Operating Manual
7
If using crimped stranded core cable;
Minimum cross section of cable = 0.25mm
2
Maximum cross section of cable = 1.5mm
2
IMPORTANT!
All cables should be connected to the iWAP300 via the correct
cable gland, fitted by a competent person.
IMPORTANT!
Changes in the design and modifications to the equipment are not
permitted. This includes adding heaters/fans which are not
installed at the factory.
Important
The installer MUST ensure that that all cables have adequate
mechanical protection to avoid damage to the wires.
3.1.3 Mains Variant Cable Installation
Diagram 3.1.2 shows the connectors on the mains variant of the iWAP300. Table
3.1.3 describes the pin out connection required for operation. There are two blocks of
screw terminals and one RJ45 connector. The Ethernet input screw terminals are
wired in parallel with the RJ45 connector. Do not make an Ethernet connection to the
RJ45 connector and the screw terminals at the same time, the installer should use
only one of these connectors.
Follow the instructions in section 3.1.2 to correctly prepare the cables and feed them
through the correct cable gland. Follow table 3.1.3 to connect the correct cable to the
correct screw terminal. If using the RJ45 connector instead of the screw terminals
simply connect the Cat-5 cable to the connector and ensure the cable is securely in
place.
Caution
Only ever make one Ethernet cable to either the RJ45 connector or
Ethernet screw terminals – NEVER both.