background image

Page 4.

E-Z-GO Division of Textron, Inc., 1451 Marvin Griffin Road, Augusta, Georgia

USA 30906-3852 Phone: 1-800-241-5855

MAINTENANCE INSTRUCTIONS

1. For flooded lead-acid batteries, regularly check

water levels of each battery cell after charging and
add distilled water as required to level specified by
battery manufacturer. Follow the safety instructions
recommended by the battery manufacturer.

2. Make sure charger connections to battery terminals

are tight and clean. Check for deformation/cracks in
plastic parts. Check the charger harness for chaffing
and rubbing. Inspect all wiring for fraying, loose ter-
minals, chaffing, corrosion or deterioration of insula-
tion.

3. Keep cooling fins free of contamination and do not

expose charger to oil, dirt, mud or to direct heavy
water spraying when cleaning equipment.

710-0035 Rev1

Introducing the

PowerWise

 

QE

     48 Volt Battery Charger

Содержание PowerWise QE

Страница 1: ...1451 Marvin Griffin Rd Augusta GA 30906 800 241 5855 706 798 4311 Introducing the 48 Volt Charger 710 0035 Rev1 ...

Страница 2: ... fabricant de la batterie p ex vérifier s il faut enlever les bouchons des cellules lors du chargement de la batterie et les taux de chargement recommandés Information de Sécurité Électrique Risque de chocs électriques Ne pas toucher les parties non isolées du con necteur de sortie ou les bornes non isolées de la batterie Toujours con necter le chargeur à une prise de cou rant mise à la terre Ne p...

Страница 3: ...pletely charged The charger may now be unplugged from the vehicle If left plugged in and the battery pack voltage drops below a minimum volt age or 30 days has elapsed the charger will auto matically restart a complete charge cycle 6 If a fault occurred anytime during charging a fault indication is given by quickly flashing the RED LED on the charger The specific fault is indicated on the charger ...

Страница 4: ...ety instructions recommended by the battery manufacturer 2 Make sure charger connections to battery terminals are tight and clean Check for deformation cracks in plastic parts Check the charger harness for chaffing and rubbing Inspect all wiring for fraying loose ter minals chaffing corrosion or deterioration of insula tion 3 Keep cooling fins free of contamination and do not expose charger to oil...

Страница 5: ...Page 5 E Z GO Division of Textron Inc 1451 Marvin Griffin Road Augusta Georgia USA 30906 3852 Phone 1 800 241 5855 Notes Introducing the PowerWise QE 48 Volt Battery Charger 710 0035 Rev1 ...

Отзывы: