WWW.EYYES.COM
CAREYE
®
SAFETY ANGLE - TURN - ASSIST
INSTALLATION AND INSTRUCTION MANUAL
22
D
Electrical connection
MONITORS - MON1 AND MON2
■
Connect the signal line of the monitors to the configured ports
MON1 (turn assistant right) and MON2 (turn assistant left) of the
TIC box.
■
Connect the voltage supply of the monitors to the TATIC voltage
supply cable set.
■
The cable for the power supply of the monitor can be shortened.
After shortening, mount the 3-pin plug connector. The spring clips
enable easy mounting without tools.
■
Ensure that the plug connections are securely held, use the strain
reliefs.
PIN
DESCRIPTION
COLOR WIRES
1
Ground
Blach (shield)
2
nc
Not connected
3
Ignition Plus
Red (Inner conductor)
PIN1
Locking clips
Strain relief signal cable
Strain relief Voltage supply