![F5 ARX-VE Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/f5/arx-ve/arx-ve_planning-manual_3096206047.webp)
Physical Site Preparation
ARX Site Planning Guide
1 - 41
ARX-2000 System Specifications and Requirements
The following table describes the ARX-2000 system specifications:
Environmental Requirements
Altitude: 60m (197ft) min. to 1800m (6000 ft) max.
Humidity
Operating: 10% min. to 95% max. (non condensing)
Storage: 5% to 95%
Temperature
Operating: 32 deg. to 104 deg. F (0 deg. to 40 deg. C)
Storage: -40 deg. to 149 deg. F (-20 deg. to 65 deg. C)
Table 1.7
ARX-2000 System Specifications
Component
Specification
Chassis Dimensions
(includes front bezel)
Height: 3.5 in.
Width: 19.00 in. (including mounting ear assemblies)
Depth: 24 in.
Chassis Weight
40 lb (18.14 kg)
Power Consumption
Typical power consumption:
2.5A @ 110VAC (280W; 0.98 PF)
Maximum power consumption:
8.4A @ 100VAC (maximum rated current)
450W (maximum rated power)
AC/DC Power Supply
700 Watts
1+1 redundancy
> 80% efficiency
Input: 100VAC – 240VAC, 47/63HZ
Output: -12V @ 1A, +3.3V @ 32A, +5V 30A, +12V 62A
Environmental Requirements
Altitude
-200 ft. (-60 m) min. to 8000 ft. (2500 m) max.
Humidity
Operating: 5 % min. to 95% max. (non condensing)
Storage: 5% to 95%
Temperature
Operating: 41 deg. to 95 deg. F (5 deg. to 35 deg. C)
Storage: -4 deg. to 149 deg. F (-20 deg. to 65 deg. C)
Table 1.6
ARX-1500 System Specifications (Continued)