background image

EZ Way, Inc.

EZ Way, Inc. • (800) 627-8940 • Fax (712) 542-1899 • www.ezlifts.com

13

Smart Lift

®

 Trouble-Shooting Guide

Problem

Solution

Machine will not turn on

Check battery. Make sure it is fully charged.

Check battery receiver plug. Make sure prongs are not bent or pushed 
in. Call EZ Way Service for replacement.

Check fuses.

Check green connector on PC board for good connection. Make sure 
all wires are tight.

Make sure on/off button is not flattened out.

Check if green LED is flashing on board. Flashing LED indicates the 
PCB is getting power.

Make sure W6 jumper is in place.

No up/down but display works

Check connection at actuator.

Check voltage at actuator connection. If 24 VDC are present then the 
actuator may need replaced.

If voltage is not good, check black and orange wires on green 
connector at circuit board. Make sure they are not loose.

Call Service if voltage is not good and connection is good.

Continuous up/down

Unhook toggles and airlines from board. If problem still persists call EZ 
Way Service.

Содержание Smart Lift L500

Страница 1: ...Service Manual Model L500 and L600 Smart Lift Form 1 144 Rev 2 5 19 WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Страница 2: ...Fax 712 542 1899 www ezlifts com Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 5 Smart Lift Operating Instructions 7 Scale Calibration 8 Advanced Smart Lift Features 9 Wiring Sche...

Страница 3: ...EZ Way Inc EZ Way Inc 800 627 8940 Fax 712 542 1899 www ezlifts com 3 L500 L600 Parts Diagram...

Страница 4: ...ader Bushing Kit 17 12014 Actuator Assembly Lift 18 12706 Hand Control Assembly 19 12146 Bed Guard 20 12788 Base Assembly Lift 500 lb Std Casters 600 EZ Smart Lift Model L600 Item Part No Description...

Страница 5: ...ce the bushings immediately The hanger spreader and sling hanger wear points need to be checked for wear If hooks appear worn call EZ Way for instructions BASE PIVOT REAR WHEEL FRONTWHEEL LINKAGE SPRE...

Страница 6: ...ing properly Hair that gets picked up and wrapped in between wheels should be cleaned out so that the lift will roll easily Do a visual check for any damaged missing or loose parts Repair as necessary...

Страница 7: ...bol indicating that the weight is recalled MENUS Navigating through menus 1 Pressing the Up or Down keys will move also described as scrolling below through menu items 2 Pressing the Right Toggle Swit...

Страница 8: ...sure the scale is functional 5 Enter the calibration menu After power up sequence press and hold the DOWN key followed quickly by the UP key and hold both keys for 5 seconds 6 Press the UP key to cali...

Страница 9: ...tomer will need to wait 15 minutes to cool the actuator motor Actuator Overload For Arm Protection 1 When an Up or Down command is executed the circuit board monitors current consumed by the actuator...

Страница 10: ...e since the last inspection exceeds 30 days a reminder message will appear when the unit is powered up The purpose of the inspection reminder is to notify the customer that the lift or stand needs to...

Страница 11: ...is read only information provides customer feedback for accidental lifting of a trapped sling accidental lifting of arm against obstruction or accidental lifting of overweight patient Lift Stand Total...

Страница 12: ...EZ Way Inc EZ Way Inc 800 627 8940 Fax 712 542 1899 www ezlifts com 12 Smart Lift Wiring Schematic...

Страница 13: ...ke sure on off button is not flattened out Check if green LED is flashing on board Flashing LED indicates the PCB is getting power Make sure W6 jumper is in place No up down but display works Check co...

Отзывы: