![eyeLock NanoFace Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/eyelock/nanoface/nanoface_system-users-manual_2457591013.webp)
eyelock.com
NanoFace™ from eyeLock
User Guide, v1.0.6
January 2022
Copyright 2022, all rights reserved
Page 13 of 38
Recommended mounting height
Typical
Mounting bracket (optional)
2.1.2. Electrical Requirements
☑
Use a stable power supply adapter and cabling in accordance with Table 2 below.
Minimum current is 2.0 A. (Maximum actual voltage is 25 V DC.)
Note: usage of 12V DC is possible if there is no voltage drop due to either cable loss or
fluctuations in mains (AC) power. Please contact EyeLock for more information.
☑
It is preferrable that the power cable is as short as possible. Ensure that wire gauge is
correct in accordance with Table 2.
☑
Use CAT5 or better for Ethernet cable.
Table 2. Power requirements depending on cable length and wire gauge
Input voltage
(V)
Wire gauge
(AWG)
Power cable length (m)
Note
Recommended Maximum
15
20
25.0
37.5
Standard Configuration
22
15.7
23.6
24
20
70.1
105.1
22
44.0
66.0