,reverse 

polarity, high temperature, high 

voltage

SEALED

OR

FLOODED

SELECT

LOAD

BATTERY

SOLAR

Remove

Jumper

Wire for

Flooded

Battery

{

12 V

BATTERY STATUS

TEMP. SENSOR

CHARGING STATUS

!

See Operator’s      
  

Manual

Nominal Rating

12 Volts dc

Max. Input  30 V

Solar  6.5 A

Battery 6.5 A

Load 10.0 A

indoor use only

Use Copper 

Conductors Only

CONFORMS TO UL STD 1604 

CERTIFIED TO CAN/CSA STD 

C22.2 NO.213-M1987

Class 1 Division 2

Groups A,B,C,D

Hazardous Loc.

For the Risk of Explosion Only

Operating Temp. Code: T5

MORNINGSTAR

S S

6

UN AVER-

SOLAR CONTROLLER SS-6-12V

1

2

5

4

3

1. Status LED
An LED indicator that shows charging status and also 

indicates when a solar input fault condition exists.
2. Power Terminal Block
Power terminations for system Solar, Battery, and Load 

connections.
3. Battery Select Jumper
A removable jumper to select the battery type.
4. Local Temperature Sensor
Measures ambient temperature. Battery regulation is ad-

justed based on ambient temperature changes.
5. Battery Status LEDs
Provides approximate battery state of charge indication 

and also indicates when a system or load fault condition 

exists.

Fig. 2

Содержание 3352.1

Страница 1: ...nternational Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com West Coast Operations 357 South Acacia Avenue Unit 357 Fullerton CA 92831 E024U Solar Kit ...

Страница 2: ...nel power 30 W Max solar input voltage 60 Vdc Max Solar current 10A 20A Battery nominal voltage 24Vdc Maximum Load Current 10A 20A Operating ambient temperature 4 F 131 F Protections short circuit over current reverse polarity high temperature high voltage SEALED OR FLOODED SELECT LOAD BATTERY SOLAR Remove Jumper Wire for Flooded Battery 12 V BATTERY STATUS TEMP SENSOR CHARGING STATUS See Operator...

Страница 3: ...r panel Connect the battery to the corresponding terminal block with the suppled cable Make sure to folow the polarity SOLAR PANEL BATTERY 12V 12V If the solar panel has enough exposure to light the green Status LED will be ON Turn the Control Board power ON using the circuit breaker If the battery voltage is below 26V the board will turn on right away if the battery voltage is above 26V the board...

Страница 4: ... briefly every 5 seconds Status LED heartbeat indication flickers OFF briefly every 5 seconds 5 SOLAR CONTROLLER LED INDICATION 6 TROUBLESHOOTING Note A solid red Status LED indicates that a critical fault has been detected Critical faults typically indicate that the controller is damaged and requires service LED error indications can be interpreted as follows R G sequencing means that the Red LED...

Страница 5: ... FLOODED SELECT 24 V 4 3 2 1 6 5 S O L A R C O N T R O L L E R SS 10L Nominal Rating 24Volts dc SolarIn 10A Load 10A SeeOperator s Manual E1 1220 4 UL 1604 CSA2 2 2 No 213 M198 7 Cl I Div 2 GP ABCD Haz Loc Voc 13 5Vdc BATTERY STATUS CHARGING STATUS SETTING J24 SOLAR PANEL BATTERY ...

Страница 6: ...nal Inc will return the warranted item freight prepaid The products manufactured by FAAC S p A and distributed by FAAC International Inc are not warranted to meet the specific requirements if any of safety codes of any particular state municipality or other jurisdic tion and neither FAAC S p A or FAAC International Inc assume any risk or liability whatsoever resulting from the use thereof whether ...

Отзывы: