6. PROGRAMMING AND USING THE CONTROLLER 

  CAUTION! Set the controllers output mode to “OFF” (see section 6.9) to ensure no ballasts will be 

accidentally activated during the controller setup.
Follow the actions listed below to quickly start using the controller.
1.  Set the controller output level. (see section 6.1)

2.  Program a light cycle. (see section 6.3)

3.  Set the output mode of the controller to “Follow” or “Inverse.” (see section 6.4)

4.  Set the auto-dim temperature. (see section 6.6)

5.  Set the shutdown temperature. (see section 6.7)

6.  Set sunrise/sunset period (optional). (see section 6.8)

7.  Activate the auto mode on the controller. (see section 6.9)

6.1 Adjust Ballast Output to Change Light Intensity

The controller can set the output of a ballast between 50% and 115%. Adjusting this ballast output enables 

the user to change the light intensity in the climate room.
1.  Press the DIMMING key. The Output Level Screen opens.

2.  Press the UP/DOWN keys to set the ballast output between 50% and 115% (400W, 600W and 750W 

systems can only be boosted up to 110%)

3.  Press ENTER to confirm your choice.

Note: The output level can also be found in the main menu.

6.2 Control a Lamp with a Lower Power Rating than its Ballast

 WARNING! When installing a lamp with a lower wattage than its ballast setting, ALWAYS adjust the 

output level of the ballast before switching the system on. Failing to do so will cause immediate damage to 

the lamp. A ballast may be used to control a lamp with a lower power output than the nominal value of the 

ballast. For example, a 1000 watt ballast set at 750 watt can be used to control a 750 watt lamp. To prevent 

damage to the light, the controller output must be adjusted to the appropriate value. Failing to properly 

set the wattage could result in risk of harm to person or property and may damage the lamp or ballast.
1.  Disconnect the ballast(s) from the main power supply.

2.  Make sure the display mode of the controller is set to represent the output power of your ballast, NOT 

of your lamp.

 

(see section 5.3)

3.  Adjust the ballast output to match the wattage of the lamp. (see section 6.1)

4.  Exchange the lamps of all connected ballasts.

5.  Reconnect the ballast to the main power supply.

6.3 Programming a Light Cycle

Press ENTER. The controller menu will open.
1.  Press the UP/DOWN keys to locate “light cycle” 

and press ENTER. The Light Cycle Screen will open. 

 

In this screen, the hour indication behind “ON” blinks 

(Figure 12A).

2.  Press the UP/DOWN keys to select the hour on which the 

lights must be activated and press ENTER to confirm your 

choice.

3.  Use the same procedure to set the minute (Figure 12B) on 

which the lights must be activated and the hour (Figure 

12C) and minute (Figure 12D) on which the lights must be 

deactivated. 

A

B

C

D

Содержание GRC1

Страница 1: ...GRC1 CONTROLLER USER MANUAL www eyehortilux com...

Страница 2: ...down of all connected equipment The alarm contact of the controller can be connected to your alarm system for instant notification You can connect up to one hundred systems to one controller and contr...

Страница 3: ...100 External Contactor Modules 2 optional Weight 0 55 lbs 0 25 kg Dimensions 3 40 86 4 mm 4 13 104 8 mm 1 35 34 3 mm 1 1 Contents A Master controller I Mounting plate B Manual C 120 240V AC 5V DC pow...

Страница 4: ...ate up in menu increase value E Up Navigate back in menu cancel reset Key Function A Power ON OFF power indicator A blinking green light indicates a power interruption has occurred during operation B...

Страница 5: ...EEM2 output is active when main channel is off F Cage clamp alarm Normally Open contact potential free G RJ9 4P4C Auxiliary port for controlling up to 50 ballasts H 3 5 mm port auxiliary temperature s...

Страница 6: ...rranties express or implied including any warranty of merchantability or fitness for a particular purpose In the event of a breach of warranty EYE Lighting International of North America EYE Lighting...

Страница 7: ...in Plug the sensor in completely Note If the message sensor failure appears the sensor is defective Replace the sensor 4 3 Connecting Equipment Which Must Be Used During Lights off Periods Example a...

Страница 8: ...onnect cable with RJ14 plugs Up to 50 ballasts may be daisy chained in this way 6 Plug system s back into the main power supply 4 6 Connecting the Controller to Complete Systems WARNING The controller...

Страница 9: ...lizing the Controller 1 Selecting your default language The controller can be set to five languages Dutch English German French and Spanish a Press ENTER the controller menu will open b Press the UP D...

Страница 10: ...le temperature sensor 4 Use the UP DOWN keys to switch between T1 or T2 and press ENTER to select the temperature value you wish to adjust 5 Use the UP DOWN keys to adjust the temperature to the desir...

Страница 11: ...ts ballast setting ALWAYS adjust the output level of the ballast before switching the system on Failing to do so will cause immediate damage to the lamp A ballast may be used to control a lamp with a...

Страница 12: ...ty Settings When the temperature in a climate room gets above a certain value the planted crops will start to degrade If this rise in temperature occurs it is desirable to dim or shut down the lights...

Страница 13: ...to 30 minutes 0 minutes indicates no ramp UP DOWN time 4 Press ENTER to confirm your choice 6 9 Activate or Deactivate the Systems Manually or Set Automatic Mode WARNING When replacing a lamp setting...

Страница 14: ...key when in the default screen to show the system time 2 Press the up key again to return to the default screen 7 3 Interpreting LED Signals GREEN LIGHT Figure 15A A glowing green light indicates the...

Страница 15: ...e has been exceeded the message auto dim will appear on the display The red light will also flash The flashing will continue until the temperature drops 0 5 C 0 9 F below the auto dim temperature for...

Страница 16: ...Visit eyehortilux com for the latest installation instructions 16 8 OVERVIEW OF ALL SCREENS ON DISPLAY Failures Temperature Sun Tim...

Страница 17: ...www eyehortilux com 17 Sunrise Sunset Time...

Страница 18: ...d alarme du contr leur peut tre connect votre syst me d alarme pour un avertissement instantan Vous pouvez connecter jusqu cent syst mes un contr leur et contr ler deux salles distinctes jusqu 50 syst...

Страница 19: ...asts 100 Modules de contacteurs externes 2 en option Poids 0 55 lbs 0 25 kg Dimensions 3 40 86 4 mm 4 13 104 8 mm 1 35 34 3 mm 1 1 Sommaire A Contr leur principal II Plaque de montage C Manuel D 120 2...

Страница 20: ...ugmenter les valeurs E Haut Naviguer vers l arri re dans les menus annuler r initialiser Touche Fonction A Courant Indiquelamisesoustensionouhorstension Unvoyantvertclignotantindiquequ uneinterruption...

Страница 21: ...est active lorsque le canal principal est d sactiv F Alarme de rappel de cage contact normalement ouvert potentiel libre G RJ9 4P4C Port auxiliaire permettant de contr ler jusqu 50 ballasts H Capteur...

Страница 22: ...parera ou remplacera sa seule discr tion le produit non conforme ou remboursera le prix d achat dans un d lai raisonnable EYE Lighting ne saurait tre tenue pour responsable de tout dommage indirect c...

Страница 23: ...rage 1 Connectez le c ble EEM aux bornes de rappel de cage marqu es EEM2 Figure 7 2 Connectez l quipement auxiliaire qui doit tre activ pendant les p riodes d extinction de l clairage au c ble EEM bra...

Страница 24: ...et EYE HORTILUX car les syst mes complets ne disposent que d unseulportRJ14 1 R glez le bouton rotatif de tous les syst mes EYE HORTILUX sur EXT 2 Branchez l extr mit RJ9 du c ble de contr leur fourni...

Страница 25: ...ENTER pour ouvrir le menu du contr leur e Appuyez sur les touches UP DOWN pour localiser les unit s de temp rature et appuyez sur ENTER L cran Unit s de temp rature s affichera f Appuyez sur les touc...

Страница 26: ...ion automatique voir section 6 6 5 R glez la temp rature de mise hors tension Voir section 6 7 6 D finir la p riode de lever coucher du soleil facultatif Voir section 6 8 7 Activer le mode automatique...

Страница 27: ...ment clair es La p riode ON OFF s lectionn e sera d finie pour le canal principal Le canal auxiliaire fonctionne l inverse du canal principal 6 5 R glage des param tres de s curit de la temp rature Lo...

