Direct connection of base station without plug connection to the RS232 iSCANPS – connection with 
cable end sleeve: 

 

Pin assignment of scanner 

RS232 connection cable 

(iSCAN101CAB1, 2)

 

Power supply  

(iSCANPS1, 12D, 3, 32D)

 

 

RJ45 Pin 

assignment 

Wire 

colours 

Definition 

Connection 

terminal 

power supply 

Definition 

White 

TXD 

X9 

RXD 

 

 

 

X10 

GND 

 

 

 

X11 

PE 

Brown 

GND 

X12 

GND 

Yellow 

+UB 

X13 

+UB 

 

 

 

 

 

Intrinsically safe connection box 

of the

 

RS232 iSCANPS power supply 

after removal of the wires of the plug connection 

To fully operate the Bluetooth handheld scanner you will require the programming information 
contained in the manual published by SICK AG (www.SICK.com). 

Содержание iSCAN2012D

Страница 1: ...nt 18 Middlewich Cheshire UK CW10 0HU Tel 44 0 845 277 5000 Fax 44 0 845 277 4000 E mail info extronics com Web www extronics com 1 Operating Instructions Bluetooth Handheld Scanner iSCAN2012D iSCAN21...

Страница 2: ...tation 8 4 System assembly 9 4 1 Assembly 1 description 9 4 2 Cable range in assembly 1 10 4 3 Assembly 2 description 10 4 4 Cable range in assembly 2 11 5 Step by step guide to installation and opera...

Страница 3: ...1PDF iSCAN211EXB iSCAN2XXCAB5 iSCAN2XXCAB6 iSCAN2XXCAB7 iSCAN2XXCAB8 iSCAN2XXCAB9 iSCAN2XXCAB10 iSCANPS1 iSCANPS2 iSCANPS3 iSCANPS4 iSCAN211B iSCAN211BNOBT iSCAN2XXCAB1 iSCAN2XXCAB2 iSCAN2XXBLP iSCAN2...

Страница 4: ...he Operating Instructions contain important information on functionality as well as safety rules If these are not heeded normal operations within hazardous areas cannot be guaranteed The notes contain...

Страница 5: ...uids temperatures outside of the specified range etc General statutory requirements or health and safety rules and accident prevention guidelines and environmental laws must be adhered to e g the Germ...

Страница 6: ...s or the use of procedures that differ from these instructions may result in a dangerous exposure to laser beams Class 2 lasers use a visible low voltage LED As with any source of bright light such as...

Страница 7: ...point 18 Middlewich CW10 0HU 3 2 Certification 3 3 Serial numbers Serial key Year of manufacture 2 numbers Serial number 4 numbers Example 16001 iSCAN211 and iSCAN211PDF II 2 G Ex ib IIC T4 II 2 G Ex...

Страница 8: ...wn RS232 TXD white GND brown UB yellow Nominal values of hazardous area base station maximum input voltage Ui 4 9 V maximum input current li 480 mA maximum input power Pi 1 25 W maximum internal induc...

Страница 9: ...ection cable s between power supply and a PC External connection cables Data cable USB 0 2 2 5 mm 4 wire RS232 0 2 2 5 mm 3 wire Power cable 0 2 2 5 mm 3 wire The handheld scanner and the power supply...

Страница 10: ...base or charging station is then operated in the non hazardous area Use an RS232 cable iSCAN2XXCAB1 or 2 or a USB cable iSCAN2XXCAB3 or 4 to connect the station directly to a power supply and a PC Th...

Страница 11: ...5000 Fax 44 0 845 277 4000 E mail info extronics com Web www extronics com 11 4 4 Cable range in assembly 2 RS232 iSCAN211B iSCAN211BNOBT iSCAN201B2D iSCAN201BNOBT 1 8 or 3 8m or optional with 4 5m o...

Страница 12: ...sen the screw to remove the lid Open the battery compartment After the screw has been loosened the removal of the lid requires a certain amount of force An iSCAN2XXBATT is required to operate the Blue...

Страница 13: ...iSCAN2XXCAB5 6 7 8 9 or 10 Insert the cable in the opening at the bottom of the base charging station If the cable has been inserted fully you can hear a click Check if the cable fits firmly Insert th...

Страница 14: ...bottom of the base charging station This connection is closed ex factory for a base charging station for hazardous areas To connect the base charging station in a non hazardous area the connection cab...

Страница 15: ...supply Caution Do not open enclosure in the hazardous area Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightene...

Страница 16: ...nner RS232 connection cable iSCAN101CAB1 2 Power supply iSCANPS1 12D 3 32D RJ45 Pin assignment Wire colours Definition Connection terminal power supply Definition 6 White TXD X9 RXD X10 GND X11 PE 4 B...

Страница 17: ...wer supply Caution Do not open enclosure in the hazardous area Before operating the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tigh...

Страница 18: ...scanner USB connection cable iSCAN101CAB3 4 Power supply iSCANPS2 4 RJ45 Pin assignment Wire colours Definition Connection terminal power supply Definition 2 Green D X9 D 10 White D X10 D X11 PE 4 Bla...

Отзывы: