FAA Approved Installation Manual for the EDM-960 system
Report No 909
Primary Engine Data Management System
Page 32 of 45 Rev C
Date 12-12-12
32. Pilot Programmable Mode
Refer to the Pilots Guide for specific Pilot Programming details. Basically to start the Pilot Program procedure,
simultaneously hold the STEP and LF buttons for five seconds. You will see the word PROGRAM for two seconds and
then the example sequence shown in the chart below.
Tap the STEP button to advance to the next item in the list. Hold the STEP button to step back to the previous item.
Tap the LF button to select alternate values of that item. Simultaneously hold both STEP and LF to exit.
STEP
advances
next item
LF
sequences
through
these
values
Comments
PROGRAM
Stays on for two seconds.
FUEL N
FILL? N
Tap LF to change fuel status. Exits program mode when done.
RATE 4
0 … 9
Index rate (pause time in seconds) in the Automatic Mode. 0 disables the Automatic
Mode.
OAT F
OAT
F
OAT
C
To calibrate the OAT
10°, hold both the STEP and LF buttons simultaneously for five
seconds, which will proceed to the next step. Otherwise the next step will be skipped.
OAT
0
OAT-I0 …
OAT
I0
This step will be normally be skipped.
Adjust the indicated temperature up or down by up to 10°. For example, OAT
3
adjust the OAT 3° higher.
EGT I?N
EGT I?N
EGT ICY
Y—Yes—sets the digital display to one-degree resolution; N—No—sets 10°. (10°
resolution is easier to interpret the Get’s.)
HIP I25
70 HP
HIP= I25
%HP display will change when HP constant is adjusted. Hold STEP and LF for 5
seconds until you see ADJUST to set the HP calibration. Tap STEP to continue to the
next step. See page 26
To adjust the MAP, hold both the STEP and LF buttons simultaneously for five
seconds, which will proceed to the next step. Otherwise the next step will be skipped.
MAP 29.9
MAP 20
32
Adjust the MAP. See page 33
KF 29.90
Adjust the instrument’s K-factor to match the fuel flow transducer K-factor. See page 33
TR IP? N
TR IP?
N
TR IP?
Y
N—No—Upon informing the EDM that you refueled the aircraft, reset total fuel used to 0.
Y—Yes—accumulate total fuel used rather than reset to 0 at each refueling. See page
33
HOBS VAL
2424
ENG
25
EDM
3567
FRM
Displays the engine hours and airframe hours.
END? Y
END?
Y
STEP exits the pilot programming mode.
LF reenters pilot programming mode.