Страница 28: ...votre choix 6 9Activeroud sactiverlessyst mesmanuellementour glerlemodeautomatique AVERTISSEMENT Lors du remplacement d une lampe r gler le ballast sur OFF pour outrepasser l horloge est insuffisant T...

Страница 29: ...vert allum indique que le contr leur fonctionne Un voyeur vert clignotant indique que le courant a t interrompu Apr s une panne de courant le voyant vert clignotant doit tre r initialis 1 Maintenez le...

Страница 30: ...de 0 5 C 0 9 F sous la temp rature d att nuation automatique pendant au moins 30 secondes Un voyant rouge allum indique que la temp rature d att nuation automatique a t d pass e dans le pass Pour r s...

Страница 31: ...temas a un controlador y controlar dos habitaciones separadas hasta 50 sistemas cada una utilizando el sensor de temperatura de cada una de ellas para la atenuaci n autom tica en temperaturas elevadas...

Страница 32: ...antidad de balastos 100 M dulos contactores externos 2 opcional Peso 0 25 kg 0 55 lb Dimensiones 3 40 86 4 mm 4 13 104 8 mm 1 35 34 3 mm 1 1 Contenido A Controlador maestro II Placa de montaje C Manua...

Страница 33: ...ar valores E Back retroceder Sirve para volver hacia atr s en el men cancelar o reiniciar Bot n Funci n A Alimentaci n Indicasilaalimentaci nest ENCENDIDA APAGADA Unaluzverdeintermitenteindicaquehubou...

Страница 34: ...ma cepo la salida est activa cuando el canal principal est apagado F Alarma de borne clema cepo contacto normalmente abierto sin potencial G Puerto auxiliar RJ9 4P4C de control de hasta 50 balastos H...

Страница 35: ...de un tiempo razonable EYE Lighting no estar obligada ni ser responsable de ning n da o indirecto consecuente o incidental por incumplimiento de esta u otra garant a expresa o impl cita o por reclamo...

Страница 36: ...1 Conecte el cable EEM a los bornes clema cepo marcados como EEM2 figura 7 2 Conecte el equipo auxiliar que deba activarse durante los periodos de luces apagadas al cable EEM conectado a los bornes m...

Страница 37: ...todos los sistemas EYE HORTILUX a EXT 2 Conecte el extremo RJ9 del cable del controlador provisto al puerto principal RJ9 del controlador 3 Conecte el extremo RJ14 del los cable s del controlador a la...

Страница 38: ...ones UP DOWN para seleccionar Temp Units Unidades de temperatura y presione ENTER Se abrir la pantalla de Temperature Units f Presione los botones UP DOWN para elegir entre C y F Presione ENTER para c...

Страница 39: ...ura de atenuaci n autom tica vea la secci n 6 6 5 Configure la temperatura de apagado vea la secci n 6 7 6 Configure un periodo de salida puesta del sol opcional vea la secci n 6 8 7 Active el modo au...

Страница 40: ...5 Configure el intervalo de luz en periodos de 12 horas vea la secci n 6 3 para asegurarse de que ambas c maras climatizadas obtengan la mismaluz ElperiododeENCENDIDO APAGADOelegidoseconfiguraparaelc...

Страница 41: ...e ENTER para confirmar su elecci n 6 9 Activaci n o desactivaci n de los sistemas de forma manual o configuraci n del modo autom tico ADVERTENCIA Al reemplazar una l mpara no es suficiente configurar...

Страница 42: ...Vuelva a presionar el bot n Up para regresar a la pantalla Default 7 3 Interpretaci n de las se ales de luz led LUZVERDE figura 15A Cuando la luz verde est encendida esto indica que el controlador est...

Страница 43: ...resione el bot n BACK durante 3 segundos AUTO DIM Cuandoseexcedelatemperaturadeatenuaci nautom tica aparecer elmensaje Auto Dim Atenuaci nautom tica enlapantalla Asuvez la luzrojaparpadear Estaluzcont...

Страница 44: ...of Iwasaki Electric of Japan 9150 Hendricks Road Mentor Ohio 44060 Tel 877 905 2562 Fax 800 81 1 7395 support eyehortilux com www eyehortilux com HORTILUX isatrademarkofIwasakiElectricCo andisregiste...

Отзывы: