Preference
The communication to the first device is defined on this page.
Communication Settings
Use local area network
With an Ethernet connection between the PC and
the first device
•
Socket
Standard 7992
•
First device IP Address
IP address of the
connected device (the first device)
•
Each device has a network board
With an
Ethernet connection when each device has its
own network card.
•
Apply changes
Accepts the new settings
You can check on the
Reports
page if the
connection is active.
Use serial port
With an RS232 interface connection between the
PC and the first device
(this is the standard communication gateway)
•
Serial Port
COM port used
•
Baud rate
Standard is 115200
•
Bits
Standard is data = 8, stop = 1
•
Parity
Standard is None
•
Apply changes
Accepts the new settings
You can check on the
Reports
page if the
connection is active.
Color analyzer option
Probe model
Selects a predefined colour probe
Communication port
Communication Port determines the serial port
to which the analyser is connected to. The other
adjustment options depend on the used colour
analyser. Here the operating instructions of the
devices have to be observed.
Percentage of tolerance
of the measures
Tolerance of the measure values.
Display the gradient
colour into the gamma
page
Not available
Pattern generator
Running on machine
(name or IP address)
Enables a connection to gccPattern. The IP
address or the name of the computer must be
entered into the network field. If the network has
no DNS service the IP address has to be fed here.
EYE-LCD-4600/5500-M-USN-LD-BC
55
Version 1.0 | Oktober 2014