Operating Manual
11
Important
Only connectors 24VDC Input, Chassis Earth and Ethernet Input
(Terminals or RJ45) are user serviceable. The end user should not
connect, disconnect or alter the wiring on any other connector!
Caution
When powering the iWAP300 via POE do not apply an external power
supply to the protection board.
Caution
Never power the iWAP300 (if fans and/or heaters are installed) via POE.
3.1.6 Fibre Ethernet Input
Important When connecting the access point via a fibre connection do not use
any of the two Ethernet inputs of connectors.
To obtain greater wired link distances the iWAP300 can be shipped with an optional
fibre module. The fibre module will be connected directly to the access point, the user
should attach the fibre cable directly to the fibre module using a multimode fibre
cable on an ST connector.
3.1.7 Thermostat Control
The thermostats are currently not user configurable. The default configuration is for
the heaters to be turned on when the internal ambient temperature is between -20
o
C
and +10
o
C and for the fans/wireless hardware to be on above 1.5
o
C
3.1.8 Fitting the antennas
•
Connect the antennas to the correct the N type connector on the outside of the
enclosure (see Diagram 3.1.1). Make sure to only connect antennas which are
intended to be used at the frequency required (i.e. either 2.4GHz or 5.8GHz
antennas).
•
Depending on the options ordered some of the N-types may have been
replaced with blanking plugs or surge arrestors.
•
If the version ordered contains both a mesh router and access point; the mesh
router and access point should be setup in software to run at 5.8GHz and
2.4GHz respectively. The iWAP300 will be wired in this way when delivered.
•
The iWAP300 may be used with any antenna. It is recommended to use the
Extronics iANT200 series of antennas as these have already been pre-
approved for use with the iWAP300.
IMPORTANT!
Do not exceed the Effective Isotropic Radiated Power (EIRP) for
the
country/region of
operation.
Also when using the
iANT100/iANT101 do not exceed the maximum EIRP for the gas
group the iWAP300 is located in according to the standard BS
6656:2002 table 2.