INSTRUCTION MANUAL
SWD® Starter Kit
Page
16
on
24
V-EN_2021_SWD® Starter Kit
5.6.
SWD safety hub connectors
The SWD and Scanner connectors of the SWD safety hub follow the pinouts of the above-described connectors.
Emergency stop connector
The Emergency stop connectors are of type M8 4-pin A coded.
They are used to connect the two normally closed switches of an E-Stop button (2NC type).
Pin #
Designation
1
SW1 NC1
2
SW1 NC2
3
SW2 NC1
4
SW2 NC2
Switch ON and Batt ON connectors
The Switch ON and Batt ON connectors are of type M8 3-pin A coded.
They are used to forward the ON button signal to the activation signal of the battery.
Pin #
Designation
1
SW
3
GND
4
NC
6.
Mechanical assembly
6.1.
Dimensions of the packaging and contents of the pack
For all engine logistics operations alone, preferably use the original packaging.