3.4

 

Technical data for base/charging station 

 

 

Ambient temperature for 
base station:  

-20°C to +50°C 

Bluetooth: 

iSCAN211 and iSCAN211PDF: 

Bluetooth V2.1 EDR, Class 2 
2.4…2.4835 GHZ (ISM band) 

iSCAN2012D: 

Bluetooth V4.0 EDR, Class 1 
2.4…2.4835 GHZ (ISM band) 
 

Terminal assignment 
(Handheld scanner) 

 

USB cable 

RS232 cable 

USB/D+ green 
USB/D- white 
GND black 
+UB brown 

RS232-TXD white 
GND brown 
+UB yellow 

 

 

 

 

Nominal values of 

hazardous area base 

station: 

 

maximum input voltage 

Ui 

4.9 V 

 

maximum input current 

li 

480 mA 

 

maximum input power 

Pi 

1.25 W 

 

maximum internal inductance 

Li 

negligible 

 

maximum internal capacitance 

Ci 

112.4 µF 

 

 

 

 
If using a power supply other than iSCANPSx: 
 

 

maximum input voltage 

Ui 

5.6 V 

 

maximum input current 

li 

480 mA 

 

maximum input power 

Pi 

1.25 W 

 

maximum internal inductance 

Li 

negligible 

 

maximum internal capacitance 

Ci 

46 µF 

 

Note: The input voltage in to the handheld scanner itself is reduced by the 

associated connection cable ISCAN2XXCAB7 or 8 to 4.9V. 

 

Nominal values of safe 
area base station: 

 

 

operating voltage 

5V 

 

power requirement 

85 mA in standby mode 

 

Содержание iSCAN2012D

Страница 1: ...nt 18 Middlewich Cheshire UK CW10 0HU Tel 44 0 845 277 5000 Fax 44 0 845 277 4000 E mail info extronics com Web www extronics com 1 Operating Instructions Bluetooth Handheld Scanner iSCAN2012D iSCAN21...

Страница 2: ...tation 8 4 System assembly 9 4 1 Assembly 1 description 9 4 2 Cable range in assembly 1 10 4 3 Assembly 2 description 10 4 4 Cable range in assembly 2 11 5 Step by step guide to installation and opera...

Страница 3: ...1PDF iSCAN211EXB iSCAN2XXCAB5 iSCAN2XXCAB6 iSCAN2XXCAB7 iSCAN2XXCAB8 iSCAN2XXCAB9 iSCAN2XXCAB10 iSCANPS1 iSCANPS2 iSCANPS3 iSCANPS4 iSCAN211B iSCAN211BNOBT iSCAN2XXCAB1 iSCAN2XXCAB2 iSCAN2XXBLP iSCAN2...

Страница 4: ...he Operating Instructions contain important information on functionality as well as safety rules If these are not heeded normal operations within hazardous areas cannot be guaranteed The notes contain...

Страница 5: ...uids temperatures outside of the specified range etc General statutory requirements or health and safety rules and accident prevention guidelines and environmental laws must be adhered to e g the Germ...

Страница 6: ...s or the use of procedures that differ from these instructions may result in a dangerous exposure to laser beams Class 2 lasers use a visible low voltage LED As with any source of bright light such as...

Страница 7: ...point 18 Middlewich CW10 0HU 3 2 Certification 3 3 Serial numbers Serial key Year of manufacture 2 numbers Serial number 4 numbers Example 16001 iSCAN211 and iSCAN211PDF II 2 G Ex ib IIC T4 II 2 G Ex...

Страница 8: ...wn RS232 TXD white GND brown UB yellow Nominal values of hazardous area base station maximum input voltage Ui 4 9 V maximum input current li 480 mA maximum input power Pi 1 25 W maximum internal induc...

Страница 9: ...ection cable s between power supply and a PC External connection cables Data cable USB 0 2 2 5 mm 4 wire RS232 0 2 2 5 mm 3 wire Power cable 0 2 2 5 mm 3 wire The handheld scanner and the power supply...

Страница 10: ...base or charging station is then operated in the non hazardous area Use an RS232 cable iSCAN2XXCAB1 or 2 or a USB cable iSCAN2XXCAB3 or 4 to connect the station directly to a power supply and a PC Th...

Страница 11: ...5000 Fax 44 0 845 277 4000 E mail info extronics com Web www extronics com 11 4 4 Cable range in assembly 2 RS232 iSCAN211B iSCAN211BNOBT iSCAN201B2D iSCAN201BNOBT 1 8 or 3 8m or optional with 4 5m o...

Страница 12: ...sen the screw to remove the lid Open the battery compartment After the screw has been loosened the removal of the lid requires a certain amount of force An iSCAN2XXBATT is required to operate the Blue...

Страница 13: ...iSCAN2XXCAB5 6 7 8 9 or 10 Insert the cable in the opening at the bottom of the base charging station If the cable has been inserted fully you can hear a click Check if the cable fits firmly Insert th...

Страница 14: ...bottom of the base charging station This connection is closed ex factory for a base charging station for hazardous areas To connect the base charging station in a non hazardous area the connection cab...

Страница 15: ...supply Caution Do not open enclosure in the hazardous area Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightene...

Страница 16: ...nner RS232 connection cable iSCAN101CAB1 2 Power supply iSCANPS1 12D 3 32D RJ45 Pin assignment Wire colours Definition Connection terminal power supply Definition 6 White TXD X9 RXD X10 GND X11 PE 4 B...

Страница 17: ...wer supply Caution Do not open enclosure in the hazardous area Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tigh...

Страница 18: ...scanner USB connection cable iSCAN101CAB3 4 Power supply iSCANPS2 4 RJ45 Pin assignment Wire colours Definition Connection terminal power supply Definition 2 Green D X9 D 10 White D X10 D X11 PE 4 Bla...

Отзывы: